109 
16.5.17  Indoor Freeze-up Protection (H99) 
 
Malfunction Decision Conditions: 
During anti-freezing control in cooling operation, when the indoor refrigerant liquid temperature < 0°C. 
 
Malfunction Caused: 
1.  Faulty water pump. 
2.  Insufficient water flow rate in system. 
3.  Water leak in system. 
4.  2 way valve partially closed. 
5.  Clogged expansion valve or strainer. 
6.  Refrigerant shortage (refrigerant leakage). 
7.  Faulty indoor refrigerant liquid temperature sensor. 
8.  Faulty indoor unit PCB (main). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
110 
16.5.18  Outdoor High Pressure Switch Activate (F12) 
 
Malfunction Decision Conditions: 
During operation of cooling and heating, when pressure 4.5MPa and above is detected by outdoor high pressure 
switch. 
 
Malfunction Caused: 
1.  Dust accumulation on the outdoor unit heat exchanger. 
2.  Air short circuit at outdoor unit. 
3.  Faulty water pump. 
4.  Insufficient water flow rate in system. 
5.  Water leak in system. 
6.  2/3 way valve closed. 
7.  Clogged expansion valve or strainer. 
8.  Excessive refrigerant. 
9.  Faulty outdoor high pressure sensor and switch. 
10.  Faulty outdoor unit PCB. 
 
Abnormality Judgment: 
Continue 4 times in 20 minutes. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
111 
16.5.19  Compressor Rotation Failure (F14) 
 
Malfunction Decision Conditions: 
A compressor rotation failure is detected by checking the compressor running condition through the position 
detection circuit. 
 
Malfunction Caused: 
1.  Compressor terminal disconnect. 
2.  Faulty outdoor unit PCB (main). 
3.  Faulty compressor. 
 
Abnormality Judgment: 
Continue 4 times in 20 minutes. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
112 
16.5.20  Outdoor Fan Motor (DC Motor) Mechanism Locked (F15) 
 
Malfunction Decision Conditions: 
The rotation speed detected by the Hall IC of the fan motor during fan motor operation is used to determine 
abnormal fan motor (feedback of rotation > 2550rpm or < 50rpm). 
 
Malfunction Caused: 
1.  Operation stop due to short circuit inside the fan motor winding. 
2.  Operation stop due to breaking of wire inside the fan motor. 
3.  Operation stop due to breaking of fan motor lead wires. 
4.  Operation stop due to fan motor Hall IC malfunction. 
5.  Operation error due to faulty outdoor unit PCB. 
 
Abnormality Judgment: 
Continue 2 times in 30 minutes. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 