Panasonic NC-EH22P / NC-EH30P / NC-EH40P / NC-EH30PWTW / NC-EH40PWTW Service Manual ▷ View online
NC-EH22P
NC-EH30P
NC-EH40P
NC-EH30P
NC-EH40P
Service Manual
ORDER NO. PHAT070511C3
Specifi cations
Power Supply
NC-EH22P
NC-EH30P
NC-EH40P
Hong Kong Thailand Vietnam Malaysia Taiwan Hong Kong Thailand Vietnam Singapore Malaysia Taiwan Hong Kong Thailand Malaysia
220V
220V 220V 240V 110V 220V
220V 220V 230V
240V 110V 220V
220V 240V
Power
Consumption
(approx.)
Consumption
(approx.)
Rated
700W
Boiling
700W
Keep Warm
111W 111W 111W 132W 69W 111W 111W 111W 121W 132W 69W 111W 111W 132W
Average
power
consumption
during keep
warm
power
consumption
during keep
warm
98°C
40Wh
45Wh
49Wh
90°C
33Wh
39Wh
43Wh
80°C
27Wh
31Wh
35Wh
60°C
18Wh
21Wh
23Wh
Average power consumption per hour for keep warm status. (Conditions: Room temperature, water
temperature 20°C with rated water volume)
temperature 20°C with rated water volume)
Capacity (approx.)
2.2L
3.0L
4.0L
Dimensions (approx.) (W × D × H)
22.0 × 28.7 × 23.8 cm
22.0 × 28.7 × 27.5 cm
22.0 × 28.7 × 32.4 cm
Weight (approx.)
1.9kg
2.0kg
2.1kg
Thermal regulation
Boiling : Relay, thyristor
Warming : Thyristor
Rotating base
Can rotate 360° with the power cord
Thermal fuse
157°C
Power cord
Approx. 1 m
Hot water supply device specifi cations
Hot water supply method
Hot water supply method
Current volume adjustment range
54ml/sec (Constant)
Operation method
Push switch
Pump-lock
Electronic lock system (Locked in 10 sec. after switching “Dispense”)
Hot water pump Power consumption
1.5W (DC commutator motor)
Rated duration
3 minutes
Additional functions: Dechlorination, keep warm (98, 90, 80, 60), Energy saving timer 6 hours), Overheating protection, Lock/Unlock pad,
Citric acid cleaning
Citric acid cleaning
!
WARNING
Panasonic
Product Color
White (W), Pink (P), Beige (C)
Destination
Thailand, Taiwan, Hong Kong, Singapore, Malaysia and Vietnam
White (W), Pink (P), Beige (C)
Destination
Thailand, Taiwan, Hong Kong, Singapore, Malaysia and Vietnam
Sensor : Thermistor
NC-EH22_30_40P.indd 1
NC-EH22_30_40P.indd 1
1/14/08 9:36:14 AM
1/14/08 9:36:14 AM
- 2 -
NC-EH22P, EH30P, EH40P
WARNING
This indicates “the possibility of death or serious injury”.
CAUTION
This indicates “the possibility of injury or property loss”.
This symbol indicates caution to be careful.
This symbol indicates compulsory action that must be followed.
1 Cautions for safe repair work
To prevent accidents during repair work, injury or property loss to the users, safety instructions are described
below.
■ Degree of loss or potential for injury is classifi ed as follows.
■ Safety instructions are classifi ed with symbols as below, and explanations are described as follows.
(Below symbols are examples)
(Below symbols are examples)
After the repair, replace the original wiring layout.
Otherwise the lead wires may contact any rotating parts or adjacent components causing failure,
electric shock, or fi re.
electric shock, or fi re.
Be careful to avoid electric shock.
Disconnect power plug while repairing.
Caution for
electric shock
During repair service with power on,
such as for voltage measurement, be
careful to avoid electric shock around
charged battery portion or lead wire ter-
minals.
such as for voltage measurement, be
careful to avoid electric shock around
charged battery portion or lead wire ter-
minals.
ୃℂᬺోߩᵈᗧ
Disconnect
power plug
Disassemble, assemble and replace
parts after disconnecting the power
source. Failure may cause electric
shock or injury.
parts after disconnecting the power
source. Failure may cause electric
shock or injury.
Make sure to use specifi ed parts.
Make sure to use specifi ed parts if indicated with the symbol
! in circuit diagram or parts list.
WARNING
Wear gloves while disassembling, replacing or assembling.
Make sure to wear gloves while power is on to avoid injury from sharp metal edges or
electric shock during service work.
CAUTION
Contents
Page
1. Specifi cations .......................................................................................................................................................1
2. Cautions for safe repair work ...............................................................................................................................2
3. Failure diagnostics ...............................................................................................................................................3
4. Disassembly and Reassembly Instructions .........................................................................................................7
5. Schematic diagram ............................................................................................................................................14
6. Parts location and parts list ................................................................................................................................17
2. Cautions for safe repair work ...............................................................................................................................2
3. Failure diagnostics ...............................................................................................................................................3
4. Disassembly and Reassembly Instructions .........................................................................................................7
5. Schematic diagram ............................................................................................................................................14
6. Parts location and parts list ................................................................................................................................17
NC-EH22_30_40P.indd 2
NC-EH22_30_40P.indd 2
1/14/08 9:36:15 AM
1/14/08 9:36:15 AM
Water fi ll
-2.0-
-1.0-
-Min-
3.0
Panasonic
- 3 -
NC-EH22P, EH30P, EH40P
2. Failure diagnostics
Before starting failure diagnostics, check the operation
following the pot performance test modes described
below.
below.
2.1. Pot performance test mode
2.1.1. Boiling and keep warm test
Procedure
1. Pour approx. 1000 ml water into the container.
2. Turn the power on.
3. Push Select pad and set 98.
2. Turn the power on.
3. Push Select pad and set 98.
The markings in the illustration mean as follows.
● Continuous illumination
Flashing
Performance
1. The reboil lamp illuminates, and the boiling
operation starts. (LCD indicates a temperature
higher than 5°C rounded to every 5°C.)
higher than 5°C rounded to every 5°C.)
2. After 9 minutes, vacuum keep warm lamp
illuminates and switches to the keep warm
mode. (Keep warm mode)
mode. (Keep warm mode)
÷ After approx. 9 minutes, the 100 keep warm lamp
changes to 98.
÷ After approx. 3 minutes, the 90 keep warm lamp
changes to 98.
÷ After approx. 3 minutes, the 80 keep warm lamp
changes to 98.
÷ After approx. 3 minutes, the 60 keep warm lamp
changes to 98.
÷ Required time for the water temperature to increase
to the set temperature
98 keep warm: approx. 1 to 2 minutes
90 keep warm: approx. 1 to 2 hours
80 keep warm: approx. 2.5 to 4.5 hours
60 keep warm: approx 8.5 to 13 hours
(in conditions of room temperature of 20°C with full
90 keep warm: approx. 1 to 2 hours
80 keep warm: approx. 2.5 to 4.5 hours
60 keep warm: approx 8.5 to 13 hours
(in conditions of room temperature of 20°C with full
water volume)
Water level gauge
Approx. 1000 ml.
Long Boil
Reboil
Select
Cleaning
(Press 3s)
(Press 3s)
Pour
out
6h Timer
80
98
60
90
Unlock
Lock
Long Boil
Reboil
Select
Cleaning
(Press 3s)
(Press 3s)
Pour
out
6h Timer
80
98
60
90
Unlock
Lock
NC-EH22_30_40P.indd 3
NC-EH22_30_40P.indd 3
1/14/08 9:36:17 AM
1/14/08 9:36:17 AM
- 4 -
NC-EH22P, EH30P, EH40P
Unlock
Lock
Unlock
Lock
Unlock
Lock
Unlock
Lock
6h Timer
80
98
60
90
Long Boil
Reboil
Select
Cleaning
(Press 3s)
(Press 3s)
Pour
out
6h Timer
80
98
60
90
6h Timer
80
98
60
90
6h Timer
80
98
60
90
Long Boil
Reboil
Select
Cleaning
(Press 3s)
(Press 3s)
Pour
out
Performance
When Reboil pad is pressed once.
1. The reboil lamp illuminates and reboil starts.
1. The reboil lamp illuminates and reboil starts.
Indication on LCD is as follows.
2.
After 1 minute, vacuum keep warm lamp
illuminates. Indication on LCD is as follows.
illuminates. Indication on LCD is as follows.
Performance
When the Reboil pad is pressed twice (for
dechlorination)
dechlorination)
1. Reboil lamp illuminates and boiling starts (LCD
changes to 100 in the process). Indication on
LCD is as follows.
LCD is as follows.
2. After 7 minutes, the vacuum keep warm lamp
illuminates. Indication on LCD is as follows.
2.1.2. Reboil and keep warm test
Procedure
1. Switch to keep warm with 98 setting.
2. Press the Reboil pad once or twice.
2. Press the Reboil pad once or twice.
Long Boil
Reboil
Select
Cleaning
(Press 3s)
(Press 3s)
Pour
out
Press this pad.
Long Boil
Reboil
Select
Cleaning
(Press 3s)
(Press 3s)
Pour
out
Long Boil
Reboil
Select
Cleaning
(Press 3s)
(Press 3s)
Pour
out
6h Timer
80
98
60
90
Unlock
Lock
NC-EH22_30_40P.indd 4
NC-EH22_30_40P.indd 4
1/14/08 9:36:18 AM
1/14/08 9:36:18 AM