Panasonic CS-XE9EKE / CU-XE9EKE / CS-XE12EKE / CU-XE12EKE Service Manual ▷ View online

21
9.4.
Outdoor Unit
TOP VIEW
22
BOTTOM VIEW
23
10 Installation Instruction
10.1. Select The Best Location
• There should not be any heat source or steam near the unit.
• There should not be any obstacles blocking the air circula-
tion.
• A place where air circulation in the room is good.
• A place where drainage can be easily done.
• A place where noise prevention is taken into consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall, ceiling,
fence or other obstacles.
• Recommended installation height for indoor unit shall be at
least 2.5 m.
• If an awning is built over the unit to prevent direct sunlight or
rain, be careful that heat radiation from the condenser is not
obstructed.
• There should not be any animal or plant which could be
affected by hot air discharged.
• Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
• Do not place any obstacles which may cause a short circuit
of the discharged air.
• If piping length is over the rated length, additional refrigerant
should be added as shown in the table.
• This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
Indoor Unit
Outdoor Unit
Piping size
Rated
Length
(m)
Max
Elevation
(m)
Max.
Piping
Length
(m)
Additional
Refrigerant
(g/m)
Model
Gas
Liquid
XE9EKE
3/8”
1/4”
7.5
5
15
20
XE12EKE
1/2”
1/4”
7.5
5
15
20
Indoor/Outdoor Unit Installation Diagram
24
10.2. Indoor Unit
10.2.1.
How To Fix Installation Plate
The mounting wall is strong and solid enough to prevent it from
the vibration.
The centre of installation plate should be at more than 485 mm
at right and left of the wall.
The distance from installation plate edge to ceiling should more
than 75mm.
From installation plate left edge to unit's left side is 75 mm.
From installation plate right edge to unit's right is 85 mm.
1. Mount the installation plate on the wall with 5 screws or
more.
(If mounting the unit on the concrete wall, consider using
anchor bolts.)
• Always mount the installation plate horizontally by align-
ing the marking-off line with the thread and using a level
gauge.
2. Drill the piping plate hole with ø70 mm hole-core drill.
• Line according to the left and right side edge of the instal-
lation plate. The meeting point of the extended line is the
centre of the hole. Another method is by putting measur-
ing tape at position as shown in the diagram above. The
hole centre is obtained by measuring the distance
namely 107 mm and 58 mm for left and right edge of the
installation plate respectively.
• Drill the piping hole at either the right or the left and the
hole should be slightly slanted to the outdoor side.
10.2.2.
To Drill A Hole In The Wall And
Install A Sleeve Of Piping
1. Insert the piping sleeve to the hole.
2. Cut the sleeve until it extrudes about 15 mm from the
wall.
3. Fix the bushing to the sleeve.
4. Finish by sealing the sleeve with putty or caulking com-
pound at the final stage.
10.2.3.
Installing The Ventilation Hose
Carry out work carefully not to scratch the surface of the mobile panel.
Attached accessories
Ventilation hose connection diagram
:
:
:
For left side piping, piping connection for liquid should be
about 5 mm from this line.
For left side piping, piping connection for gas should be
about 55 mm from this line.
For left side piping, piping connection cable should be
about 750 mm from this line.
Caution
When the wall is hollow, please be sure to use the sleeve for tube
ass’y to prevent dangers caused by mice biting the connecting cable.