DOWNLOAD Panasonic DMC-FP5P / DMC-FP5PC / DMC-FP5PR / DMC-FP5PU / DMC-FP5EB / DMC-FP5EE / DMC-FP5EG / DMC-FP5GA / DMC-FP5GC / DMC-FP5GF / DMC-FP5GK / DMC-FP5GT Service Manual ↓ Size: 3.54 MB | Pages: 55 in PDF or view online for FREE

Model
DMC-FP5P DMC-FP5PC DMC-FP5PR DMC-FP5PU DMC-FP5EB DMC-FP5EE DMC-FP5EG DMC-FP5GA DMC-FP5GC DMC-FP5GF DMC-FP5GK DMC-FP5GT
Pages
55
Size
3.54 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / DIGITAL CAMERA
File
dmc-fp5p-dmc-fp5pc-dmc-fp5pr-dmc-fp5pu-dmc-fp5eb-d.pdf
Date

Panasonic DMC-FP5P / DMC-FP5PC / DMC-FP5PR / DMC-FP5PU / DMC-FP5EB / DMC-FP5EE / DMC-FP5EG / DMC-FP5GA / DMC-FP5GC / DMC-FP5GF / DMC-FP5GK / DMC-FP5GT Service Manual ▷ View online

 ORDER NO. DSC1102014CE
B26
Digital Camera
Model No.
DMC-FP5P
DMC-FP5PC
DMC-FP5PR
DMC-FP5PU
DMC-FP5EB
DMC-FP5EE
DMC-FP5EG
DMC-FP5GA
DMC-FP5GC
DMC-FP5GF
DMC-FP5GK
DMC-FP5GT
Vol. 1
Colour
(K)...........Black Type
(S)...........Silver Type (except PR/EB/EG) 
(P)...........Pink Type (except PC/EB/EG)
(A)...........Blue Type (only P/PC/PU/GK)
(G)...........Green Type (only PU)
2
TABLE OF CONTENTS
PAGE
PAGE
1 Safety Precautions -----------------------------------------------3
1.1. General Guidelines ----------------------------------------3
1.2. Leakage Current Cold Check ---------------------------3
1.3. Leakage Current Hot Check (See Figure 1.) --------3
1.4. How to Discharge the E.Capacitor on Flash
P.C.B.----------------------------------------------------------4
2 Warning --------------------------------------------------------------5
2.1. Prevention of Electrostatic Discharge (ESD)
to Electrostatically Sensitive (ES) Devices ----------5
2.2. How to Recycle the Lithium Ion Battery (U.S.
Only)-----------------------------------------------------------5
2.3. Caution for AC Cord(For EB/GC) ----------------------6
2.4. How to Replace the Lithium Battery -------------------7
3 Service Navigation------------------------------------------------8
3.1. Introduction --------------------------------------------------8
3.2. General Description About Lead Free Solder
(PbF) ----------------------------------------------------------8
3.3. Important Notice 1:(Other than U.S.A. and
Canadian Market) ------------------------------------------8
3.4. How to Define the Model Suffix (NTSC or PAL
model)---------------------------------------------------------9
4 Specifications ---------------------------------------------------- 13
5 Location of Controls and Components------------------ 14
6 Service Mode ----------------------------------------------------- 19
6.1. Error Code Memory Function ------------------------- 19
7 Service Fixture & Tools --------------------------------------- 22
7.1. Service Fixture and Tools ------------------------------ 22
8 Disassembly and Assembly Instructions --------------- 23
8.1. Disassembly Flow Chart-------------------------------- 23
8.2. PCB Location---------------------------------------------- 23
8.3. Disassembly Procedure -------------------------------- 24
9 Measurements and Adjustments -------------------------- 32
9.1. Introduction ------------------------------------------------ 32
9.2. Before Disassembling the unit ------------------------ 32
9.3. Details of Electrical Adjustment----------------------- 34
9.4. After Adjustment------------------------------------------ 38
10 Maintenance ------------------------------------------------------ 39
10.1. Cleaning Lens and LCD Panel ----------------------- 39
3
1 Safety Precautions
1.1.
General Guidelines
1. IMPORTANT SAFETY NOTICE
There are special components used in this equipment
which are important for safety. These parts are marked by
in the Schematic Diagrams, Circuit Board Layout,
Exploded Views and Replacement Parts List. It is essen-
tial that these critical parts should be replaced with manu-
facturer’s specified parts to prevent X-RADIATION,
shock, fire, or other hazards. Do not modify the original
design without permission of manufacturer.
2. An Isolation Transformer should always be used during
the servicing of AC Adaptor whose chassis is not isolated
from the AC power line. Use a transformer of adequate
power rating as this protects the technician from acci-
dents resulting in personal injury from electrical shocks. It
will also protect AC Adaptor from being damaged by acci-
dental shorting that may occur during servicing.
3. When servicing, observe the original lead dress. If a short
circuit is found, replace all parts which have been over-
heated or damaged by the short circuit.
4. After servicing, see to it that all the protective devices
such as insulation barriers, insulation papers shields are
properly installed.
5. After servicing, make the following leakage current
checks to prevent the customer from being exposed to
shock hazards.
1.2.
Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the
two prongs on the plug.
2. Measure the resistance value, with an ohmmeter,
between the jumpered AC plug and each exposed metal-
lic cabinet part on the equipment such as screwheads,
connectors, control shafts, etc. When the exposed metal-
lic part has a return path to the chassis, the reading
should be between 1 M
Ω and 5.2 MΩ. When the exposed
metal does not have a return path to the chassis, the
reading must be infinity.
1.3.
Leakage Current Hot Check
(See Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer for this check.
2. Connect a 1.5 k
Ω, 10 W resistor, in parallel with a 0.15 μF
capacitor, between each exposed metallic part on the set
and a good earth ground, as shown in Figure 1.
3. Use an AC voltmeter, with 1 k
Ω/V or more sensitivity, to
measure the potential across the resistor.
4. Check each exposed metallic part, and measure the volt-
age at each point.
5. Reverse the AC plug in the AC outlet and repeat each of
the above measurements.
6. The potential at any point should not exceed 0.75 V RMS.
A leakage current tester (Simpson Model 229 or equiva-
lent) may be used to make the hot checks, leakage cur-
rent must not exceed 1/2 mA. In case a measurement is
outside of the limits specified, there is a possibility of a
shock hazard, and the equipment should be repaired and
rechecked before it is returned to the customer.
Figure. 1
4
1.4.
How to Discharge the E.Capacitor on Flash P.C.B.
CAUTION:
1. Be sure to discharge the E.capacitor on FLASH P.C.B..
2. Be careful of the high voltage circuit on FLASH P.C.B. when servicing.
[Discharging Procedure]
1. Refer to the disassemble procedure and remove the necessary parts/unit.
2. Install the insulation tube onto the lead part of resistor (ERG5SJ102:1k
Ω /5W).
(An equivalent type of resistor may be used.)
3. Place a resistor between both terminals of E.capacitor on the FLASH  P.C.B. for approx. 5 seconds.
4. After discharging, confirm that the E.capacitor voltage is lower than 10V using a voltmeter.
Fig. F1
Page of 55
Display

Panasonic DMC-FP5P / DMC-FP5PC / DMC-FP5PR / DMC-FP5PU / DMC-FP5EB / DMC-FP5EE / DMC-FP5EG / DMC-FP5GA / DMC-FP5GC / DMC-FP5GF / DMC-FP5GK / DMC-FP5GT Service Manual ▷ Download

  • DOWNLOAD Panasonic DMC-FP5P / DMC-FP5PC / DMC-FP5PR / DMC-FP5PU / DMC-FP5EB / DMC-FP5EE / DMC-FP5EG / DMC-FP5GA / DMC-FP5GC / DMC-FP5GF / DMC-FP5GK / DMC-FP5GT Service Manual ↓ Size: 3.54 MB | Pages: 55 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic DMC-FP5P / DMC-FP5PC / DMC-FP5PR / DMC-FP5PU / DMC-FP5EB / DMC-FP5EE / DMC-FP5EG / DMC-FP5GA / DMC-FP5GC / DMC-FP5GF / DMC-FP5GK / DMC-FP5GT in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic DMC-FP5P / DMC-FP5PC / DMC-FP5PR / DMC-FP5PU / DMC-FP5EB / DMC-FP5EE / DMC-FP5EG / DMC-FP5GA / DMC-FP5GC / DMC-FP5GF / DMC-FP5GK / DMC-FP5GT Digital Camera. Information contained in Panasonic DMC-FP5P / DMC-FP5PC / DMC-FP5PR / DMC-FP5PU / DMC-FP5EB / DMC-FP5EE / DMC-FP5EG / DMC-FP5GA / DMC-FP5GC / DMC-FP5GF / DMC-FP5GK / DMC-FP5GT Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.