Panasonic CS-XE9EKE / CU-XE9EKE / CS-XE12EKE / CU-XE12EKE Service Manual ▷ View online
4
ATTENTION
1. Selection of the installation location. Select an installation location which is rigid and strong enough to support or hold the unit, and select a
location for easy maintenance.
2. Power supply connection to the conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following
methods.
Power supply point shall be the place where there is ease for ease for access for the power disconnection in case of emergency.
In some countries, permanent connection of this room air conditioner to the power supply is prohibited.
1. Power supply connection to the receptacle using a power plug. Use an approved power plug with earth pin for the connection to the
socket.
2. Power supply connection to a circuit breaker for the permanent connection. Use an approved circuit breaker for the permanent connec-
tion. It must be a double pole switch with a minimum 3.5 mm contact gap.
Power supply point shall be the place where there is ease for ease for access for the power disconnection in case of emergency.
In some countries, permanent connection of this room air conditioner to the power supply is prohibited.
1. Power supply connection to the receptacle using a power plug. Use an approved power plug with earth pin for the connection to the
socket.
2. Power supply connection to a circuit breaker for the permanent connection. Use an approved circuit breaker for the permanent connec-
tion. It must be a double pole switch with a minimum 3.5 mm contact gap.
3. Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigeration parts. Take care of
the liquid refrigerant, it may cause frostbite.
4. Installation work. It may need two people to carry out the installation work.
5. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
5. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
5
2 Specifications
2.1.
CS-XE9EKE CU-XE9EKE
Unit
CS-XE9EKE
CU-XE9EKE
Performance Test Condition
EUROVENT/AS
Power Source
(Phase, Voltage, Cycle)
ø, V, Hz
Single, 230 - 240, 50
Cooling Capacity
kW
2.60 (0.60 - 3.00)
kcal/h
2,240 (520 - 2,580)
Heating Capacity
kW
3.60 (0.60 - 6.10)
kcal/h
3,100 (520 - 5,250)
Moisture Removal
l/h (Pint/h)
1.6 (3.4)
Airflow Method
OUTLET
SIDE VIEW
TOP VIEW
INTAKE
Air Volume
Lo
m
3
/min (cfm)
Cooling; 7.3 (260)
—
Heating; 7.7 (270)
Me
m
3
/min (cfm)
Cooling; 8.9 (310)
—
Heating; 9.5 (340)
Hi
m
3
/min (cfm)
Cooling; 10.6 (370)
Cooling; 29.8 (1,050)
Heating; 11.7 (410)
SHi
m
3
/min (cfm)
Cooling; 11.3 (400)
—
Heating; 12.1 (430)
Noise Level
dB (A)
Cooling; High 39 - 39, Low 26 - 26
Cooling; High 46 - 46
Heating; High 40 - 40, Low 27 - 27
Heating; High 47 - 47
Power level dB
Cooling; High 50 - 50
Cooling; High 59 - 59
Heating; High 51 - 51
Heating; High 60 - 60
Electrical Data
Input Power
W
Cooling; 570 (120 - 700)
Heating; 810 (115 - 1,640)
Running Current
A
Cooling; 2.8 - 2.7
Heating; 3.8 - 3.7
Heating; 3.8 - 3.7
EER
W/W (kcal/hW)
Cooling; 4.56 (3.93)
COP
W/W (kcal/hW)
Heating; 4.44 (3.83)
Starting Current
A
3.8
Piping Connection Port
inch
G ; Half Union 3/8”
G ; 3-way valve 3/8”
(Flare piping)
inch
L ; Half Union 1/4”
L ; 2-way valve 1/4”
Pipe Size
inch
G ; (Gas side) 3/8”
G ; (Gas side) 3/8”
(Flare piping)
inch
L ; (Liquid side) 1/4”
L ; (Liquid side) 1/4”
Drain Hose
Inner diameter
mm
16
—
Length
m
0.65
—
Power Cord
Length
m
1.8
—
Number of core-wire
3 (1.5 mm
2
)
—
Dimensions
Height
inch (mm)
12 (305)
21 - 1/4 (540)
Width
inch (mm)
34 - 1/4 (870)
30 - 23/32 (780)
Depth
inch (mm)
9 - 1/32 (229)
11 - 3/8 (289)
Net Weight
lb (kg)
29 (13.0)
82 (37)
Compressor
Description
—
Hermetic Scroll
Motor
Type
—
Brushless (4-poles)
Rated
Output
W
—
750
6
Note:
• Specifications are subject to change without notice for further improvement.
Air Circulation
Description
Cross-flow Fan
Propeller Fan
Material
ASG20K1
P.P
Motor
Type
Transistor (8-poles)
Induction (8-poles)
Input
W
44.3
61.3
Rated
Output
W
30
40
Fan Speed Low (Cool/Heat)
rpm
800 / 850
—
Medium (Cool/Heat)
rpm
980 / 1,050
—
High (Cool/Heat)
rpm
1,170 / 1,280
790/800
SuperHigh (Cool/Heat)
rpm
1,250 / 1,340
—
Heat Exchanger
Description
Evaporator
Condenser
Tube material
Copper
Copper
Fin material
Aluminium (Pre Coat)
Aluminium
Fin Type
Slit Fin
Corrugated Fin
Row / Stage
(Plate fin configuration, forced draft)
2 / 15
2 / 24
FPI
20
17
Size (W
u H u L)
mm
610
u 315 u 25.4
718.4
u 504 u 36.4
689.8
Refrigerant Control Device
—
Exp. Valve
Refrigerations Oil
(cm
3
)
—
RB68A (400)
Refrigerant (R410A)
g (oz)
—
930 (32.8)
Thermostat
Electronic Control
—
Protection Device
—
Electronic Control
Capillary Tube
Length
mm
—
—
Flow Rate
I/min
—
—
Inner Diameter
mm
—
—
Air Filter
Material
PET
—
Style
Compressor Capacitor
PF, VAC
—
—
Fan Motor Capacitor
PF, VAC
—
—
Unit
CS-XE9EKE
CU-XE9EKE
7
2.2.
CS-XE12EKE CU-XE12EKE
Unit
CS-XE12EKE
CU-XE12EKE
Performance Test Condition
EUROVENT/AS
Power Source
(Phase, Voltage, Cycle)
ø, V, Hz
Single, 230 - 240, 50
Cooling Capacity
kW
3.50 (0.60 - 4.00)
kcal/h
3,010 (520 - 3,440)
Heating Capacity
kW
4.80 (0.60 - 6.70)
kcal/h
4,130 (520 - 5,760)
Moisture Removal
l/h (Pint/h)
2.0 (4.2)
Airflow Method
OUTLET
SIDE VIEW
TOP VIEW
INTAKE
Air Volume
Lo
m
3
/min (cfm)
Cooling; 8.2 (290)
—
Heating; 9.2 (320)
Me
m
3
/min (cfm)
Cooling; 10.1 (360)
—
Heating; 10.8 (380)
Hi
m
3
/min (cfm)
Cooling; 11.9 (420)
Cooling; 31.0 (1,090)
Heating; 12.7 (450)
SHi
m
3
/min (cfm)
Cooling; 12.6 (450)
—
Heating; 13.2 (470)
Noise Level
dB (A)
Cooling; High 42 - 42, Low 29 - 29
Cooling; High 48 - 48
Heating; High 42 - 42, Low 33 - 33
Heating; High 50 - 50
Power level dB
Cooling; High 53 - 53
Cooling; High 61 - 61
Heating; High 53 - 53
Heating; High 63 - 63
Electrical Data
Input Power
W
Cooling; 880 (120 - 1,100)
Heating; 1,220 (115 - 1,840)
Running Current
A
Cooling; 4.1 - 4.0
Heating; 5.6 - 5.4
EER
W/W (kcal/hW)
Cooling; 3.98 (3.42)
COP
W/W (kcal/hW)
Heating; 3.93 (3.39)
Starting Current
A
5.6
Piping Connection Port
inch
G ; Half Union 1/2”
G ; 3-way valve 1/2”
(Flare piping)
inch
L ; Half Union 1/4”
L ; 2-way valve 1/4”
Pipe Size
inch
G ; (Gas side) 1/2”
G ; (Gas side) 1/2”
(Flare piping)
inch
L ; (Liquid side) 1/4”
L ; (Liquid side) 1/4”
Drain Hose
Inner diameter
mm
16
—
Length
m
0.65
—
Power Cord
Length
m
1.8
—
Number of core-wire
3 (1.5 mm
2
)
—
Dimensions
Height
inch (mm)
12 (305)
21 - 1/4 (540)
Width
inch (mm)
34 - 1/4 (870)
30 - 23/32 (780)
Depth
inch (mm)
9 - 1/32 (229)
11 - 3/8 (289)
Net Weight
lb (kg)
29 (13.0)
82 (37)
Compressor
Description
—
Hermetic Scroll
Motor
Type
—
Brushless (4-poles)
Rated
Output
W
—
750
Air Circulation
Description
Cross-flow Fan
Propeller Fan
Material
ASG20K1
P.P
Motor
Type
Transistor (8-poles)
Induction (8-poles)
Input
W
44.3
65.9
Rated
Output
W
30
40
Fan Speed Low (Cool/Heat)
rpm
900 / 1,000
—
Medium (Cool/Heat)
rpm
1,100 / 1,180
—
High (Cool/Heat)
rpm
1,300 / 1,380
840/820
SuperHigh (Cool/Heat)
rpm
1,380 / 1,440
—