Panasonic DMC-FP1P / DMC-FP1PC / DMC-FP1PR / DMC-FP1PU / DMC-FP1EB / DMC-FP1EE / DMC-FP1EF / DMC-FP1EG / DMC-FP1EP / DMC-FP1GC / DMC-FP1GD / DMC-FP1GF / DMC-FP1GH / DMC-FP1GK / DMC-FP1GN / DMC-FP1GT / DMC-FP2P / DMC-FP2PC / DMC-FP2PR / DMC-FP2PU / DMC-FP2EB / DMC-F Service Manual ▷ View online
33
9.3.
Details of Electrical Adjustment
9.3.1.
How to execute the Electrical Adjustment
It is not necessary to connect the camera to a PC to perform adjustments.
“Flag reset operation” and “Initial setting operation” are required when carrying out the alignment, follow the procedure below.
“Flag reset operation” and “Initial setting operation” are required when carrying out the alignment, follow the procedure below.
9.3.1.1.
Startup Electrical Adjustment mode
1. Release the initial settings.
2. Insert a recordable SD card.
2. Insert a recordable SD card.
(Without a SD card, the automatic adjustment can not
executed.)
executed.)
3. Procedure to set the camera into adjustment mode:
a. Set the mode into [ NORMAL PICTURE ] mode.
b. Turn the Power off.
b. Turn the Power off.
c. Turn the Power on pressing [ DISPLAY ] and [ MENU/
SET ] simultaneously.
LCD monitor displays “SERVICE MODE”.(Refer to
Fig. 3-1)
LCD monitor displays “SERVICE MODE”.(Refer to
Fig. 3-1)
9.3.1.2.
Status Adjustment Flag Setting
Reset (Not yet adjusted) the status flag condition.
1. After pressing the [ DISPLAY ] button, the LCD monitor
displays the Flag status screen (Refer to Fig.3-2)
2. Select item by pressing the Cursor buttons. (Gray cursor
is moved accordingly.)
3. Press the [ Delete ] button.
NOTE:
The selected item's flag has been changed from
“F (green)” to “0 (yellow)”.
*(Refer to Fig. 3-3)
“F (green)” to “0 (yellow)”.
*(Refer to Fig. 3-3)
*Flag conditions:
F (green)
means that the alignment has been completed and the
status flag condition is set. In this case, the flag condition
should be reset, if you try to carry out the automatic align-
ment.
0 (yellow)
means that the alignment has been not “completed” and
the status flag condition is “reset”. In this case, automatic
alignment is available.
F (green)
means that the alignment has been completed and the
status flag condition is set. In this case, the flag condition
should be reset, if you try to carry out the automatic align-
ment.
0 (yellow)
means that the alignment has been not “completed” and
the status flag condition is “reset”. In this case, automatic
alignment is available.
• In case of setting the status flag into set condition again without completion of the alignment, the status flag should be SET by
using PC, or UNDO by using ROM BACKUP function.
34
9.3.1.3.
Execute Adjustment
(In case of “OIS Adjustment”)
(In case of “OIS Adjustment”)
1. Perform step “9.3.1.1.” to “9.3.1.2.”, to reset the OIS flag
status “F” (Set) to “0” (Reset)
2. Press [ DISPLAY ] button after Flag reset.
OIS Adjustment screen is displayed on the LCD panel.
(Refer to Fig.3-4)
(Refer to Fig.3-4)
3. Press the [ Shutter ] button. The adjustment will start
automatically.
4. When the adjustment is completed successfully, adjust-
ment report menu appears with Green OK on the LCD
monitor. (Refer to Fig.3-5)
monitor. (Refer to Fig.3-5)
9.3.1.4.
Attention point during Adjustment
1. Step “9.3.1.3.” procedure shows OIS adjustment as an
example. To perform the adjustment, refer to the “9.3.2.
Adjustment Specifications” table which shows key point
for each adjustment.
Adjustment Specifications” table which shows key point
for each adjustment.
2. Do not move the light box, the camera or the chart while
adjusting. If one of these is moved accidentally, start the
adjustment again.
adjustment again.
3. Do not press any buttons/keys until the default menu
(Fig.3-6) is displayed on the LCD monitor. Otherwise,
adjustment data may not be stored properly.
adjustment data may not be stored properly.
4. If the adjustment is interrupted accidentally, the alignment
data may not be properly saved in the Flash-rom.
9.3.1.5.
Finalizing the Adjustment
1. Several adjustment flags can be reset (“F” into “0”) at the same time. In this case, when the adjustment has been completed,
the screen will change showing the adjustment for the next item until all reset items are completed.
Also, when the shutter button is pressed, the screen jump to the next adjustment item.
Also, when the shutter button is pressed, the screen jump to the next adjustment item.
2. To cancel the adjustment mode while in the process of performing the adjustment, follow this procedures.
(1) Press [ Delete ] button.
(2) Press [ RIGHT ] of Cursor button.
NOTE:
(2) Press [ RIGHT ] of Cursor button.
NOTE:
• If adjustment is cancelled with above procedure, adjustment is not completed. Make sure to adjust it later.
• Adjustment software “DIAS” is able to control the status of the adjustment flags.
• Adjustment software “DIAS” is able to control the status of the adjustment flags.
35
9.3.2.
Adjustment Specifications
The following matrix table shows the relation between the replaced part and the Necessary Adjustment.
When a part is replaced, make sure to perform the necessary adjustment(s) in the order indicated.
The table below shows all the information necessary to perform each adjustment.
When a part is replaced, make sure to perform the necessary adjustment(s) in the order indicated.
The table below shows all the information necessary to perform each adjustment.
36
9.4.
After Adjustment
9.4.1.
Initial Setting
Since the initial setting has been released to execute the built-in adjustment software, it should be set up again before shipping the
camera to the customer.
Refer to the procedure described in “3.4.2. INITIAL SETTINGS” for details.
camera to the customer.
Refer to the procedure described in “3.4.2. INITIAL SETTINGS” for details.
[ IMPORTANT ]
1. The initial setting should be done again after completing the alignment. Otherwise, the camera will not work properly.
Therefore as a warning, the camera display a warning symbol “ ! ” on the LCD monitor every time the camera is turned off.
2. Confirm that status of all adjustment flag show “F”. Even if one of the adjustment flag shows “0”, initial setting programmed is
never executed.
3. Adjustment software “DIAS” is able to control the status of the adjustment flags.
The Adjustment software “DIAS” is available at “TSN Website”, therefore, access to “TSN Website” at “Support Information
from NWBG/VDBG-AVC”.
from NWBG/VDBG-AVC”.
Click on the first or last page to see other DMC-FP1P / DMC-FP1PC / DMC-FP1PR / DMC-FP1PU / DMC-FP1EB / DMC-FP1EE / DMC-FP1EF / DMC-FP1EG / DMC-FP1EP / DMC-FP1GC / DMC-FP1GD / DMC-FP1GF / DMC-FP1GH / DMC-FP1GK / DMC-FP1GN / DMC-FP1GT / DMC-FP2P / DMC-FP2PC / DMC-FP2PR / DMC-FP2PU / DMC-FP2EB / DMC-F service manuals if exist.