114
4.3.10
Information Codes: 030, 031 (Document Jam)
START
END
Yes
No
Is the document path blocked?
Remove the blockage.
Yes
No
Does the Tx Motor rotate?
1. Replace the Tx Motor.
2. Replace the FCB PCB.
2. Replace the FCB PCB.
Yes
No
Does the document feed into the
unit?
unit?
Check all gears and rollers.
Does the problem still occur?
Yes
Yes
No
No
Does the output of CN7, pin2,
on the FCB PCB, vary between 0
and +5V when a document is set
and removed?
on the FCB PCB, vary between 0
and +5V when a document is set
and removed?
Check the connection of CN7
on the FCB PCB and CN31
on the SNS PCB.
on the FCB PCB and CN31
on the SNS PCB.
Replace the SNS PCB.
115
4.3.11
Information Code: 630 (Dialing Error)
START
END
END
Yes
No
Is there a dial tone when
MONITOR button is pressed?
MONITOR button is pressed?
1. Connect the telephone line
correctly.
2. Check the telephone line.
correctly.
2. Check the telephone line.
Yes
No
Is the remote machine busy?
Can the unit dial the reference
unit?
unit?
No
1. Check all connectors.
2. Replace the FCB PCB.
2. Replace the FCB PCB.
1. The remote machine is defective.
2. Telephone line quality is poor.
(Refer to Sect. 4.6.)
(Refer to Sect. 4.6.)
Press the REDIAL button to retry
connection.
connection.
Yes
116
4.3.12
Information Codes: 403, 411, 414, 415 (Polling Operator Trouble)
403,411,414
START
END
END
Review the polling operation
referring to the User's Guide.
referring to the User's Guide.
Yes
Yes
No
Does the remote side have
polling transmission capability?
polling transmission capability?
No
Ask the remote side to set their
unit for polling operation.
unit for polling operation.
Is the remote side set to polling
transmission (Polled) Mode?
transmission (Polled) Mode?
Check the password between the
two units to ensure it matches.
two units to ensure it matches.
415
START
END
Inform the remote side (receiving
side) that their machine does not
have polling transmission
capability.
side) that their machine does not
have polling transmission
capability.
Polling communication with 4-digit password is not an ITU-T / CCITT Standard feature.
If the transmitter and receiver are of different manufacturers, polling communication with password
If the transmitter and receiver are of different manufacturers, polling communication with password
may not
be possible.
117
4.4
Printed Copy Quality Problems
4.4.1
Black Copy
START
No
Yes
Is the printout in Service Mode 3
normal?
normal?
Check the Scanner mechanism.
Is the HVPS normal?
Is the LPC PCB normal?
Is the Toner Cartridge
operational?
operational?
Replace the Toner Cartridge.
1. Check all connectors and
voltages on the HVPS.
2. Check the contacts between HVPS
and Toner Cartridge.
3. Replace the HVPS.
Yes
No
Yes
Yes
No
No
1. Check all connectors and
voltages on the LPC PCB.
2. Replace the LPC PCB.
END