37
KX-FLB883RU
6.8.2.
Flat Torque 1-2 Phase Excitation (Half Step)
1. Timing chart
2. Wave form
38
KX-FLB883RU
6.8.3.
W 1-2 Phase Excitation (Quarter Step)
1. Timing chart
2. Wave form
39
KX-FLB883RU
6.8.4.
Drive Mode of FB and ADF Motor
Correspondent table of operation
6.9.
FAN Motor Section
These FAN are used to radiate the heat inside of the unit.
6.9.1.
Right Side FAN (FAN1)
When the output of pin AN30 of IC300 becomes high level or pulse, Right side FAN (FAN1) is activated.
During the FAN rotation, the pulse signal is output from pin 2 of FAN1 and input to pin L34 of IC300.
When this pulse is stopped, it is judged that FAN error occurred.
40
KX-FLB883RU
6.9.2.
Left Side FAN (FAN2)
When the output of pin AP31 of IC300 becomes high level or pulse, Left side FAN (FAN2) is activated.
During the FAN rotation, the pulse signal is output from pin 2 of FAN2 and input to pin G33 of IC300.
When this pulse is stopped, it is judged that FAN error occurred.
6.9.3.
FAN Control
This unit is equipped with two FANs to prevent the developing devices from overheating during printing.
The FAN rotates at high speed (Approx. 3000rpm) while printing (controlling the developing devices).
After printing is finished, FAN rotates at low speed (Approx.2200rpm) while predetermined period.
1. Full speed control
To rotate the FANs with full speed, constant high level are output from AN30 and AP31 of IC300. Then Q512/Q510 and Q519/
Q520 are all turned on. So 24V are output from collectors of Q510 and Q520. Since each FAN consumes approx. 0.1A,
approx. 4V is reduced through R525 and R530. Then approx. 20V are supplied to each FANs.
2. Half speed control
To rotate the FANs with half speed, pulse signals are output from AN30 and AP31 of IC300. Then all Q512/Q510 and Q519/
Q520 repeat ON and OFF according to the pulse duty (30KHz/12.5%). These pulses are integrated by R525/C515 and R530/
C518 and converted to DC voltage. So approx. 12V are supplied to each FANs.
Pin No.
Level
FAN operation mode
IC300 AP31
High
Left side FAN Full speed
Pulse
Left side FAN halfl speed
Low
Left side FAN stop
IC300 AN30
High
Right side FAN Full speed
Pulse
Right side FAN Half speed
Low
Right side FAN stop