Model Name
U-2E18CBPG
Indoor Unit Combination
3.2kW + 3.2kW
Power Source
1 Phase, 230V, 50Hz (Power supply from outdoor unit)
Cooling Operation
Capacity
kW
5.2 (1.50 - 5.4)
Electrical
Data
Running Current
A
7.10
Power Input
kW
1.520 (0.250 - 1.580)
EER W/W
3.42
Noise
Sound Pressure Level
dB
49
Sound Power Level
dB
64
Heating Operation
Capacity
kW
5.6 (1.1 - 7.2)
Electrical
Data
Running Current
A
5.35
Power Input
kW
1.210 (0.210 - 1.700)
COP
W/W
4.63
Noise
Sound Pressure Level
dB
51
Sound Power Level
dB(A)
66
Maximum Current
A
12.0
Starting Current
A
7.10
Circuit Braker Capacity
A
15
Dimension
Height
mm
540
Width
mm
780 (+70)
Depth
mm
289
Net Weight
kg
38
Connection Cable
3+1 (Earth) ø1.5 mm
2
Pipe Length Range (1 room)
m
3 - 20
Maximum Pipe Length (Total Room)
m
30
Refrigerant Pipe Diameter Liquid Side
mm
6.35
Gas Side
mm
9.52
Compressor
Type
Scroll Type
Motor Type
DC Brushless (4-poles)
Rated Output
W
700
Air Circulation
Type
Propeller Fan
Motor Type
DC Brushless (8-poles)
Rated Output
W
40
Fan Speed
High (Cooling / Heating)
RPM
890 / 890
Heat Exchanger 
Type
Plate fin configuration forced draft type
Tube Material 
Copper
Fin Material
Aluminium
Row/Stage
2/20
FPI
19
Air Volume
High
Cooling
(Heating)
34.5 (31.0)
Refrigerant Control Device
Expansion Valve
Refrigerant Oil  
POE (RB-68A)
Refrigerant (R410A)
g
1450
7
8
3 Features
• Product
- A single OUTDOOR unit enable air conditioning of up to two separate rooms for U-2E15GBE, U-2E18CBPG.
Remarks for U-2E15GBE / U-2E18CBPG;
1. At least two indoor units must be connected.
2. The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable
capacity range of indoor unit. (as shown in the above table.)
Example: The indoor units’ combination below is possible to connect to U-2E15GBE. (Total nominal capacity of indoor
units is between 4.4kW to 5.0kW)
1) Two S-E7JKDW only. (Total nominal cooling capacity is 4.4kW)
2) One S-E7JKDW and one S-E9JKDW. (Total nominal cooling capacity is 5.0kW)