33
2.2.4.
Transmit Guide (301) Assembly, Scanning Glass (308)
(7) Remove 5 Screws (19).
(8) Remove the Control Panel Chassis Assembly, and 
Front Panel.
Note:
If noise occurs while scanning, clean the Roller Shaft 
2
 (235), and the Feed Pinch Roller (236) shaft hole 
with isopropyl alcohol.
(9) Remove 15 Screws (19).
(10) Disconnect Connector CN50 on the PNL1 PC 
Board.
(11) Release 2 Latch Hook.
(12) Remove the PNL1 PC Board (1004).
(1) Remove the Left Cover (103), Right Cover (102), 
and Front Cover (104) (Refer to 2.2.2.).
(2) Remove the Control Panel Unit (Refer to 2.2.3.).
(3) Release the Harnesses from the clamps.
(4) Remove 4 Screws (19).
(5) Disconnect 4 Connectors (CN1, 3, 5, and 7) on the 
SC PC Board.
(6) Remove the Transmit Guide (301) Assembly.
(7) Carefully release the Latch Hook using a Blade-tip 
Screwdriver.
(8) Remove the Scanning Glass (308).
(4) x 4
(6)
(5)
(3)
(7)
(8)
34
2.2.5.
Stamp Assembly, Stamp Solenoid (327)
<Cleaning Scanning Glass>
(1) Open the Control Panel Unit.
(2) Clean the Scanning Glass (308) with a soft cloth, 
dabbed in isopropyl alcohol.
<Cleaning Feed Roller, Eject Roller, ADF Roller>
(1) Open the Control Panel Unit.
(2) Clean the Feed Roller (302), Eject Roller (303), and 
ADF Roller (331) with a soft cloth, dabbed in 
isopropyl alcohol.
(1) Remove the Transmit Guide (301)  Assembly 
(Refer to 2.2.4.).
(2) Remove the Stamp Assembly (325, and 326).
(3) Remove 1 Screw (19).
(4) Remove the Stamp Solenoid (327).
(1)
(2)
(1)
(2)
(2)
(2)
(2)
(3)
(4)
35
2.2.6.
Eject Roller (303)
(1) Remove the Transmit Guide (301) Assembly 
(Refer to 2.2.4.).
(2) Remove the Stamp Assembly (325, and 326) 
(Refer to 2.2.5.).
(3) Release 2 Latch Hooks.
(4) Remove the Ground Plate (317).
(5) Release the Latch Hook by using a small Blade-tip 
Screwdriver.
(6) Remove 2 D25F Drive Gears (332).
(7) Remove D17 Gear (313), and D50 Gear (314).
(8) Remove 2 P6C Bushings (342).
(9) Remove the Roller Wire Spring (343).
Caution:
Reinstall the Roller Wire Spring (343) as illustrated.
(3)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
Roller Spring
36
2.2.7.
Transmit Motor (324)
(10) Remove 2 P6A Bushings (316).
(11) Remove the Eject Roller (303).
(1) Remove the Transmit Guide (301) Assembly 
(Refer to 2.2.4.).
(2) Remove the Stamp Assembly (325, and 326) 
(Refer to 2.2.5.).
(3) Disconnect the Connector (1020) from the Transmit 
Motor (324).
(4) Remove the ADF Gear (305), and ADF Angular 
Shaft (338).
Caution:
When removing the ADF Gear, rotate the Transmit 
Motor Gear by hand until the Gear Latch Hook can be 
seen from the inside, under the Transmit Motor.  Push 
down on the Latch Hook to release the ADF Gear.
(5) Remove 2 Screws (19).
(6) Remove the Transmit Motor (324).
Caution:
Reinstall the Transmit Motor (324) as illustrated.
Caution:
Before reassembling, apply EM-50L Grease to the 
Gear Posts as illustrated.
(10)
(11)
(3)
(4)
(5)
(6)
Page of 127
Display