CAUTION 
11. 
Labelling 
 
Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. 
 
The label shall be dated and signed. 
 
Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant. 
12. 
Recovery 
 
When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all 
refrigerants are removed safely. 
 
When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. 
 
Ensure that the correct number of cylinders for holding the total system charge are available. 
 
All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the 
recovery of refrigerant). 
 
Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. 
 
Recovery cylinders are evacuated and, if possible, cooled before recovery occurs. 
 
The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall 
be suitable for the recovery of flammable refrigerants. 
 
In addition, a set of calibrated weighing scales shall be available and in good working order. 
 
Hoses shall be complete with leak-free disconnect couplings and in good condition. 
 
Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any 
associated electrical components are sealed to prevent ignition in the event of a refrigerant release. 
Consult manufacturer if in doubt. 
 
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste 
Transfer Note arranged. 
 
Do not mix refrigerants in recovery units and especially not in cylinders. 
 
If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain 
that flammable refrigerant does not remain within the lubricant. 
 
The evacuation process shall be carried out prior to returning the compressor to the suppliers. 
 
Only electric heating to the compressor body shall be employed to accelerate this process. 
 
When oil is drained from a system, it shall be carried out safely. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
10 
3. Specifications 
Model 
Indoor CS-Z25UD3EAW 
CS-Z35UD3EAW 
Outdoor CU-Z25UBEA 
CU-Z35UBEA 
Performance Test Condition 
EUROVENT 
EUROVENT 
Power Supply 
Phase, Hz 
Single, 50 
Single, 50 
V 230 
230 
 
Min. Mid. Max. Min. Mid. Max. 
Cooling 
Capacity 
kW 
0.85 2.50 3.20 0.85 3.50 4.00 
BTU/h 
2900  8530 10900 2900 11900 13600 
Kcal/h 
730 2150 2750 730 3010 3440 
Running 
Current 
– 2.70 –  – 4.10 – 
Input 
Power 
240 580 850 240 910 1.19k 
Annual 
Consumption kWh 
– 290 –  – 455 – 
EER 
W/W 
3.54 4.31 3.76 3.54 3.85 3.36 
BTU/hW  12.08 14.71 12.82 12.08 13.08 11.43 
Kcal/hW  3.04 3.71 3.24 3.04 3.31 2.89 
ErP 
Pdesign kW 
2.5 
3.5 
SEER (W/W) 
5.9 
5.8 
Annual 
Consumption 
kWh 148 
211 
Class  
A+ 
A+ 
Power 
Factor 
– 93 –  – 97 – 
Indoor Noise (H / L / QLo) 
dB-A 
33 / 27 / 24 
33 / 27 / 24 
Power Level dB 
49 / – 
49 / – 
Outdoor Noise (H / L) 
dB-A 
46 / – 
48 / – 
Power Level dB 
61 / – 
63 / – 
Heating
 
Capacity 
kW 
0.85 3.20 4.60 0.85 4.20 5.10 
BTU/h 
2900 10900 15700 2900 14300 17400 
Kcal/h 
730 2750 3960 730 3610 4390 
Running 
Current 
– 3.60 –  – 4.90 – 
Input 
Power 
230  800 1.25k 230 1.10k 1.42k 
COP 
W/W 
3.70 4.00 3.68 3.70 3.82 3.59 
BTU/hW  12.61 13.63 12.56 12.61 13.00 12.25 
Kcal/hW  3.17 3.44 3.17 3.17 3.28 3.09 
ErP 
Pdesign kW 
2.6 
2.8 
Tbivalent °C 
-10 
-10 
SCOP (W/W) 
4.2 
4.1 
Annual 
Consumption 
kWh 867 
956 
Class  
A+ 
A+ 
Power 
Factor 
– 97 –  – 98 – 
Indoor Noise (H / L / QLo) 
dB-A 
35 / 27 / 24 
35 / 27 / 24 
Power Level dB 
51 / – 
51 / – 
Outdoor Noise (H / L) 
dB-A 
47 / – 
48 / – 
Power Level dB 
62 / – 
63 / – 
Low Temp. : Capacity (kW) / I.Power (W) / COP 
3.33 / 1.11k / 3.00 
3.70 / 1.26k / 2.94 
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 
2.60 / 1.20k / 2.17 
3.00 / 1.25k / 2.40 
Max Current (A) / Max Input Power (W) 
5.6 / 1.25k 
6.6 / 1.42k 
Starting Current (A) 
3.60 
4.90 
 
11 
Model 
Indoor CS-Z25UD3EAW 
CS-Z35UD3EAW 
Outdoor CU-Z25UBEA 
CU-Z35UBEA 
Compressor 
Type 
 
Hermetic Motor (Rotary) 
Hermetic Motor (Rotary) 
Motor Type 
 
Brushless (6 poles) 
Brushless (6 poles) 
Output Power 
700 
700 
Indoor Fan
 
Type  
SIROCCO 
SIROCCO 
Material 
 
GFZ010A / GF20 
GFZ010A / GF20 
Motor Type 
 
DC / Transistor (8-poles) 
DC / Transistor (8-poles) 
Input Power 
– 
– 
Output Power 
51 
51 
Speed 
QLo 
Cool rpm 
800 
800 
Heat rpm 
790 
790 
Lo 
Cool rpm 
880 
880 
Heat rpm 
860 
860 
Me 
Cool rpm 
990 
1010 
Heat rpm 
980 
1000 
Hi 
Cool rpm 
1100 
1140 
Heat rpm 
1100 
1140 
SHi 
Cool rpm 
1150 
1190 
Heat rpm 
1150 
1190 
Outdoo
r Fa
n
 
Type 
 
Propeller Fan 
Propeller Fan 
Material  
PP 
PP 
Motor Type 
 
DC (8-poles) 
DC (8-poles) 
Input Power 
– 
– 
Output Power 
40 
40 
Speed Hi 
Cool rpm 
820 
850 
Heat rpm 
780 
830 
Moisture Removal 
L/h (Pt/h) 
1.5 (3.2) 
2.0 (4.2) 
Indoor 
Airflow 
QLo 
Cool m
3
/min (ft
3
/min.) 
7.4 (261) 
7.2 (254) 
Heat m
3
/min (ft
3
/min.) 
7.3 (258) 
7.1 (251) 
Lo 
Cool m
3
/min (ft
3
/min.) 
8.2 (290) 
8.2 (290) 
Heat m
3
/min (ft
3
/min.) 
8.0 (283) 
7.9 (279) 
Me 
Cool m
3
/min (ft
3
/min.) 
9.3 (328) 
9.5 (335) 
Heat m
3
/min (ft
3
/min.) 
9.3 (328) 
9.5 (335) 
Hi 
Cool m
3
/min (ft
3
/min.) 
10.5 (370) 
11.2 (395) 
Heat m
3
/min (ft
3
/min.) 
10.5 (370) 
11.2 (395) 
SHi 
Cool m
3
/min (ft
3
/min.) 
11.1 (392) 
11.7 (413) 
Heat m
3
/min (ft
3
/min.) 
11.1 (392) 
11.7 (413) 
Outdoor 
Airflow 
Hi 
Cool m
3
/min (ft
3
/min.) 
28.7 (1015) 
34.3 (1210) 
Heat m
3
/min (ft
3
/min.) 
27.2 (960) 
33.5 (1185) 
Refrigeration 
Cycle 
Control Device 
 
Expansion Valve 
Expansion Valve 
Refrigerant Oil 
cm
3
 
FW50S (320) 
FW50S (320) 
Refrigerant Type 
g (oz) 
R32, 880 (31.1) 
R32, 930 (32.8) 
F-Gas 
GWP 675 
675 
CO2eq (ton)  
(Precharged Amount /  
Maximum Charged Amount) 
0.594 / 0.678 
0.628 / 0.712 
Dimension 
Height (I/D / O/D) 
mm (inch) 
200 (7-7/8) / 542 (21-11/32) 
200 (7-7/8) / 619 (24-3/8) 
Width (I/D / O/D) 
mm (inch) 
750 (29-17/32) / 780 (30-23/32) 
750 (29-17/32) / 824 (32-15/32) 
Depth (I/D / O/D) 
mm (inch) 
640 (25-7/32) / 289 (11-13/32) 
640 (25-7/32) / 299 (11-25/32) 
12 
Model 
Indoor CS-Z25UD3EAW 
CS-Z35UD3EAW 
Outdoor CU-Z25UBEA 
CU-Z35UBEA 
Weight 
Net (I/D / O/D) 
kg (lb) 
19 (42) / 33 (73) 
19 (42) / 35 (77) 
Piping 
Pipe Diameter (Liquid / Gas) 
mm (inch) 
6.35 (1/4) / 9.52 (3/8) 
6.35 (1/4) / 9.52 (3/8) 
Standard length 
m (ft) 
5.0 (16.4) 
5.0 (16.4) 
Length range (min – max) 
m (ft) 
3 (9.8) ~ 20 (65.6) 
3 (9.8) ~ 20 (65.6) 
I/D & O/D Height different 
m (ft) 
15.0 (49.2) 
15.0 (49.2) 
Additional Gas Amount 
g/m (oz/ft) 
10 (0.1) 
10 (0.1) 
Length for Additional Gas 
m (ft) 
7.5 (24.6) 
7.5 (24.6) 
Drain Hose 
Inner Diameter 
mm  
16 
16 
Length mm 
117.5 
117.5 
Indoor Heat 
Exchanger 
Fin Material 
 
Aluminium (Pre Coat) 
Aluminium (Pre Coat) 
Fin Type 
 
Slit Fin 
Slit Fin 
Row × Stage × FPI 
 
3 × 12 × 18 
3 × 12 × 18 
Size (W × H × L) 
mm 
590 × 282 × 38.1 
590 × 282 × 38.1 
Outdoor 
Heat 
Exchanger 
Fin Material 
 
Aluminium 
Aluminium 
Fin Type 
 
Corrugated Fin 
Corrugated Fin 
Row × Stage × FPI 
 
2 × 24 × 19 
2 × 28 × 17 
Size (W × H × L) 
mm 
36.4 × 504 × 824.2:793.7 
36.38 × 588 × 856.3:827.7 
Air Filter 
Material  
– 
– 
Type  
– 
– 
Power Supply 
 
Outdoor 
Outdoor 
Power Supply Cord 
Nil 
Nil 
Thermostat 
 
Electronic Contol 
Electronic Contol 
Protection Device 
 
Electronic Contol 
Electronic Contol 
 
Dry Bulb 
Wet Bulb 
Dry Bulb 
Wet Bulb 
Indoor 
Operation 
Range 
Cooling 
Maximum 
°C 
32 23 32 23 
Minimum 
°C 
16 11 16 11 
Heating 
Maximum 
°C 
30 – 30 – 
Minimum 
°C 
16 – 16 – 
Outdoor 
Operation 
Range 
Cooling 
Maximum 
°C 
43 26 43 26 
Minimum 
°C 
-10 – -10 – 
Heating 
Maximum 
°C 
24 18 24 18 
Minimum 
°C 
-15 -16 -15 -16 
 
1. 
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air 
temperature of 35°C DRY BULB (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb). 
2. 
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F 
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb). 
3. 
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C. 
4. 
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C. 
5. 
Standby power consumption ≤10.0w (when switched OFF by remote control, except under self protection control). 
6. 
Specifications are subjected to change without prior notice for further improvement. 
 
 
 
 
 
 
 
 
 
 
 
 
 