DOWNLOAD Panasonic DMC-FX500P / DMC-FX500PC / DMC-FX500PL / DMC-FX500E / DMC-FX500EB / DMC-FX500EE / DMC-FX500EF / DMC-FX500EG / DMC-FX500SG / DMC-FX520GC / DMC-FX520GD / DMC-FX520GK / DMC-FX520GN / DMC-FX520GT / DMC-FX520GJ / DMC-FX500EES / DMC-FX500EEK Service Manual ↓ Size: 2.84 MB | Pages: 54 in PDF or view online for FREE

Model
DMC-FX500P DMC-FX500PC DMC-FX500PL DMC-FX500E DMC-FX500EB DMC-FX500EE DMC-FX500EF DMC-FX500EG DMC-FX500SG DMC-FX520GC DMC-FX520GD DMC-FX520GK DMC-FX520GN DMC-FX520GT DMC-FX520GJ DMC-FX500EES DMC-FX500EEK
Pages
54
Size
2.84 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / DIGITAL CAMERA
File
dmc-fx500p-dmc-fx500pc-dmc-fx500pl-dmc-fx500e-dmc-.pdf
Date

Panasonic DMC-FX500P / DMC-FX500PC / DMC-FX500PL / DMC-FX500E / DMC-FX500EB / DMC-FX500EE / DMC-FX500EF / DMC-FX500EG / DMC-FX500SG / DMC-FX520GC / DMC-FX520GD / DMC-FX520GK / DMC-FX520GN / DMC-FX520GT / DMC-FX520GJ / DMC-FX500EES / DMC-FX500EEK Service Manual ▷ View online

17
About "*" indication in the above table:
The third digit from the left is different as follows.
- In case of 0 (example: 18001000)
When the third digit from the left shows "0", this error occurred under the condition of INITIAL SETTINGS has been 
completed.
It means that this error is occurred basically at user side.
- In case of 8 (example: 18801000)
When the third digit from the left shows "8", this error occurred under the condition of INITIAL SETTINGS has been
released. 
(Example; Factory assembling-line before unit shipment, Service mode etc.)
It means that this error is occurred at service side.
• 6. How to returned to Normal Display:
Turn the power off and on, to exit from Error code display mode.
NOTE:
The error code can not be initialized.
HARD
VENUS A/D
Flash
28*0
0000
Flash charging error.
IC6001-(AC17) signal line or Flash charging circuit
FLASH ROM
(EEPROM 
Area)
FLASH ROM
(EEPROM 
Area)
2B*0
0001
EEPROM read error
IC6002 (FLASH ROM)
0002
EEPROM write error
IC6002 (FLASH ROM)
SYSTEM
RTC
2C*0
0001
SYSTEM IC initialize failure error
Communication between IC6001 (VENUS 4) and IC9101 (SYSTEM)
SOFT
CPU
Reset
30*0
0001
|
0007
NMI reset
Non Mask-able Interrupt
(30000001-30000007 are caused by factors)
Card
Card
31*0
0001
Card logic error
SD memory card data line or IC6001 (VENUS 4)
0002
Card physical error
SD memory card data line or IC6001 (VENUS 4)
0004
Write error
SD memory card data line or IC6001 (VENUS 4)
39*0
0005
Format error
CPU, 
ASIC hard
Stop
38*0
0001
Camera task finish process time out.
Communication between Lens system and IC6001 (VENUS 4)
0002
Camera task invalid code error.
IC6001 (VENUS 4)
0100
File time out error in recording motion image
IC6001 (VENUS 4)
0200
File data send error in recording motion image
IC6001 (VENUS 4)
0300
Single or burst recording brake time out.
Operation
Power on
3B*0
0000
FLASHROM processing early period of camera during movement.
Zoom
Zoom
3C*0
0000
Inperfect zoom lens processing
Zoom lens
35*0
0000
|
FFFF
Software error
(0-7bit : command, 8-15bit : status)
35*1
0000
Though record preprocessing is necessary, it is not called.
35*2
0000
Though record preprocessing is necessary, it is not completed.
Attribute
Main item
Sub item
Error code
Contents (Upper)
High 4 bits Low 4 bits
Check point (Lower)
18
7 Service Fixture & Tools
7.1.
Service Fixture and Tools
The following Service Fixture and tools are used for checking and servicing this unit.
19
7.2.
When Replacing the Main PCB
After replacing the MAIN PCB, be sure to achieve adjustment.
The adjustment instruction is available at “software download” on the “Support Information from NWBG/VDBG-PAVC” web-site in
“TSN system”, together with Maintenance software.
7.3.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
Table S1 Extension Cable List
CAUTION-1. (When servicing FLASH TOP PCB)
1. Be sure to discharge the capacitor on FLASH TOP PCB.
Refer to “HOW TO DISCHARGE THE CAPACITOR ON FLASH TOP PCB”.
The capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on FLASH TOP PCB.
3. DO NOT allow other parts to touch the high voltage circuit on FLASH TOP PCB.
No.
Parts No.
Connection
Form
1
RFKZ0416
FP9001 (MAIN) - CCD UNIT
41PIN 0.3 FFC
2
RFKZ0477
FP9002 (MAIN) - LENS UNIT
45PIN 0.3 FFC
3
VFK1974
FP9006 (MAIN) - LCD UNIT
4PIN 0.5 FFC
4
VFK1480
FP9007 (MAIN) -REAR OPERATION UNIT
6PIN 0.5 FFC
5
VFK1951
FP9003 (MAIN) - LCD UNIT
39PIN 0.3 FFC
6
VFK1974
FP9004 (MAIN) - LCD UNIT
4PIN 0.5 FFC
7
RFKZ0418
PP9002 (MAIN) - PS8001 (FLASH TOP)
30PIN B to B
20
8 Disassembly and Assembly Instructions
8.1.
Disassembly Flow Chart
8.2.
PCB Location
Page of 54
Display

Click on the first or last page to see other DMC-FX500P / DMC-FX500PC / DMC-FX500PL / DMC-FX500E / DMC-FX500EB / DMC-FX500EE / DMC-FX500EF / DMC-FX500EG / DMC-FX500SG / DMC-FX520GC / DMC-FX520GD / DMC-FX520GK / DMC-FX520GN / DMC-FX520GT / DMC-FX520GJ / DMC-FX500EES / DMC-FX500EEK service manuals if exist.