DOWNLOAD Panasonic KX-FL423RU Service Manual ↓ Size: 10.1 MB | Pages: 127 in PDF or view online for FREE

Model
KX-FL423RU
Pages
127
Size
10.1 MB
Type
PDF
Document
Service Manual
Brand
Device
Fax / COMPACT LASER FAX
File
kx-fl423ru.pdf
Date

Panasonic KX-FL423RU Service Manual ▷ View online

29
KX-FL423RU-B / KX-FL423RU-W 
b. Redundancy Compression Process Coding Mode
This unit uses one-dimensional MH format.
TCF
 
(Training Check)
———————
Sends 0 continuously for 1.5 seconds at the same speed as the
training signal.
CFR 
 
(Confirmation to Receive)
X0100001
Notifies the sending side that TCF has been properly received. If
TCF is not properly received, FTT (Failure To Train) X0100010 is
relayed to the sender. The sender then reduces the transmission
speed by one stage and initiates training once again.
Training 2
———————
Used for reconfirming the receiving side like training 1.
Image Signal
Refer to the next page.
———————
RTC
 
(Return to Control)
———————
Sends 12 bits (0...01 
× 6 times) to the receiver at the same speed as
the image signal and notifies completion of transmission of the first
sheet.
EOP
 
(End of Procedure)
X1110100
End of one communication
MCF
 
(Message Confirmation)
X0110001
End of 1 page reception
DCN
 
(Disconnect)
X1011111
Phase E starts.
MPS
 
(Multi-Page Signal)
X1110010
Completion of transmission of 1 page. If there are still more docu-
ments to be sent, they are output instead of EOP. After MCF recep-
tion, the sender transmits an image signal of the second sheet.
PRI-EOP
 
(Procedural Interrupt-EOP)
X1111100
If there is an operator call from the sender, it is output after RTC.
PIP
 
(Procedural Interrupt Positive)
X0110101
This is output when an operator call is received.
Signal
Identification Signal Format
Function
30
KX-FL423RU-B / KX-FL423RU-W 
6.6.
NCU Section
6.6.1.
General
NCU is the with the telephone line. It is composed of Bell detection circuit, Pulse dial circuit, Line amplifier and sidetone circuits. The
following is a brief explanation of each circuit.
6.6.2.
Line Relay (RLY401)
1. Circuit Operation
Normally, this relay switches to the external telephone side (break) and switches to the open side (make) while OFF-HOOK.
{ IC101 (V6) High Level
→CN300 (9) High Level} →CN405 (9) High Level→Q406 ON→RLY401 (ON)→(make)
6.6.3.
Bell Detection Circuit
1. Circuit Operation
The signal waveform for each point is indicated below. The signal (low level section) input to pin V4 of SOC IC101 on the dig-
ital board is illustrated.
6.6.4.
Pulse Dial Circuit and ON/OFF Hook Circuit
 IC101 (V6) High Level(make)
→Q406 ON(make)→RL401 ON(make)→TEL line
 IC101 (V6) Low Level(break)
→Q406 OFF(break)→RL401 OFF(break)→TEL line
31
KX-FL423RU-B / KX-FL423RU-W 
6.6.5.
Line Amplifier and Side Tone Circuit
1. Circuit Operation
The reception signal output from the line transformer T401 is input to pin (2) of IC401 via C408, R409 and then the signal is
amplified at pin (1) of IC401 and sent to the reception system.
The transmission signal is output from IC107(7) and transmitted to T401 via C413 and R414. If the side tone circuit is not
applied, the transmission signal will return to the reception amplifier via C408 and R409.When the side tone circuit is active,
the signal output from IC107 pin (7) passes through R413, C410, C409,and R410 and goes into the amplifier IC401 pin (3).
This circuit is used to cancel the transmission return signal.
32
KX-FL423RU-B / KX-FL423RU-W 
6.7.
CIS Control Section
The scanning block of this device consists of a control circuit and a contact image sensor made up of a celfoc lens array, an LED, a
light guide, and photoelectric conversion elements.
When an original document is inserted and the start button pressed, pin E1 of IC101 goes to a high level and the transistor Q215
turns on. This applies voltage to the LED to light it. The contact image sensor is driven by each of the FTG-F1 signals output from
IC101, and the original image illuminated by the LED undergoes photoelectric conversion to output an analog image signal (SIG).
The analog image signal is input to the IC101 on AIN1 (pin A3) and converted into 8-bit data by the A/D converter inside IC101.
Then this signal undergoes digital processing in order to obtain a high-quality image.
Page of 127