Panasonic CS-Z20TKEW / CS-Z25TKEW / CS-Z35TKEW / CS-Z42TKEW / CS-Z50TKEW / CS-Z71TKEW / CS-XZ20TKEW / CS-XZ25TKEW / CS-XZ35TKEW / CS-XZ50TKEW / CU-Z20TKE / CU-Z25TKE / CU- / 35TKE / CU-Z42TKE / CU-Z50TKE / CU-Z71TKE / CU-Z20TKE / CU-Z25TKE / CU-Z35TKE / CU-Z50TKE Service Manual ▷ View online
25
6. Dimensions
6.1 Indoor
Unit
6.1.1
CS-Z20TKEW CS-Z25TKEW CS-Z35TKEW CS-Z42TKEW
CS-XZ20TKEW CS-XZ25TKEW CS-XZ35TKEW
CS-XZ20TKEW CS-XZ25TKEW CS-XZ35TKEW
(194)
919
295
2 ±0.5
2 ±0.5
194
45
61
60
60
139
149
(41-61)
410
16.4
264.6
Unit: mm
B
A
C
PIPE
HOLE
CENTER
HOLE
CENTER
PIPE
HOLE
CENTER
HOLE
CENTER
128mm TO
PIPE HOLE
CENTER
PIPE HOLE
CENTER
128mm TO
PIPE HOLE
CENTER
PIPE HOLE
CENTER
496.6
128
266
266
128
Right
piping
hole
piping
hole
Left
piping
hole
piping
hole
Installation
plate
plate
Indoor unit
external
dimensions
line
external
dimensions
line
460
460
43
95
<Top View>
<Front View>
<Bottom View>
<Rear View>
Relative position between the indoor unit and the installation plate <Front View>
<Side View>
<Side View>
Gas side
Liquid side
Liquid side
Left piping
hole
Air outlet
direction
Air intake
direction
Right piping
hole
22
<Remote Control>
160
59
<Remote Control Holder>
64
87
26
6.1.2
CS-Z50TKEW CS-Z71TKEW CS-XZ50TKEW
1120
302
1-2
1-2
236
42.6
60
60
60
135
135
(41-61)
410
Unit: mm
<Top View>
<Front View>
<Bottom View>
<Rear View>
Relative position between the indoor unit and the installation plate <Front View>
<Side View>
<Side View>
Gas side
Liquid side
Left piping
hole
Air outlet
direction
Air intake
direction
Right piping
hole
22
<Remote Control>
160
59
<Remote Control Holder>
64
87
Left
piping
hole
piping
hole
Right
piping
hole
piping
hole
Indoor unit
external
dimensions
line
external
dimensions
line
Installation
plate
plate
16.5
264.3
128
266
741.4
560
560
266
128
128
270
320
42.6
60
27
6.2 Outdoor
Unit
6.2.1
CU-Z20TKE CU-Z25TKE
(18)
69.5
61.6
542
289
39
570.3
22
(104.7)
67.6
780
85.5
155.2
34.3
60.5
104.9
Space necessary for
installation
Anchor Bolt Pitch
320
×
570
<Side View>
<Side View>
<Front View>
<Top View>
Unit: mm
2-way valve at Liquid side
(High Pressure)
(High Pressure)
3-way valve at Gas side
(Low Pressure)
(Low Pressure)
1000 mm
100 mm
100 mm
6.2.2
CU-Z35TKE CU-Z42TKE
<Top View>
<Front View>
<Side View>
<Side View>
Anchor Bolt Pitch
330 × 540
Space necessary for
installation
100 mm
100 mm
1000 mm
Unit : mm
3-way valve at Gas side
(Low Pressure)
(Low Pressure)
2-way valve at Liquid side
(High Pressure)
(High Pressure)
22
(124)
(62.6)
330
61
9
167
97
69
(2
0
)
62
32
540
160
824
68.7
37
299
28
6.2.3
CU-Z50TKE CU-Z71TKE
(25)
75
70.5
695
320
386
45
7.7
613
34.7
(131)
72
875
35
82
360.5
131
<Side View>
<Side View>
<Front View>
<Top View>
Unit: mm
2-way valve at Liquid side
(High Pressure)
(High Pressure)
3-way valve at Gas side
(Low Pressure)
(Low Pressure)
Anchor Bolt Pitch
360.5 × 613
Space necessary for
installation
100 mm
100 mm
1000 mm
Click on the first or last page to see other CS-Z20TKEW / CS-Z25TKEW / CS-Z35TKEW / CS-Z42TKEW / CS-Z50TKEW / CS-Z71TKEW / CS-XZ20TKEW / CS-XZ25TKEW / CS-XZ35TKEW / CS-XZ50TKEW / CU-Z20TKE / CU-Z25TKE / CU- / 35TKE / CU-Z42TKE / CU-Z50TKE / CU-Z71TKE / CU-Z20TKE / CU-Z25TKE / CU-Z35TKE / CU-Z50TKE service manuals if exist.