Panasonic DMC-TZ10EB / DMC-TZ10EE / DMC-TZ10EF / DMC-TZ10EP / DMC-TZ10GC / DMC-TZ10GN / DMC-TZ10SG / DMC-ZS7P / DMC-ZS7PC / DMC-ZS7PU / DMC-ZS7GD / DMC-ZS7GH / DMC-ZS7GK / DMC-ZS7GT Service Manual ▷ View online

17
5 Location of Controls and Components
18
19
6 Service Mode
6.1.
Error Code Memory Function
1. General description
This unit is equipped with history of error code memory function, and can be memorized 16 error codes in sequence from the                   
latest. When the error is occurred more than 16, the oldest error is overwritten in sequence.
The error code is not memorized when the power supply is shut down forcibly (i.e.,when the unit is powered on by the battery,
the battery is pulled out) The error code is memorized to FLASH ROM when the unit has just before powered off.
2. How to display
The error code can be displayed by ordering the following procedure:
• Preparation:
1. Attach the Battery or AC Adaptor with a DC coupler to the unit.
2. Set the mode dial to the PROGRAM AE mode.
Note: 
*Since this unit has built-in memory, it can be performed without inserting SD memory card.
• Step 1. The temporary cancellation of "INITIAL SETTINGS":
Set the REC/PLAYBACK selector switch to "REC (Camera mark)".
While keep pressing "UP of Cursor button" and DISPLAY button simultaneously, turn the Power on.
• Step 2. Execute the error code display mode:
Press the "LEFT of Cursor button", MENU/SET button and DISPLAY button simultaneously.
The display is changed as shown below when the above buttons are pressed simultaneously.
Normal display 
→ Error code display → Operation history display → Normal display → .....
20
3. Error Code List
The error code consists of 8 bits data and it shows the following information.
Attribute
Main item
Sub item
Error code
Contents (Upper)
Error Indication
High 4bits Low 4 bits
Check point (Lower)
Detecting
device
Part/Circuit
LENS
Lens drive OIS
18*0
1000
PSD (X) error. Hall element (X axis) position detect
error in OIS unit.
OIS X
LENSu NG
OIS Unit
2000
PSD (Y) error. Hall element (Y axis) position detect
error in OIS unit.
OIS Y
OIS Unit
3000
GYRO (X) error. Gyro (IC7301) detect error on Main
P.C.B.
GYRO X
GYRO NG
IC7301 (Gyro element) or IC6001 (VENUS HD2)
4000
GYRO (Y) error. Gyro (IC9701) detect error on Main
P.C.B.
GYRO Y
IC9701 (Gyro element) or IC6001 (VENUS HD2)
5000
MREF error (Reference voltage error).
OIS REF
LENSSd/DSP 
NG
IC9101 (LENS drive) or IC6001 (VENUS HD2)
6000
Drive voltage (X) error.
OISX REF
LENSu/LENS 
FPC
LENS Unit, LENS flex breaks, IC6001(VENUS HD2)
AD value error, etc.
7000
Drive voltage (Y) error.
OISY REF
LENS Unit, LENS flex breaks, IC6001(VENUS HD2)
AD value error, etc.
Zoom
(C.B.)
0?10
Collapsible barrel Low detect error
ZOOM L
ZOOMm/
LENSu
(Collapsible barrel encoder always detects Low.)
Mechanical lock, FP9005-(26) signal line or IC6001
(VENUS HD2)
0?20
Collapsible barrel High detect error
ZOOM H
(Collapsible barrel encoder always detects High.)
Mechanical lock, FP9005-(26) signal line or IC6001
(VENUS HD2)
0?30
Zoom motor sensor error.
ZOOM ENC
Mechanical lock, FP9005-(37), (40) signal line or
IC6001 (VENUS HD2)
0?40
Zoom motor sensor error. (During monitor mode.)
Mechanical lock, FP9005-(37), (40) signal line or
IC6001 (VENUS HD2)
0?50
Zoom motor sensor error. (During monitor mode with
slow speed.)
Mechanical lock, FP9005-(37), (40) signal line or
IC6001 (VENUS HD2)
Focus
0?01
HP High detect error
(Focus encoder always detects High, and not
becomes Low)
FOCUS L
LENS FPC/
DSP
Mechanical lock, FP9005-(26) signal line or IC6001
(VENUS HD2)
0?02
HP Low detect error
(Focus encoder always detects Low, and not
becomes High)
FOCUS H
Mechanical lock, FP9005-(26) signal line or IC6001
(VENUS HD2)
Lens
18*1
0000
Power ON time out error.
LENS DRV
LENSu
Lens drive system
18*2
0000
Power OFF time out error.
Lens drive system
Adj.History OIS
19*0
2000
OIS adj. Yaw direction amplitude error (small)
OIS ADJ
OIS ADJ
3000
OIS adj. Pitch direction amplitude error (small)
4000
OIS adj. Yaw direction amplitude error (large)
5000
OIS adj. Pitch direction amplitude error (large)
6000
OIS adj. MREF error
7000
OIS adj. time out error
8000
OIS adj. Yaw direction off set error
9000
OIS adj. Pitch direction off set error
A000
OIS adj. Yaw direction gain error
B000
OIS adj. Pitch direction gain error