DOWNLOAD Panasonic KX-MB2051RUB / KX-MB2061RUB Service Manual ↓ Size: 22.44 MB | Pages: 127 in PDF or view online for FREE

Model
KX-MB2051RUB KX-MB2061RUB
Pages
127
Size
22.44 MB
Type
PDF
Document
Service Manual
Brand
Device
Fax / MULTI-FUNCTION PRINTER
File
kx-mb2051rub-kx-mb2061rub.pdf
Date

Panasonic KX-MB2051RUB / KX-MB2061RUB Service Manual ▷ View online

13
KX-MB2051RUB / KX-MB2061RUB
4.2.4.
Cordless Handset
14
KX-MB2051RUB / KX-MB2061RUB
5 Features
5.1.
General Features
General
• Help function
1. FEATURE LIST
2. PHONEBOOK
3. TAM OPERATION
4. FAX RECEIVING
5. CALLER ID
• LCD (Liquid Crystal Display) readout
Flat-Bed Multifunction Laser Fax
Output tray (approx. 100 sheets)
Letter/A4/Legal, G3 compatible
Automatic document feeder (20 sheets)
Quick scan
Resolution: Standard/Fine/Super fine/Photo (64 level).
STANDARD: For printed or typewritten originals with normal-
sized characters.
FINE: For originals with small printing.
SUPER FINE: For originals with very small printing.
PHOTO: For originals containing photographs, shaded draw-
ing, etc.
Broadcast 
• 250-sheet paper capacity (60 g/m
2
 ~ 75 g/m
2
)
Large Memory... Performed by DRAM
Approx. 150 pages of memory transmission
Approx. 110 pages of memory reception
Enhanced Copier Function
Multi-copy function (up to 99 copies)
Enlargement and reduction
64-Level halftone
Integrated Telephone System
• On-hook dialing
• Redialing function
• The Base unit provide a phonebook (100 items)
• The cordless handset provide a phonebook (100 items)
• Caller  ID
Digital Answering System
• Voice Time / Day Stamp
• 30-Minutes of recording time
DECT Cordless
• Fax activation from cordless handset
• Battery performance:
18 hours max (In continuous use) and 170 hours max (not in
use (standby mode))
5.2.
Hardware Requirements for Multi-Function Software
To use Multi-Function Station on your computer, the following are required:
Operating System:
Windows 2000 / Windows XP / Windows Vista / Windows 7
CPU:
Windows 2000: Pentium
®
   or higher processor
Windows XP: Pentium   or higher processor
Windows Vista/Windows 7: Pentium 4 or higher processor
RAM:
Windows 2000/Windows XP: 128 MB (256 MB or more recommended)
Windows Vista: 512 MB (1GB or more recommended)
Windows 7: 1 GB (2GB or more recommended)
Other Hardware:
CD-ROM drive
Hard disk drive with at least 200 MB of available space
USB interface
LAN interface (10Base-T/100Base-TX)
Other:
Internet Explorer
®
 5.0 or later
Audio output
Warning:
• To assure continued emission limit compliance;
- use only shielded USB cable (Example: Hi-Speed USB 2.0 certified cable).
- use only shielded LAN cable (category 5 straight cable).
• To protect the unit, use only shielded USB cable in areas where thunderstorms occur.
• To use Easy Print Utility on your computer, the following are required:
- Windows 2000 Service Pack 4 and Security update for Windows 2000 (KB835732). Install KB835732 from Microsoft down-
load site before installing Easy Print Utility.
- Windows XP Service Pack 2 or later.
15
KX-MB2051RUB / KX-MB2061RUB
6 Technical Descriptions
6.1.
Connection Diagram
HOOK  SW
1
2
3
4
5
6
1
2
3
4
5
6
CN55
1
2
3
4
5
6
1
2
3
4
5
6
CN940
HSSP-
6
HSSP+
5
GND
4
HSMIC -
3
2
No
HOOK
HSMIC+
1
NAME
NAME
No 
HSSP-
6
HSSP+
5
GND
4
HSMIC -
3
2
No
HOOK
HSMIC+
1
NAME
NAME
No 
CN55
1
2
3
4
CN941
HSMIC+
4
HSSP-
3
2
No
HSMIC -
HSSP+
1
NAME
NAME
No 
HSMIC+
4
HSSP-
3
2
No
HSMIC -
HSSP+
1
NAME
NAME
No 
CN941
HA
NDSE
T
HANDSET
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
1
2
1
2
1
2
1
2
3
1
2
3
1
2
3
4
5
6
7
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
1   4
2   3
1   4
2   3
4
2
No
D-
VBUS
1
GND
D+
3
NAME
NAME
No 
4
2
No
D-
VBUS
1
GND
D+
3
NAME
NAME
No 
CN500
CN501
CN502
CN506
CN507
CN514
CN505
CN504
CN510
1
2
3
4
1
2
3
4
CN509
CN511
1
2
3
4
CN701
1
2
3
4
CN701
1
2
3
4
CN700
1
2
3
4
CN700
CN300
CN101
CN100
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
CN200
CN750
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
CN508
MAIN
BOARD
DC  MOTOR  UNIT
HVPS
SMPS
OPERATION  PANEL  BOARD
LCD
LSU
MAIN
MOTOR
REG
REGISTER
SOLENOID
PICKUP 
SOLENOID
TO
TELEPHONE
LINE
TO
EXTERNAL
TELEPHONE
TO  
PC/USB
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
CN300
CN2
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
10
CN1
HTRCTL
7V
DG
DG
DG
24V
24V
1
2
3
4
5
6
7
1
2
3
4
5
6
7
24V
8
CN101
1
2
1
2
CN2
CVR
HVERR
TRS
CHG
DEV
GND
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7
CN1
HEAT
LAMP
COVER  OPEN SW
TRA
OPC
DEV
GRID
CHG
DG
FANDET1
FANON1
DG
DG
PICK
PO
LC
LK
XR
E
A
D
Y
PO
LO
N
DG
24V
XH
S
Y
N
C
DG
5V
XA
PC
XLD
E
N
XV
ID
E
O
DG
24V
24V
DG
DG
LD
SS
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
CL
K
BRAK
E
DC  FAN1
(Left )
TRANSCRIPTION
ROLLER
OPC
DRUM
DRUM  UNIT
SCOROTRON
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
TH
R
M
KS
T
A
R
T
KT
X
D
KS
C
L
K
OP
E
R
S
T
DG
5V
BU
Z
Z
ER
TH
R
M
KS
T
A
R
T
KT
X
D
KS
C
L
K
OP
E
R
S
T
DG
5V
BU
Z
Z
ER
DB
7
DB
6
DB
5
DB
4
E
R / W
RS
V0
VD
D
VS
S
DEVELOPING
ROLLER
TONER  SUPPLY
ROLLER
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
TONER  
SENSOR
CN64
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
CN67
CN63
DG
PICK
DG
FANDET2
FANON2
PICKUP  
SENSOR
SW50
1
2
3
1
2
3
FA
N
D
E
T
2
DG
F
A
NO
N2
IC51
1
2
3
4
1
2
3
4
CN66
1
2
3
4
1
2
3
4
CN50
5V
REG
PTO
P
DG
REGISTER
SENSOR
PTOP  
SENSOR
PS51
PS52
HEAT  LAMP
THERMOSTAT
THERMOSTAT
THERMISTOR
1
2
3
4
1
2
3
4
CN65
1
2
3
4
PS50
EXIT SENSOR
CN53
1
2
3
1
2
3
CN52
THRM1
DG
FUSER
UNIT
VARISTOR  
BOARD
8
RCT
7
RD-
6
5
TCT
4
RD+
3
2
No
TD -
TD+
1
NAME
NAME
No 
8
RCT
7
RD-
6
5
TCT
4
RD+
3
2
No
TD -
TD+
1
NAME
NAME
No 
b1
6
S(W) / B2
5
b / B1
4
a / A1
3
2
No
E(G) / A2
a1
1
NAME
NAME
No 
b1
6
S(W) / B2
5
b / B1
4
a / A1
3
2
No
E(G) / A2
a1
1
NAME
NAME
No 
CN100
a1
6
E(W)
5
a / A1
4
b / B1
3
2
No
S(W)
b1
1
NAME
NAME
No 
a1
6
E(W)
5
a / A1
4
b / B1
3
2
No
S(W)
b1
1
NAME
NAME
No 
CN101
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
HSSP+
HSSP-
MIC+
MIC -
HOOK
GND
SP-
SP+
HSSP+
HSSP-
MIC+
MIC -
HOOK
GND
SP-
SP+
CN58
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
CN70
CN71
1
2
1
2
CN57
Speaker
SP+
SP-
ADF
MOTOR
A
B
XA
XB
READ
POSITION
SENSOR
DOCUMENT  
SENSOR
PS53
PS54
1
2
3
4
CN56
3.3V
RP
S
DO
C
U
DG
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
1
2
3
4
CN750
CN59
CN60
1
2
3
4
CN62
1
2
3
4
CN62
FB   
MOTOR
A
B
XA
XB
2    1
12   11
2    1
12   11
CN61
CISMODULE
LED_G
10
VLED
9
CLK
8
DG
7
SI
6
CNT
5
VREF
4
3.3V
3
12
2
No
DG
SIG
1
LED_B
LED_R
11
NAME
NAME
No 
LED_G
10
VLED
9
CLK
8
DG
7
SI
6
CNT
5
VREF
4
3.3V
3
12
2
No
DG
SIG
1
LED_B
LED_R
11
NAME
NAME
No 
CN61
FB  RELAY 
BOARD  
DC  FAN 2
(Right )
CN 51
CR_A
CR_B
CR_XA
CR_XB
GND
3.3V
VREF
SI
GND
CLK
LED_G
LED_R
LED_B
SIG
GND
VLED
1
3
5
2
4
6
1
3
5
2
4
6
1
3
5
2
4
6
1
3
5
2
4
6
TO
PC/LAN
1
3
5
7
2
4
6
8
TH
R
M
1
5V
PO
U
T
GN
D
PO
U
T
5V
TH
R
M
1
GN
D
FA
N
O
N
2
FA
N
D
E
T
2
PI
C
K
TN
R
PTO
P
REG
1
2
1
2
CN1
LIVE
NEUTRAL
SW1
8
8
24V
NC
1
2
3
1
2
3
CN69
CIS HOME 
SENSOR
POWER SW
AC INLET
PS55
CIS HOME
GND
LED
1
2
3
1
2
3
CN68
CIS HOME
13
13
KX-MB2061 ONLY
16
KX-MB2051RUB / KX-MB2061RUB
6.2.
General Block Diagram
MAIN UNIT
SOC (IC300)
This custom IC is used for general MFP operations.
ROM (IC402)
This 8MB FLASH ROM contains all of the program instructions on the unit operations.
And support the backup of user setting and FAX receive data. 
SYNCHRONOUS DYNAMIC RAM (IC400)
This 256Mbit SDRAM is used for CPU work and receiving memory and page memory.
POWER SUPPLY
DC-DC converters generate 3.3V and 1.2V for system power.
Regurator generates 5V for peripheral devices.
TEL/FAX I/F
Composed of ITS circuit and NCU circuit.
BBIC (Base Band IC): IC902
Handling all the audio, signal and data processing needed in a DECT base unit
Controlling the DECT specific physical layer and radio section (Burst Module Controller section)
ADPCM codec filter for speech encoding and speech decoding (DSP section)
Echo-cancellation and Echo-suppression (DSP section)
Any tones (tone, sidetone, ringing tone, etc.) generation (DSP section)
DTMF receiver (DSP section)
Clock Generation for RF Module
ADC, DAC, timer, and power control circuitry
All interfaces (ex: RF module, EEPROM, LED, Analog Front End, etc.)
RF Module: IC905
PLL Oscillator
Detector
Compress/Expander
First/Second Mixer
Amplifier for transmission and reception
FLASH MEMORY: IC903
Voice Prompt (TAM) D/L (DownLoad) Area
Programming for BBIC (IC902)
EEPROM: IC904
Temporary operating parameters (for RF, etc.)
1)
CPU
ARM9 operating at 250MHz.
2)
SDRAM Controller
Controls SDRAM Memory.
3)
USB Controller with PHY
Apply to USB2.0 HS
4)
Scanner I/F
Controls the CIS and AFE, and process the scan images.
5)
LSU I/F
Controls the polygon motor and outputs the VIDEO signal to LSU.
6)
MOTOR I/F
Controls the DC motor and Stepping Motor.
7)
FAN I/F
Controls FAN MOTOR and detect the rotation of FAN MOTOR.
8)
OPERATION PANEL I/F
Serial interface with Operation Panel.
9)
SENSOR I/F
Detects the sensor signal.
10) I/O PORT
I/O Port Interface.
11)
A/D, D/A converter
Sends beep tones, etc.
Convert the analog signal to the digital signal.
12) RTC
Real time clock.
13) MODEM
Performs the modulation and the demodulation for FAX communication.
14) Analog Front End I/F
Controls the DAA device for TEL/FAX function. 
15) LAN Controller
Ethernet Control.
Page of 127
Display