Panasonic U-2E15GBE / U-2E18CBPG Service Manual ▷ View online

Order No. PHAAM1004117C2
Air Conditioner
OUTDOOR UNIT
U-2E15GBE
U-2E18CBPG
TABLE OF CONTENTS
PAGE
PAGE
1 Safety Precautions----------------------------------------------- 2
2 Specifications 
----------------------------------------------------- 4
2.1. Outdoor Unit  ----------------------------------------------- 4
3 Features ------------------------------------------------------------- 8
4 Location of Controls and Components 
------------------- 9
4.1. Outdoor Unit ------------------------------------------------ 9
5 Dimensions--------------------------------------------------------10
5.1. Outdoor Unit -----------------------------------------------10
6 Refrigeration Cycle Diagram --------------------------------11
7 Block Diagram
----------------------------------------------------12
8 Wiring Connection Diagram 
---------------------------------13
8.1. Outdoor Unit -----------------------------------------------13
9 Electronic Circuit Diagram -----------------------------------15
9.1. Outdoor Unit -----------------------------------------------15
10 Printed Circuit Board-------------------------------------------16
10.1. Outdoor Unit -----------------------------------------------16
11 Installation Information----------------------------------------17
11.1. Check Points-----------------------------------------------17
11.2. The Shapes of the 3-Way Valve Caps of the
Outdoor Unit Have Changed.--------------------------17
11.3. Piping Length ----------------------------------------------18
12 Installation Instruction-----------------------------------------19
12.1. Select The Best Location -------------------------------19
12.2. Outdoor Unit----------------------------------------------- 20
13 Operation Control----------------------------------------------- 23
13.1. Simultaneous Operation Control  -------------------- 23
13.2. Compressor Operation Frequency ------------------ 24
13.3. Deice Operation ------------------------------------------ 24
13.4. Protection Control for All Operations---------------- 25
13.5. Protection Control for Cooling & Soft Dry
Operation--------------------------------------------------- 26
13.6. Protection Control for Heating Operation ---------- 27
14 Servicing Mode -------------------------------------------------- 28
14.1. Auto OFF/ON Button ------------------------------------ 28
14.2. Select Remote Control Transmission Code ------- 29
14.3.  Remote Control Button -------------------------------- 29
15 Troubleshooting Guide --------------------------------------- 30
15.1. Refrigeration cycle system----------------------------- 30
15.2. Breakdown self diagnosis function ------------------ 31
16 Disassembly and Assembly Instructions--------------- 35
16.1. Removing the Cabinet Top Plate and Cabinet
Front Plate ------------------------------------------------- 35
16.2. Removing the Control Board Cover ----------------- 35
16.3. Removing the Control Board -------------------------- 36
16.4. Removing the Propeller Fan and Fan Motor ------ 36
17 Technical Data --------------------------------------------------- 37
Please file and use this manual together with the service manual for Model No. S-E7JKDW  S-E9JKDW  S-XE9JKDW
S-E12JKDW  S-XE12JKDW  S-E15JKDW, Order No. PHAAM1004107C2.
2
17.1. Operation Characteristics ------------------------------ 37
18 Exploded View and Replacement Parts List ----------- 45
18.1. U-2E15GBE   U-2E18CBPG-------------------------- 45
1 Safety Precautions
• Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing.
• Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and
main circuit for the model installed.
• The caution items stated here must be followed because these important contents are related to safety. The meaning of each
indication used is as below.
Incorrect installation or servicing due to ignoring of the instruction will cause harm or damage, and the seriousness is classified
by the following indications.
The items to be followed are classified by the symbols:
• Carry out test running to confirm that no abnormality occurs after the servicing. Then, explain to user the operation, care and
maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
This indication shows the possibility of causing death or serious injury.
This indication shows the possibility of causing injury or damage to properties.
This indication shows the possibility of causing death or serious injury.
1.
Engage dealer or specialist for installation and servicing. If installation or servicing done by the user is defective, it will cause water leakage,
electrical shock or fire.
2.
Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical shock or fire. 
3.
Use the attached accessories parts and specified parts for installation and servicing. Otherwise, it will cause the set to fall, water properly
done, the set will drop and cause injury.
4.
Install at a strong and firm location which is able to withstand the set's weight. If the strength is not enough or installation is not properly
done, the set will drop and cause injury. 
5.
For electrical work, follow the local national wiring standard, regulation and the installation instruction. An independent circuit and single
outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 
6.
Use the specified cable and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no external force will
be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
7.
Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause
heat-up at connection point of terminal, fire or electrical shock.
8.
When connecting the piping, do not allow air or any substances other than the specified refrigerant to enter the refrigeration
cycle. Otherwise, this may lower the capacity, cause abnormally high pressure in the refrigeration cycle, and possibly result in
explosion and injury.
9.
Thickness of copper pipes used must be more than 0.8 mm. Never use copper pipes thinner than 0.8 mm.
10. It is desirable that the amount of residual oil is less than 40 mg/10 m.
11. Do not modify the length of the power supply cord or use of the extension cord, and do not share the single outlet with other
electrical appliances. Otherwise, it will cause fire or electrical shock.
3
1.
The equipment must be earthed. It may cause electrical shock if grounding is not perfect.
2.
Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding
of the unit, it may cause fire. 
3.
Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the
furniture. 
4.
Pb free solder has a higher melting point than standard solder; typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a high
temperature soldering iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).
Pb free solder will tend to splash when heated too high (about 1100°F/600°C).
1.
Selection of the installation location. Select an installation location which is rigid and strong enough to support or hold the unit, and select a
location for easy maintenance.
2.
Power supply connection to the conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following 
methods. Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. 
In some countries, permanent connection of this room air conditioner to the power supply is prohibited.
1. Power supply connection to the receptacle using a power plug. Use an approved power plug with earth pin for the connection to the
socket.
2. Power supply connection to a circuit breaker for the permanent connection. Use an approved circuit breaker for the permanent
connection. It must be a double pole switch with a minimum 3.5 mm contact gap.
3.
Do not release refrigerant during piping work for installation, servicing reinstallation and during repairing a refrigeration parts. Take care of
the liquid refrigerant, it may cause frostbite.
4.
Installation work. It may need two people to carry out the installation work.
5.
Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
4
2 Specifications
2.1.
Outdoor Unit 
* Specifications are subject to change without notice for further improvement.
Model Name
U-2E15GBE
Indoor Unit Combination
2.2kW + 2.2kW
Power Source
1 Phase, 230V, 50Hz (Power supply from outdoor unit)
Cooling Operation
Capacity
kW
4.5 (1.50 - 5.0)
Electrical
Data
Running Current
A
5.75
Power Input
kW
1.230 (0.250 - 1.350)
EER W/W
3.66
Noise
Sound Pressure Level
dB
47
Sound Power Level
dB
62
Heating Operation
Capacity
kW
5.4 (1.1 - 7.0)
Electrical
Data
Running Current
A
5.20
Power Input
kW
1.170 (0.210 - 1.670)
COP
W/W
4.62
Noise
Sound Pressure Level
dB
49
Sound Power Level
dB(A)
64
Maximum Current
A
12.0
Starting Current
A
5.75
Circuit Braker Capacity
A
15
Dimension
Height
mm
540
Width
mm
780 (+70)
Depth
mm
289
Net Weight
kg
38
Connection Cable
3+1 (Earth) ø1.5 mm
2
Pipe Length Range (1 room)
m
3 - 20
Maximum Pipe Length (Total Room)
m
30
Refrigerant Pipe Diameter Liquid Side
mm
6.35
Gas Side
mm
9.52
Compressor
Type
Scroll Type
Motor Type
DC Brushless (4-poles)
Rated Output
W
700
Air Circulation
Type
Propeller Fan
Motor Type
DC Brushless (8-poles)
Rated Output
W
40
Fan Speed
High (Cooling / Heating)
RPM
860 / 820
Heat Exchanger 
Type
Plate fin configuration forced draft type
Tube Material 
Copper
Fin Material
Aluminium
Row/Stage
2/20
FPI
19
Air Volume
High
Cooling
(Heating)
33.3 (28.5)
Refrigerant Control Device
Expansion Valve
Refrigerant Oil  
POE (RB-68A)
Refrigerant (R410A)
g
1450
Page of 47
Display

Panasonic U-2E15GBE / U-2E18CBPG Service Manual ▷ Download

  • DOWNLOAD Panasonic U-2E15GBE / U-2E18CBPG Service Manual ↓ Size: 2.48 MB | Pages: 47 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic U-2E15GBE / U-2E18CBPG in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic U-2E15GBE / U-2E18CBPG Air Conditioner. Information contained in Panasonic U-2E15GBE / U-2E18CBPG Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.