10 Self Diagnostic Function
10.1. Setting of self diagnostic Function
10.1.1. Setting of self diagnostic mode
 1. To enter into self-diagnostic mode:
     ·    Press & hold VOL+ key,followed by
key for more than 2 seconds.
 2. LCD will show the following display as below:
(LCD Display)
 3. Error during Test:
     ·    Press & hold
key (> 2sec) will show blinking error code. If abnormality occurs during test, error code will be
displayed.
Example:
NOTE: Refer to error code table 11.1.
10.1.2. Test Mode Checking
 1. Operation keys and all segment display check mode:
     ·    Activate the Self Diagnosis mode before performing the following steps
     ·    Press & hold REMORT CONTROL 2 key (>2 sec) will enter this mode.
     ·    When the keys of the main set is pressed, the various corresponding key functions shall light up and display that particular
function. After all the main set keys were pressed, the LCD shows the following (Including CD LED):
 2. CD lid OPEN/CLOSE aging test mode:
     ·    Press & hold
key (>5 sec) will enter this mode.
     ·    This mode counts the number of times the CD lid open/close (MAX is 65535).
     − 
− 
− 
− :
     − 
− 
− 
− :
 3. CD unit (250Z) and CD lid reliability test mode (Combination)
     ·    Press & hold REMOTE CONTROL
→1→0key (>2 sec) will enter into this test mode.
17
SC-EN17E / SC-EN17EB / SC-EN17EG / SC-EN17GCS / SC-EN17GD
     ·    This test is the combination of CD lid operation and the inner and outer disc access operation aging test.The testing process
is as follow: CD lid OPEN
→Wait for 1sec. open state→CD lid CLOSE→TOC read → Play all tracks → Increment counter
(Repeat the whole process).
10.1.3. Exiting from self-diagnostic mode
 1. Press the POWER ON/OFF button eihter on the remote controller or main set to exit from Self-Diagnostic mode.
 2. The content of abnormalities (error code) are kept as long as the microcontroller memory is backup.
 3. If there is an error detected in RAM check at Reset, the content in the RAM shall be initialised and all the contents of
abnormalities shall be cleared.
 4. For force clearance, press “STOP” key while in self diagnostic mode.
“CLEAR” is displayed in upper row of LCD for one second followed by “T” is.
11 Description of Error Code
11.1. Error detection for CD Mechanism block
No.
Error
Error Display Problem condition
1
CD Open Switch Error
H15
Detect error during opening operation and memorised it as an error.
2
CD Close Switch (Bottom Sw)
Error
H16
Detect error during closing operation and memorised it as an error.
3
CD Rest Switch Error
F15
Under normal operation (Self-Diagnostic Mode inclusive), this error occurs
when the Rest_SW ON is not detected within the specified time (10 s) and
shall be memrised.
4
Communication between CD
LSI and Micro-P
F26
This error occurs when communication between CD LSI and Micro-P is
abnormal.
5
Power Supply Error
F76
This error occurs when PDET (Input for detecting over/under voltage of
power supply) voltage level is not in the range between 1.72V and 2.80V.
18
SC-EN17E / SC-EN17EB / SC-EN17EG / SC-EN17GCS / SC-EN17GD
12 Schematic Diagram
12.1. Schematic Diagram Notes
(All schematic diagrams may be modified at any time with the
development of new technology.)
Notes:
S351:
CD TOP DETECTION Switch in “OFF”
position.
S352:
CD BOTTOM DETECTION Switch in “OFF”
position.
S700:
REST Switch in “OFF” position.
S801:
CD switch
S802:
TUNER switch
S803:
VOL + switch.
S804:
VOL - switch
S805:
FWD- Skip Switch (
)
S806:
REV- Skip Switch (
)
S807:
CD OPEN/CLOSE Switch
S808:
POWER OFF/TAPE Switch
     ·    The voltage value and waveforms are the reference voltage
of this unit measured by DC electronic voltmeter (high
impedance) and oscilloscope on the basis of chassis.
Accordingly, there may arise some error in voltage values
and waveforms depending upon the internal impedance of
the tester or the measuring unit.
     ·    Battery Curent
Vol min.:
120mA (CD)
103mA (FM)
102mA (AM)
Vol max.:
118mA (CD)
102mA (FM)
100mA (AM)
     − 
− 
− 
− Measurement instruction
CD:
1kHz, 0dB
FM:
60dB, 30% Mod.
AM:
74dB/m, 30% Mod.
     ·    Importance safety notice:
Components
identified
by
mark
have
special
characteristics important for safety. Furthermore, special
parts which have purposes of fire-retardant (resistors), high-
quality sound (capacitors), low-noise (resistors), etc. are
used. When replacing any of components, be sure to use
only manufacturer’s specified parts shown in the parts list.
Caution!
IC, LSI and VLSI are sensitive to static electricity.
Secondary trouble can be prevented by taking care during
repair.
     ·    Cover the parts boxes made of plastics with aluminium
foil.
     ·    Put a conductive mat on the work table.
     ·    Ground the soldering iron.
     ·    Do not touch the pins of IC, LSI or VLSI with fingers
directly.
     ·    Indicated voltage values are the standard values for the unit
measured by the DC electronic circuit tester (high-
impedance) with the chassis taken as standard. Therefore,
there may exist some errors in the voltage values,
depending on theinternalimpedanceof the DC circuit tester.
     ·    No mark: All VR is set as a center position.
     ·    Signal Line
     − 
− 
− 
− 
: POSITIVE VOLTAGE LINE
     − 
− 
− 
− 
:CD PLAYBACK SIGNAL LINE
     − 
− 
− 
− 
:FM SIGNAL LINE
     − 
− 
− 
− 
:FM OSC SIGNAL LINE
     − 
− 
− 
− 
:FM/AM SIGNAL LINE
     − 
− 
− 
− 
:AM SIGNAL LINE
     − 
− 
− 
− 
:AM OSC SIGNAL LINE
     − 
− 
− 
− 
:MAIN SIGNAL LINE
Important safety notice:
Components
identified
by
mark
have
special
characteristics important for safety.
Furthermore, special parts which have purpose of fire-
retardant (resistors), high-quality sound (capacitors), low-
noise (resistors), etc. are used. When replacing any of
components, be sure to use only manufacture´s specified
parts shownintheparts list.
Caution!
     ·    IC and LSI are sensitive to static electricity.
     ·    Secondary trouble can be prevented by taking care
during repair.
     ·    Cover the parts boxes made of plastics with
aluminum foil.
     ·    Ground the soldering iron.
     ·    Put a conductive mat on the work table.
     ·    Do not touch the legs of IC or LSI with the fingers
directly.
19
SC-EN17E / SC-EN17EB / SC-EN17EG / SC-EN17GCS / SC-EN17GD
12.2. Schematic Diagram (SB-EN17)
20
SC-EN17E / SC-EN17EB / SC-EN17EG / SC-EN17GCS / SC-EN17GD
Page of 49
Display

Click on the first or last page to see other SC-EN17E / SC-EN17EB / SC-EN17EG / SC-EN17GCS / SC-EN17GD service manuals if exist.