Panasonic CS-Z20TKEW / CS-Z25TKEW / CS-Z35TKEW / CS-Z42TKEW / CS-Z50TKEW / CS-Z71TKEW / CS-XZ20TKEW / CS-XZ25TKEW / CS-XZ35TKEW / CS-XZ50TKEW / CU-Z20TKE / CU-Z25TKE / CU- / 35TKE / CU-Z42TKE / CU-Z50TKE / CU-Z71TKE / CU-Z20TKE / CU-Z25TKE / CU-Z35TKE / CU-Z50TKE Service Manual ▷ View online
21
Multi Split Combination Possibility:
o A single outdoor unit enables air conditioning of up to two separate rooms for CU-2E12SBE, CU-2E15SBE,
CU-2E18SBE.
o A single outdoor unit enables air conditioning of up to three separate rooms for CU-3E23SBE, CU-3E18PBE.
CONNECTABLE INDOOR UNIT
CU-2E12SBE CU-2E15SBE CU-2E18SBE
CU-3E23SBE
CU-3E18PBE
ROOM
A B A B A B A B C A B C
Wall
1.6kW CS-MZ16TKE ●
●
●
●
●
●
●
●
●
●
●
●
2.0kW
CS-Z20TKEW
CS-XZ20TKEW
●
●
●
●
●
●
●
●
●
●
●
●
2.5kW
CS-Z25TKEW
CS-XZ25TKEW
●
●
●
●
●
●
●
●
●
●
●
●
3.5kW
CS-Z35TKEW
CS-XZ35TKEW
●
●
●
●
●
●
●
●
●
●
●
●
4.2kW CS-Z42TKEW – – – – ●
●
●
●
●
●
●
●
5.0kW
CS-Z50TKEW
CS-XZ50TKEW
– – – – ●
●
●
●
●
●
●
●
7.1kW CS-Z71TKEW – – – – – – – – – – – –
Capacity range of connectable units
From 3.2kW to
5.6kW
From 3.2kW to
5.6kW
From 3.2kW to
7.5kW
From 4.8kW to 10.0kW
From 4.8kW to 9.0kW
Pipe length
1 room maximum pipe length (m)
20
20
20
25
25
Allowable elevation (m)
10
10
10
15
15
Total allowable pipe length (m)
30
30
30
60
50
Total pipe length for maximum
chargeless length (m)
20 20 20
30
30
Additional gas amount over
chargeless length (g/m)
15 15 15
20
20
Note: “●” : Available
Remarks for CU-2E12SBE / CU-2E15SBE / CU-2E18SBE
1. The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor
1. The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor
unit. (as shown in the table above)
Example: The indoor units’ combination below is possible to connect to CU-2E15SBE. (Total nominal capacity of indoor units is between
3.2kW to 5.6kW)
1) Two CS-Z20TKEW only. (Total nominal cooling capacity is 4.0kW)
Example: The indoor units’ combination below is possible to connect to CU-2E15SBE. (Total nominal capacity of indoor units is between
3.2kW to 5.6kW)
1) Two CS-Z20TKEW only. (Total nominal cooling capacity is 4.0kW)
Remarks for CU-3E23SBE
1. The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor
1. The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor
unit. (as shown in the table above)
Example: The indoor units’ combination below is possible to connect to CU-3E23SBE. (Total nominal capacity of indoor units is between
4.8kW to 10.0kW)
1) Two CS-Z25TKEW only. (Total nominal cooling capacity is 5.0kW)
Example: The indoor units’ combination below is possible to connect to CU-3E23SBE. (Total nominal capacity of indoor units is between
4.8kW to 10.0kW)
1) Two CS-Z25TKEW only. (Total nominal cooling capacity is 5.0kW)
22
Multi Split Combination Possibility:
o A single outdoor unit enables air conditioning of up to four separate rooms for CU-4E23PBE, CU-4E27PBE.
o A single outdoor unit enables air conditioning of up to five separate rooms for CU-5E34PBE.
o A single outdoor unit enables air conditioning of up to five separate rooms for CU-5E34PBE.
CONNECTABLE INDOOR UNIT CU-4E23PBE
CU-4E27PBE
CU-5E34PBE
ROOM
A B C D A B C D A B C D E
Wall
1.6kW CS-MZ16TKE ●
●
●
●
●
●
●
●
●
●
●
●
●
2.0kW
CS-Z20TKEW
CS-XZ20TKEW
●
●
●
●
●
●
●
●
●
●
●
●
●
2.5kW
CS-Z25TKEW
CS-XZ25TKEW
●
●
●
●
●
●
●
●
●
●
●
●
●
3.5kW
CS-Z35TKEW
CS-XZ35TKEW
●
●
●
●
●
●
●
●
●
●
●
●
●
4.2kW CS-Z42TKEW ●
●
●
●
●
●
●
●
●
●
●
●
●
5.0kW
CS-Z50TKEW
CS-XZ50TKEW
●
●
●
●
●
●
●
●
●
●
●
●
●
7.1kW CS-Z71TKEW
– – – – ●
●
●
●
●
●
●
●
●
Capacity range of connectable units
From 4.8kW to 11.0kW
From 4.8kW to 13.6kW
From 4.8kW to 17.5kW
Pipe length
1 room maximum pipe length (m)
25
25
25
Allowable elevation (m)
15
15
15
Total allowable pipe length (m)
70
70
80
Total pipe length for maximum
chargeless length (m)
40 45
45
Additional gas amount over
chargeless length (g/m)
20 20
20
Note: “●” : Available
Remarks for CU-4E23PBE / CU-4E27PBE / CU-5E34PBE
1.
The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor
unit. (as shown in the table above)
Example: The indoor units’ combination below is possible to connect to CU-4E27PBE. (Total nominal capacity of indoor units is between
4.5kW to 13.6kW)
1) Two CS-Z25TKEW only. (Total nominal cooling capacity is 5.0kW)
unit. (as shown in the table above)
Example: The indoor units’ combination below is possible to connect to CU-4E27PBE. (Total nominal capacity of indoor units is between
4.5kW to 13.6kW)
1) Two CS-Z25TKEW only. (Total nominal cooling capacity is 5.0kW)
23
4. Features
Inverter Technology
o Wider output power range
o Energy
o Energy
saving
o Quick
Cooling
o Quick
Heating
o More precise temperature control
Environment Protection
o Non-ozone depletion substances refrigerant (R32)
Long Installation Piping
o Long piping up to 15 meters (0.75 ~ 1.75HP), 20 meters (2.0HP) and 30 meters (2.5HP) during single split
connection only
Easy to use remote control
Quality Improvement
o Random auto restart after power failure for safety restart operation
o Gas
o Gas
leakage
protection
o Prevent compressor reverse cycle
o Inner protector to protect compressor
o Noise prevention during soft dry operation
o Inner protector to protect compressor
o Noise prevention during soft dry operation
Operation Improvement
o Quiet mode to reduce the indoor unit operating sound
o Powerful mode to reach the desired room temperature quickly
o 24-hour timer setting
o Powerful mode to reach the desired room temperature quickly
o 24-hour timer setting
Serviceability Feature
o Activation and Deactivation Method for Heating Only Mode
o Breakdown Self Diagnosis function
o Breakdown Self Diagnosis function
24
5. Location of Controls and Components
5.1 Indoor
Unit
Front panel
Air Filters
Auto OFF/ON button
Use when remote control is misplaced
or a malfunction occurs.
Use when remote control is misplaced
or a malfunction occurs.
Vertical airflow direction louver
Do not adjust by hand.
Horizontal airflow direction louver
Do not adjust by hand.
Aluminium fin
Human activity
sensor
Sunlight Sensor and
Remote Control Receiver
Remote Control Receiver
Indicator
TIMER
ECONAVI
nanoe
POWER
(White)
(White)
(White)
(White)
5.2 Outdoor
Unit
5.3 Remote
Control
Timer setting
Airflow direction
selection
selection
Mild dry operation
nanoe operation
Fan speed selection
Transmitter
Operation mode
Sleep mode operation
Powerful/Quiet
operation
ECONAVI operation
Remote control
display
Clock setting
OFF/ON
Check
Temperature setting
Click on the first or last page to see other CS-Z20TKEW / CS-Z25TKEW / CS-Z35TKEW / CS-Z42TKEW / CS-Z50TKEW / CS-Z71TKEW / CS-XZ20TKEW / CS-XZ25TKEW / CS-XZ35TKEW / CS-XZ50TKEW / CU-Z20TKE / CU-Z25TKE / CU- / 35TKE / CU-Z42TKE / CU-Z50TKE / CU-Z71TKE / CU-Z20TKE / CU-Z25TKE / CU-Z35TKE / CU-Z50TKE service manuals if exist.