6. Explanation of Technology
a. G3 Communication Signals (T. 30 Binary Process)
For G3 facsimile communication, this is the procedure for exchanging control signals between the sending and receiving
machines both before and after transmission of image signals.
Control signals at 300 bps FSK are: 1850 Hz...0, 1650Hz...1.
An example of the binary process in G3 communication is shown below.
Explanation of Signals
Control signals are comprised mainly of 8-bit identification signals and of the data signals added to them. Data signals are
added to DIS and DCS signals.
Signal.....DIS (Digital Identification Signal)
Identification Signal Format.....00000001
Function:
Notifies the capacity of the receiving unit. The added data signals are as follows.
125
KX-FT76RU-B
(Example)
Bit No.
DIS/DTC
DCS
1
Transmitter - T.2 operation
2
Receiver - T.2 operation
Receiver - T.2 operation
3
T.2 IOC = 176
T.2 IOC = 176
4
Transmitter - T.3 operation
5
Receiver - T.3 operation
Receiver - T.3 operation
6
Reserved for future T.3 operation features.
7
Reserved for future T.3 operation features.
8
Reserved for future T.3 operation features.
9
Transmitter - T.4 operation
10
Receiver - T.4 operation
Receiver - T.4 operation
11, 12
(0, 0)
(0, 1)
(1, 0)
(1, 1)
Data signaling rate
V.27 ter fall back mode
V.27 ter
V.29
V.27 ter and V.29
Data signaling rate
2400 bit/s, V.27 ter
4800 bit/s, V.27 ter
9600 bit/s, V.29
7200 bit/s, V.29
13
Reserved for the new modulation system.
14
Reserved for the new modulation system.
15
Vertical resolution = 7.7 line/mm
Vertical resolution = 7.7 line/mm
16
Two-dimensional coding capability
Two-dimensional coding
17, 18
(0, 0)
(0, 1)
(1, 0)
(1, 1)
Recording width capabilities
1728 picture elements along scan line length of
215 mm ± 1%
1728 picture elements along scan line length of
215 mm ± 1% and
2048 picture elements along scan line length of
255 mm ± 1% and
2432 picture elements along scan line length of
303 mm ± 1%
1728 picture elements along scan line length of
215 mm ± 1% and
2048 picture elements along scan line length of
255 mm ± 1%
Invalid
Recording width
1728 picture elements along scan line length of
215 mm ± 1%
2432 picture elements along scan line length of
303 mm ± 1%
2048 picture elements along scan line length of
255 mm ± 1%
Invalid
19, 20
(0, 0)
(0, 1)
(1, 0)
(1, 1)
Maximum recording length capability
A4 (297 mm)
Unlimited
A4 (297 mm) and B4 (364 mm)
Invalid
Maximum recording length
A4 (297 mm)
Unlimited
B4 (364 mm)
Invalid
Signal.....DCS (Digital Command Signal)
Identification Signal Format.....X1000001
Function:
Notifies the capacity of the receiving machine obtained at DIS and announces the transmission mode of the sender. The added
data signals are as follows.
(Example)
Bit No.
DIS/DTC
Standard setting
DCS
21, 22, 23
(0, 0, 0)
(0, 0, 1)
(0, 1, 0)
(1, 0, 0)
(0, 1, 1)
(1, 1, 0)
(1, 0, 1)
(1, 1, 1)
Minimum scan line time capability of the receiver
20 ms at 3.85 l/mm: T7.7 = T3.85
40 ms at 3.85 l/mm: T7.7 = T3.85
10 ms at 3.85 l/mm: T7.7 = T3.85
5 ms at 3.85 l/mm: T7.7 = T3.85
10 ms at 3.85 l/mm: T7.7 = 1/2 T3.85
20 ms at 3.85 l/mm: T7.7 = 1/2 T3.85
40 ms at 3.85 l/mm: T7.7 = 1/2 T3.85
0 ms at 3.85 l/mm: T7.7 = T3.85
Minimum scan line time
20 ms
40 ms
10 ms
5 ms
0 ms
24
Extend field
1
Extend field
25
2400 bit/s handshaking
0
2400 bit/s handshaking
26
Uncompressed mode
0
Uncompressed mode
27
Error correction mode
0
Error correction mode
28
Set to "0".
0
Frame size 0 = 256 octets 1 = 64 octets
29
Error limiting mode
0
Error limiting mode
30
Reserved for G4 capability on PSTN
0
Reserved for G4 capability on PSTN
31
Unassigned
0
32
Extend field
1
Extend field
33
(0)
(1)
Validity of bits 17, 18
Bits 17, 18 are valid
Bits 17, 18 are invalid
0
Recording width
Recording width indicated by bits 17, 18
Recording width indicated by this field bit
information
126
KX-FT76RU-B
Bit No.
DIS/DTC
Standard setting
DCS
34
Recording width capability 1216 picture elements along
scan line length of 151 ± mm 1%
0
Middle 1216 elements of 1728 picture elements
35
Recording width capability 864 picture elements along
scan line length of 107 ± mm 1%
0
Middle 864 elements of 1728 picture elements
36
Recording width capability 1728 picture elements along
scan line length of 151 ± mm 1%
0
Invalid
37
Recording width capability 1728 picture elements along
scan line length of 107 ± mm 1%
0
Invalid
38
Reserved for future recording width capabilities.
0
39
Reserved for future recording width capabilities.
0
40
Extend field
1
Extend field
41
Semi super time / mm
1
42
Semi super time / mm
0
43
Super time
0
44
Inch
0
45
mm
1
46
MSC/SF
0
47
Select Polling
0
48
EXT
0
Note 1 - Standard facsimile units conforming to T.2 must have the following capability: Index of cooperation (IOC)=264.
Note 2 - Standard facsimile units conforming to T.3 must have the following capability: Index of cooperation (IOC)=264.
Note 3 - Standard facsimile units conforming to T.4 must have the following capability: Paper length=297 mm.
Signal
Identification Signal Format
Function
Training 1
———————
A fixed pattern is transmitted to the receiving side at a speed
(2400 to 9600 bps) designated by DCS, and the receiving side
optimizes the automatic equalizer, etc., according to this signal.
TCF
(Training Check)
———————
Sends 0 continuously for 1.5 seconds at the same speed as the
training signal.
CFR
(Confirmation to Receive)
X0100001
Notifies the sending side that TCF has been properly received. If
TCF is not properly received, FTT (Failure To Train) X0100010 is
relayed to the sender. The sender then reduces the transmission
speed by one stage and initiates training once again.
Training 2
———————
Used for reconfirming the receiving side like training 1.
Image Signal
Refer to the next page.
———————
RTC
(Return to Control)
———————
Sends 12 bits (0...01 × 6 times) to the receiver at the same speed
as the image signal and notifies completion of transmission of the
first sheet.
EOP
(End of Procedure)
X1110100
End of one communication
MCF
(Message Confirmation)
X0110001
End of 1 page reception
DCN
(Disconnect)
X1011111
Phase E starts.
MPS
(Multi-Page Signal)
X1110010
Completion of transmission of 1 page. If there are still more
documents to be sent, they are output instead of EOP. After MCF
reception, the sender transmits an image signal of the second
sheet.
PRI-EOP
(Procedural Interrupt-EOP)
X1111100
If there is an operator call from the sender, it is output after RTC.
PIP
(Procedural Interrupt Positive)
X0110101
This is output when an operator call is received.
127
KX-FT76RU-B
b. Redundancy Compression Process Coding Mode
This unit uses one-dimensional MH format.
128
KX-FT76RU-B
Page of 127
Display

Panasonic KX-FT76RU-B Service Manual ▷ Download