29
KX-FLB813RU
4. Concerning Transmission Time
Transmission Time   =    Control Time  +    Image Transmission Time     +    Hold Time
Transmission time consists of the following.
Control time:
This is time at the start of transmission when the functions at the sending and receiving sides are confirmed, the 
trans-
mission mode is established, and transmission and reception are synchronized.
Image transmission time:
This is the time required for the transmission of document contents (image data). In general, this time is recorded  in  the
catalog, etc.
Hold time:
This is the time required after the document contents have been sent to confirm that the document was actually sent, and
to check for telephone reservations and/or the existence of continuous transmission.
5. Facsimile Standards
6. Explanation of Communication and Compression Technology
a. G3 Communication Signals (T. 30 Binary Process) 
For G3 Facsimile communication, this is the procedure for exchanging control signals between the sending and receiving
 
Item
Telephone Network Facsimile
G3 Machine
Connection Control Mode
Telephone Network Signal Mode
Terminal Control Mode
T. 30 Binary
Facsimile Signal Format
Digital
Modulation Mode
PSK (V. 27 ter) or QAM (V. 29) or TCM (V.17)
Transmission Speed
300 bps (Control Signal)
 
2400, 4800, 7200, 9600, 12000, 14400 bps (FAX Signal)
Redundancy Compression
 
Process
 
(Coding Mode)
1 dimension: MH Mode
 
2 dimension: MR Mode (K=2.4)
 
3 dimension: MMR Mode (K=
)
Resolution
Main Scan: 8 pel/mm
 
Sub Scan: 3.85, 7.7l/mm, 15.4l/mm
Line Synchronization Signal
EOL Signal
1 Line Transmission Time
 
[ms/line]
Depends on the degree of data reduction.
 
Minimum Value: 10, 20, 0
 
Can be recognized in 40ms.
30
KX-FLB813RU
machines both before and after transmission of image signals.
Control signals at 300 bps FSK are: 1850 Hz...0, 1650Hz...1. 
An example of a binary process in G3 communication is shown below.
Explanation of Signals 
Control signals are comprised mainly of 8-bit identification signals and the data signals added to them. Data signals are
added to DIS and DCS signals.
Signal.....DIS (Digital Identification Signal) 
Identification Signal Format.....00000001
Function:
Notifies the capacity of the receiving unit. The added data signals are as follows.
Signal.....DCS (Digital Command Signal) 
Identification Signal Format.....X1000001
Example
 (Some models do not support the following items.):
Bit No.
DIS/DTC
DCS
1
Transmitter --- T.2 operation
2
Receiver --- T.2 operation
Receiver --- T.2 operation
3
T.2 IOC = 176
T.2 IOC = 176
4
Transmitter --- T.3 operation
5
Receiver --- T.3 operation
Receiver --- T.3 operation
6
Reserved for future T.3 operation features
7
Reserved for future T.3 operation features.
8
Reserved for future T.3 operation features.
9
Transmitter --- T.4 operation
10
Receiver --- T.4 operation
Receiver --- T.4 operation
31
KX-FLB813RU
11,12,13,14
 
0,0,0,0
 
0,1,0,0
 
1,0,0,0
 
1,1,0,0
 
0,0,1,0
 
0,1,1,0
 
1,0,1,0
 
1,1,1,0
 
0,0,0,1
 
0,1,0,1
 
1,0,0,1
 
1,1,0,1
 
0,0,1,1
 
0,1,1,1
 
1,0,1,1
 
1,1,1,1
Data signaling rate
 
V.27 ter fall back mode
 
V.27 ter 
 
V.29
 
V.27 ter and V.29
 
Not used
 
Reserved
 
Not used
 
V.27 ter and V.29 and V.33
 
Not used
 
Reserved
 
Not used
 
V.27 ter and V.29 and V.33 and V.17
 
Not used
 
Reserved
 
Not used
 
Reserved
Data signaling rate
 
2400 bit/s, V.27 ter
 
4800 bit/s, V.27 ter
 
9600 bit/s, V.29
 
7200 bit/s, V.29
 
14400 bit/s, V.33
 
12000 bit/s, V.33
 
Reserved
 
Reserved
 
14400 bit/s, V.17
 
12000 bit/s, V.17
 
9600 bit/s, V.17
 
7200 bit/s, V.17
 
Reserved
 
Reserved
 
Reserved
 
Reserved
15
R8
×7.7 lines/mm and/or 200×200 pels/25.4mm
R8
×7.7 lines/mm and/or 200×200 pels/25.4mm
16
Two-dimensional coding capability
Two-dimensional coding capability
17, 18
 
(0, 0)
 
 
(0, 1)
 
 
 
 
 
 
(1, 0)
 
 
 
 
(1, 1)
Recording width capabilities
 
1728 picture elements along scan line length of 
 
    215 mm ± 1%
 
1728 picture elements along scan line length of 
 
    215 mm ± 1%
 
2048 picture elements along scan line length of 
 
    255 mm ± 1%
 
2432 picture elements along scan line length of 
 
    303 mm ± 1%
 
1728 picture elements along scan line length of 
 
    215 mm ± 1%
 
2048 picture elements along scan line length of 
 
    255 mm ± 1%
 
Invalid
Recording width
 
1728 picture elements along scan line length of 
 
    215 mm ± 1%
 
2432 picture elements along scan line length of 
 
    303 mm ± 1%
 
 
 
 
 
2048 picture elements along scan line length of 
 
    255 mm ± 1%
 
 
 
Invalid
19, 20
 
(0, 0)
 
(0, 1)
 
(1, 0)
 
(1, 1)
Maximum recording length capability
 
A4 (297 mm)
 
Unlimited
 
A4 (297 mm) and B4 (364 mm)
 
Invalid
Maximum recording length
 
A4 (297 mm)
 
Unlimited
 
B4 (364 mm)
 
Invalid
Bit No.
DIS/DTC
DCS
32
KX-FLB813RU
Note 1 - Standard facsimile units conforming to T.2 must have the following capability: Index of cooperation (IOC)=264.
Note 2 - Standard facsimile units conforming to T.3 must have the following capability: Index of cooperation (IOC)=264.
Note 3 - Standard facsimile units conforming to T.4 must have the following capability: Paper length=297 mm.
21, 22, 23
 
(0, 0, 0)
 
(0, 0, 1)
 
(0, 1, 0)
 
(1, 0, 0)
 
(0, 1, 1)
 
(1, 1, 0)
 
(1, 0, 1)
 
(1, 1, 1)
Minimum scan line time capability of the receiver
 
20 ms at 3.85 l/mm: T
7.7
 = T
3.85
 
40 ms at 3.85 l/mm: T
7.7
 = T
3.85
 
10 ms at 3.85 l/mm: T
7.7
 = T
3.85
 
5 ms at 3.85 l/mm: T
7.7
 = T
3.85
 
10 ms at 3.85 l/mm: T
7.7
 = 1/2 T
3.85
 
20 ms at 3.85 l/mm: T
7.7
 = 1/2 T
3.85
 
40 ms at 3.85 l/mm: T
7.7
 = 1/2 T
3.85
 
0 ms at 3.85 l/mm: T
7.7
 = T
3.85
Minimum scan line time
 
20 ms
 
40 ms
 
10 ms
 
5 ms
 
 
 
 
 
 0 ms
24
Extend field
Extend field
25
2400 bit/s handshaking
2400 bit/s handshaking
26
Uncompressed mode
Uncompressed mode
27
Error correction mode
Error correction mode
28
Set to “0”.
Frame size 0 = 256 octets     1 = 64 octets
29
Error limiting mode
Error limiting mode
30
Reserved for G4 capability on PSTN
Reserved for G4 capability on PSTN
31
T.6 coding capability
T.6 coding enabled
32
Extend field
Extend field
33
 
(0)
 
(1)
Validity of bits 17, 18
 
Bits 17, 18 are valid
 
Bits 17, 18 are invalid
Recording width
 
Recording width indicated by bits 17, 18
 
Recording width indicated by this field bit information
34
Recording width capability 1216 picture elements along
scan line length of 151 ± mm 1%
Middle 1216 elements of 1728 picture elements
35
Recording width capability 864 picture elements along scan
line length of 107 ± mm 1%
Middle 864 elements of 1728 picture elements
36
Recording width capability 1728 picture elements along
scan line length of 151 ± mm 1%
Invalid
37
Recording width capability 1728 picture elements along
scan line length of 107 ± mm 1%
Invalid
38
Reserved for future recording width capability.
39
Reserved for future recording width capability.
40
Extend field
Extend field
41
R8
×15.4 lines/mm
R8
×15.4 lines/mm
42
300
×300 pels/25.4 mm
300
×300 pels/25.4 mm
43
R16
×15.4 lines/mm and/or 400×400 pels/25.4 mm
R16
×15.4 lines/mm and/or 400×400 pels/25.4 mm
44
Inch based resolution preferred
Resolution type selection
 
“0”: neuritic based resolution
 
“1”: inch based resolution
45
Metric based resolution preferred
Don’t care
46
Minimum scan line time capability for higher resolutions
 
“0”: T
15.4
 = T
7.7
       “1”: T
15.4
 = 1/2T
7.7
Don’t care
47
Selective Polling capability
Set to “0”.
48
Extend field
Extend field
Signal
Identification Signal Format
Function
Training 1
———————
A fixed pattern is transmitted to the receiving side at a speed (2400
to 14400 bps) designated by DCS, and the receiving side optimizes
the automatic equalizer, etc., according to this signal.
Bit No.
DIS/DTC
DCS