33
KX-FC968RU-T
3. Facsimile Call Time Series
As shown in the following diagram, the facsimile call time series is divided into five phases.
Phase A: Call setting 
Call setting can be manual/automatic. 
Phase B: Pre-message procedure 
Phase B is a pre-processing procedure and sequence for confirming the status of the terminal, transmission route, etc., and for
terminal control. It implements terminal preparation status, determines and displays terminal constants, confirms
synchronization status, etc. and prepares for transmission of facsimile messages. 
Phase C: Message transmission 
Phase C is the procedure for the transmitting facsimile messages.
Phase D: Post message procedure 
Phase D is the procedure for confirming that the message is completed and received. For continuous transmission, phase B or
phase C is repeated for transmission. 
Phase E: Call retrieval 
Phase E is the procedure for call retrieval, that is for circuit disconnection.
4. Concerning Transmission Time
Transmission Time  = Control Time + Image Transmission Time + Hold Time
Transmission time consists of the following.
Control time:
This is time at the start of transmission when the functions at the sending and receiving sides are confirmed, the transmission
mode is established, and transmission and reception are synchronized.
Image transmission time:
This is the time required for the transmission of document contents (image data). In general, this time is recorded in the catalog,
etc.
Hold time:
This is the time required after the document contents have been sent to confirm that the document was actually sent, and to
check for telephone reservations and/or the existence of continuous transmission.
5. Facsimile Standards
Item
Telephone Network Facsimile
G3 Machine
Connection Control Mode
Telephone Network Signal Mode
Terminal Control Mode
T. 30 Binary
Facsimile Signal Format
Digital
Modulation Mode
PSK (V. 27 ter) or QAM (V. 29)
Transmission Speed
300 bps (Control Signal)
2400, 4800, 7200, 9600 bps (FAX Signal)
Redundancy Compression
Process
(Coding Mode)
1 dimension: MH Mode
2 dimension: MR Mode (K=2.4)
Resolution
Main Scan: 8 pel/mm
Sub Scan: 3.85, 7.7l/mm
Line Synchronization Signal
EOL Signal
1 Line Transmission Time
[ms/line]
Depends on the degree of data reduction.
Minimum Value: 10, 20
Can be recognized in 40ms.
34
KX-FC968RU-T
6. Explanation of Communication and Compression Technology
a. G3 Communication Signals (T. 30 Binary Process)
For G3 Facsimile communication, this is the procedure for exchanging control signals between the sending and receiving
machines both before and after transmission of image signals.
Control signals at 300 bps FSK are: 1850 Hz...0, 1650Hz...1. 
An example of a binary process in G3 communication is shown below.
Explanation of Signals 
Control signals are comprised mainly of 8-bit identification signals and the data signals added to them. Data signals are added
to DIS and DCS signals.
Signal.....DIS (Digital Identification Signal) 
Identification Signal Format.....00000001
Function:
Notifies the capacity of the receiving unit. The added data signals are as follows.
Signal.....DCS (Digital Command Signal) 
Identification Signal Format.....X1000001
Example (Some models do not support the following items.):
Bit No.
DIS/DTC
DCS
1
Transmitter --- T.2 operation
2
Receiver --- T.2 operation
Receiver --- T.2 operation
3
T.2 IOC = 176
T.2 IOC = 176
4
Transmitter --- T.3 operation
5
Receiver --- T.3 operation
Receiver --- T.3 operation
6
Reserved for future T.3 operation features
7
Reserved for future T.3 operation features.
8
Reserved for future T.3 operation features.
9
Transmitter --- T.4 operation
10
Receiver --- T.4 operation
Receiver --- T.4 operation
35
KX-FC968RU-T
11,12,13,14
0,0,0,0
0,1,0,0
1,0,0,0
1,1,0,0
0,0,1,0
0,1,1,0
1,0,1,0
1,1,1,0
0,0,0,1
0,1,0,1
1,0,0,1
1,1,0,1
0,0,1,1
0,1,1,1
1,0,1,1
1,1,1,1
Data signaling rate
V.27 ter fall back mode
V.27 ter 
V.29
V.27 ter and V.29
Not used
Reserved
Not used
V.27 ter and V.29 and V.33
Not used
Reserved
Not used
V.27 ter and V.29 and V.33 and V.17
Not used
Reserved
Not used
Reserved
Data signaling rate
2400 bit/s, V.27 ter
4800 bit/s, V.27 ter
9600 bit/s, V.29
7200 bit/s, V.29
14400 bit/s, V.33
12000 bit/s, V.33
Reserved
Reserved
14400 bit/s, V.17
12000 bit/s, V.17
9600 bit/s, V.17
7200 bit/s, V.17
Reserved
Reserved
Reserved
Reserved
15
R8
×7.7 lines/mm and/or 200×200 pels/25.4mm
R8
×7.7 lines/mm and/or 200×200 pels/25.4mm
16
Two-dimensional coding capability
Two-dimensional coding capability
17, 18
(0, 0)
(0, 1)
(1, 0)
(1, 1)
Recording width capabilities
1728 picture elements along scan line length of 
    215 mm ± 1%
1728 picture elements along scan line length of 
    215 mm ± 1%
2048 picture elements along scan line length of 
    255 mm ± 1%
2432 picture elements along scan line length of 
    303 mm ± 1%
1728 picture elements along scan line length of 
    215 mm ± 1%
2048 picture elements along scan line length of 
    255 mm ± 1%
Invalid
Recording width
1728 picture elements along scan line length of 
    215 mm ± 1%
2432 picture elements along scan line length of 
    303 mm ± 1%
2048 picture elements along scan line length of 
    255 mm ± 1%
Invalid
19, 20
(0, 0)
(0, 1)
(1, 0)
(1, 1)
Maximum recording length capability
A4 (297 mm)
Unlimited
A4 (297 mm) and B4 (364 mm)
Invalid
Maximum recording length
A4 (297 mm)
Unlimited
B4 (364 mm)
Invalid
21, 22, 23
(0, 0, 0)
(0, 0, 1)
(0, 1, 0)
(1, 0, 0)
(0, 1, 1)
(1, 1, 0)
(1, 0, 1)
(1, 1, 1)
Minimum scan line time capability of the receiver
20 ms at 3.85 l/mm: T
7.7
 = T
3.85
40 ms at 3.85 l/mm: T
7.7
 = T
3.85
10 ms at 3.85 l/mm: T
7.7
 = T
3.85
  5 ms at 3.85 l/mm: T
7.7
 = T
3.85
10 ms at 3.85 l/mm: T
7.7
 = 1/2 T
3.85
20 ms at 3.85 l/mm: T
7.7
 = 1/2 T
3.85
40 ms at 3.85 l/mm: T
7.7
 = 1/2 T
3.85
  0 ms at 3.85 l/mm: T
7.7
 = T
3.85
Minimum scan line time
20 ms
40 ms
10 ms
  5 ms
  0 ms
24
Extend field
Extend field
25
2400 bit/s handshaking
2400 bit/s handshaking
26
Uncompressed mode
Uncompressed mode
27
Error correction mode
Error correction mode
28
Reserved for G4 capability on PSTN
Frame size 0 = 256 octets     1 = 64 octets
29
T.6 coding capability
Error limiting mode
30
Reserved for G4 capability on PSTN
Reserved for G4 capability on PSTN
31
T.6 coding capability
T.6 coding enabled
32
Extend field
Extend field
33
(0)
(1)
Validity of bits 17, 18
Bits 17, 18 are valid
Bits 17, 18 are invalid
Recording width
Recording width indicated by bits 17, 18
Recording width indicated by this field bit information
34
Recording width capability 1216 picture elements along
scan line length of 151 ± mm 1%
Middle 1216 elements of 1728 picture elements
35
Recording width capability 864 picture elements along scan
line length of 107 ± mm 1%
Middle 864 elements of 1728 picture elements
36
Recording width capability 1728 picture elements along
scan line length of 151 ± mm 1%
Invalid
37
Recording width capability 1728 picture elements along
scan line length of 107 ± mm 1%
Invalid
38
Reserved for future recording width capability.
39
Reserved for future recording width capability.
Bit No.
DIS/DTC
DCS
36
KX-FC968RU-T
Note 1 - Standard facsimile units conforming to T.2 must have the following capability: Index of cooperation (IOC)=264.
Note 2 - Standard facsimile units conforming to T.3 must have the following capability: Index of cooperation (IOC)=264.
Note 3 - Standard facsimile units conforming to T.4 must have the following capability: Paper length=297 mm.
40
Extend field
Extend field
41
R8
×15.4 lines/mm
R8
×15.4 lines/mm
42
300
×300 pels/25.4 mm
300
×300 pels/25.4 mm
43
R16
×15.4 lines/mm and/or 400×400 pels/25.4 mm
R16
×15.4 lines/mm and/or 400×400 pels/25.4 mm
44
Inch based resolution preferred
Resolution type selection
“0”: neritic based resolution
“1”: inch based resolution
45
Metric based resolution preferred
Don’t care
46
Minimum scan line time capability for higher resolutions
“0”: T
15.4
 = T
7.7
       “1”: T
15.4
 = 1/2T
7.7
Don’t care
47
Selective Polling capability
Set to “0”.
48
Extend field
Extend field
Signal
Identification Signal Format
Function
Training 1
———————
A fixed pattern is transmitted to the receiving side at a speed (2400 to 9600 bps)
designated by DCS, and the receiving side optimizes the automatic equalizer,
etc., according to this signal.
TCF
(Training Check)
———————
Sends 0 continuously for 1.5 seconds at the same speed as the training signal.
CFR 
(Confirmation to Receive)
X0100001
Notifies the sending side that TCF has been properly received. If TCF is not
properly received, FTT (Failure To Train) X0100010 is relayed to the sender.
The sender then reduces the transmission speed by one stage and initiates
training once again.
Training 2
———————
Used for reconfirming the receiving side like training 1.
Image Signal
Refer to the next page.
———————
RTC
(Return to Control)
———————
Sends 12 bits (0...01 
× 6 times) to the receiver at the same speed as the image
signal and notifies completion of transmission of the first sheet.
EOP
(End of Procedure)
X1110100
End of one communication
MCF
(Message Confirmation)
X0110001
End of 1 page reception
DCN
(Disconnect)
X1011111
Phase E starts.
MPS
(Multi-Page Signal)
X1110010
Completion of transmission of 1 page. If there are still more documents to be
sent, they are output instead of EOP. After MCF reception, the sender transmits
an image signal of the second sheet.
PRI-EOP
(Procedural Interrupt-EOP)
X1111100
If there is an operator call from the sender, it is output after RTC.
PIP
(Procedural Interrupt Positive)
X0110101
This is output when an operator call is received.
Bit No.
DIS/DTC
DCS
Page of 127