DOWNLOAD Panasonic CW-A91AE / CW-A121AE Service Manual ↓ Size: 6.67 MB | Pages: 21 in PDF or view online for FREE

Model
CW-A91AE CW-A121AE
Pages
21
Size
6.67 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
cw-a91ae-cw-a121ae.pdf
Date

Panasonic CW-A91AE / CW-A121AE Service Manual ▷ View online

12.1.1. Mechanical Thermostat (Cooling).
12.2.1.  CW-A91AE (CWA12176).
12.1.2. Mechanical Thermostat (Heating).
12.2.2.  CW-A121AE (Inner Protector).
12 Technical Data
12.1. Thermostat Characteristics.
12.2. Overload Protector Characteristics.
17
CW-A91AE / CW-A121AE
12.3.1.1. Cooling Characteristics Vs.
Outdoor Temperature.
12.3.2.1. Cooling Characteristics Vs.
Outdoor Temperature.
12.3.1.2. Heating Characteristics Vs.
Outdoor Temperature.
12.3.2.2. Heating Characteristics Vs.
Outdoor Temperature.
12.3. Operation Characteristics.
12.3.1. CW-A91AE
12.3.2. CW-A121AE
18
CW-A91AE / CW-A121AE
12.3.3. Heat Sensible Capacity Chart
12.3.3.1. CW-A91AE
230V
Outdoor Temp. (°C)
Indoor Wet
Bulb Temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0°C
2.66
2.02
0.94
2.48
1.93
1.01
2.31
1.86
1.09
2.10
1.76
1.17
19.0°C
2.68
1.03
19.5°C
2.92
2.11
0.96
2.73
2.03
1.03
2.54
1.95
1.11
2.31
1.86
1.19
22.0°C
3.18
2.19
0.98
2.97
2.10
1.05
2.77
2.03
1.13
2.51
1.94
1.21
220V
Outdoor Temp. (°C)
Indoor Wet
Bulb Temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0°C
2.65
2.01
0.90
2.48
1.93
0.97
2.30
1.85
1.03
2.09
1.76
1.11
19.0°C
2.67
0.98
19.5°C
2.91
2.10
0.91
2.72
2.02
0.98
2.53
1.94
1.05
2.30
1.85
1.13
22.0°C
3.17
2.18
0.93
2.96
2.10
1.00
2.76
2.02
1.07
2.50
1.93
1.16
12.3.3.2. CW-A121AE
230V
Outdoor Temp. (°C)
Indoor Wet
Bulb Temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0°C
3.39
2.57
1.36
3.17
2.47
1.46
2.95
2.37
1.56
2.68
2.25
1.68
19.0°C
3.42
1.48
19.5°C
3.72
2.69
1.38
3.48
2.59
1.49
3.24
2.49
1.59
2.94
2.37
1.71
22.0°C
4.06
2.79
1.41
3.79
2.69
1.51
3.53
2.59
1.62
3.21
2.47
1.74
220V
Outdoor Temp. (°C)
Indoor Wet
Bulb Temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0°C
3.37
2.56
1.25
3.15
2.45
1.34
2.93
2.36
1.43
2.67
2.24
1.55
19.0°C
3.40
1.36
19.5°C
3.70
2.68
1.27
3.46
2.57
1.37
3.22
2.48
1.46
2.93
2.36
1.57
22.0°C
4.04
2.78
1.29
3.77
2.67
1.39
3.51
2.58
1.49
3.19
2.46
1.60
19
CW-A91AE / CW-A121AE
13 Exploded View
(Note)
     • 
• 
• 
• 
The above exploded view is for the purpose of parts disassembly and replacement.
     • 
• 
• 
• 
The non-numbered parts are not kept as standard service parts.
20
CW-A91AE / CW-A121AE
Page of 21
Display