DOWNLOAD Panasonic DMC-FZ8P / DMC-FZ8PC / DMC-FZ8PL / DMC-FZ8EB / DMC-FZ8EE / DMC-FZ8EF / DMC-FZ8EG / DMC-FZ8EGM / DMC-FZ8GC / DMC-FZ8GD / DMC-FZ8GK / DMC-FZ8GN / DMC-FZ8GT / DMC-FZ8SG Service Manual ↓ Size: 3.17 MB | Pages: 50 in PDF or view online for FREE

Model
DMC-FZ8P DMC-FZ8PC DMC-FZ8PL DMC-FZ8EB DMC-FZ8EE DMC-FZ8EF DMC-FZ8EG DMC-FZ8EGM DMC-FZ8GC DMC-FZ8GD DMC-FZ8GK DMC-FZ8GN DMC-FZ8GT DMC-FZ8SG
Pages
50
Size
3.17 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / DIGITAL CAMERA
File
dmc-fz8p-dmc-fz8pc-dmc-fz8pl-dmc-fz8eb-dmc-fz8ee-d.pdf
Date

Panasonic DMC-FZ8P / DMC-FZ8PC / DMC-FZ8PL / DMC-FZ8EB / DMC-FZ8EE / DMC-FZ8EF / DMC-FZ8EG / DMC-FZ8EGM / DMC-FZ8GC / DMC-FZ8GD / DMC-FZ8GK / DMC-FZ8GN / DMC-FZ8GT / DMC-FZ8SG Service Manual ▷ View online

17
About "*" indication in the above table:
The third digit from the left is different as follows.
- In case of 0 (example: 18001000)
When the third digit from the left shows "0", this error occurred under the condition of INITIAL SETTINGS has been 
completed.
It means that this error is occurred basically at user side.
- In case of 8 (example: 18801000)
When the third digit from the left shows "8", this error occurred under the condition of INITIAL SETTINGS has been
released. 
(Example; Factory assembling-line before unit shipment, Service mode etc.)
It means that this error is occurred at service side.
• 6. How to returned to Normal Display:
Turn the power off and on, to exit from Error code display mode.
NOTE:
The error code can not be initialized.
SOFT
CPU
Reset
30*0
0001
|
0007
NMI reset
Non Mask-able Interrupt
(30000001-30000007 are caused by factors)
Card
Card
31*0
0001
Card logic error
SD memory card data line or IC6001 (VENUS 3)
0002
Card physical error
SD memory card data line or IC6001 (VENUS 3)
0004
Write error
SD memory card data line or IC6001 (VENUS 3)
39*0
0005
Format error
CPU, 
ASIC hard
Stop
38*0
0001
Camera task finish process time out.
Communication between Lens system and IC6001 (VENUS 3)
0002
Camera task invalid code error.
IC6001 (VENUS 3)
0100
File time out error in recording motion image
IC6001 (VENUS 3)
0200
File data send error in recording motion image
IC6001 (VENUS 3)
0300
Single or burst recording brake time out.
Operation
Power on
3B*0
0000
FLASHROM processing early period of camera during movement.
Zoom
Zoom
3C*0
0000
Inperfect zoom lens processing.
Zoom lens
35*0
0001
|
0007
Software error.
(0-7bit : command, 8-15bit : status)
35*1
0000
Though record preprocessing is necessary, it is not called.
35*2
0000
Though record preprocessing is necessary, it is not completed.
Attribute
Main item
Sub item
Error code
Contents (Upper)
High 4 bits Low 4 bits
Check point (Lower)
18
6.2.
Confirmation of Firmware Version
The Firmware version can be confirmed by ordering the following steps:.
• Step 1. The temporary cancellation of initial setting:
Set the mode dial to “[ P ]”. 
Insert the SD memory card which has a few photo data.
While keep pressing [ Optical Image Stabilizer ] and “[ UP ] of Cross key” simultaneously, then turn the power on.
• Step 2. Confirm the version:
Set the mode dial to “[ Playback ]” and then press [ DISPLAY ] to switch to LCD with indication. (Fig. A)
Press [ Optical Image Stabilizer ] and “[ DOWN ] of Cross key” simultaneously. (No need to keep pressing.)
(The version information is displayed on the LCD with light blue colour letters.) (Fig. B) 
CAUTION:
The version information does not display if the LCD has switched to LCD with indication already.
In this case, press [ DISPLAY ] to switch to LCD with indication.
<Point>
• The firmware version and EEPROM version can be confirmed with the information (1).
• The information (2), (3) are just reference.
19
7 Service Fixture & Tools
7.1.
Service Fixture and Tools
The following Service Fixture and tools are used for checking and servicing this unit.
20
7.2.
When Replacing the Main PCB
After replacing the MAIN PCB, be sure to achieve adjustment.
The adjustment instruction is available at “software download” on the “Support Information from NWBG/VDBG-PAVC” web-site in
“TSN system”, together with Maintenance software.
7.3.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
Table S1 Extension Cable List
No.
Parts No.
Connection
Form
1
RFKZ0361
FP9001 (MAIN) - CCD UNIT
28PIN 0.5 FFC
2
RFKZ0389
FP9002 (MAIN) - TOP OPERATION UNIT
11PIN 0.5 FFC
3
RFKZ0363
FP9003 (MAIN) - LCD UNIT
19PIN 0.5 FFC
4
VFK1443
FP9004 (MAIN) - EVF UNIT
18PIN 0.5 FFC
5
VFK1953
FP9005 (MAIN) - LENS FPC UNIT
40PIN 0.5 FFC
6
VFK1974
FP9006 (MAIN) - LCD UNIT
4PIN 0.5 FFC
7
VFK1576DSC04
P9001 (MAIN) - SPEAKER
2PIN CABLE
8
RFKZ0359
P9003 (MAIN) - FLASH UNIT
2PIN CABLE
9
VFK1576DC202
P9004 (MAIN) - FLASH UNIT
2PIN CABLE
10
VFK1576DC202
P9005 (MAIN) - FLASH UNIT
2PIN CABLE
11
RFKZ0360
P9006 (MAIN) - P9301 (AF LED/MIC)
5PIN CABLE
12
VFK1480
FP9007 (MAIN) - EVF UNIT
6PIN 0.5 FFC
Page of 50
Display