Panasonic RX-D50EE Service Manual ▷ View online
41
8.20. Disassembly of Battery (1)
P.C.B.
• Refer to “Disassembly of Top Cabinet Assembly”.
• Refer to “Disassembly of Main P.C.B.”
• Refer to “Disassembly of Main P.C.B.”
Step 1 : Release the catch.
Caution : During assembling, ensure the cable is properly
inserted into the slot.
inserted into the slot.
Step 2 : Remove the Battery (1) P.C.B. as arrow shown.
Step 3 : Desolder 4P cable at (CN921) on the Battery (1)
P.C.B.
P.C.B.
42
8.21. Disassembly of Battery (2)
P.C.B.
• Refer to “Disassembly of Top Cabinet Assembly”.
• Refer to “Disassembly of Main P.C.B.”
• Refer to “Disassembly of Main P.C.B.”
Step 1 : Release the catch.
Step 2 : Remove the Battery (2) P.C.B. as arrow shown.
43
9 Disassembly and Assembly of Traverse Unit
9.1.
Disassembling Procedures
Step 1 : Release the guide.
Step 2 : Push the traverse slide plate (rib), ensure both grooves
are opened.
Step 2 : Push the traverse slide plate (rib), ensure both grooves
are opened.
Step 3 : Slide out the traverse unit as arrow shown.
Caution : Ensure the OPU is face upwards, avoid touching
the surface of the traverse unit.
the surface of the traverse unit.
44
9.2.
Assembling Procedure
Caution : Removal of the short pin is necessary for
replacement of new traverse unit.
replacement of new traverse unit.
Step 1 : Release the guide.
Step 2 : Push the traverse slide plate (rib), ensure both grooves
are opened.
Step 2 : Push the traverse slide plate (rib), ensure both grooves
are opened.
Step 3 : Slot the traverse unit at approximately 45° into the
mecha chassis as arrow shown.
mecha chassis as arrow shown.
Click on the first or last page to see other RX-D50EE service manuals if exist.