8.11.3. Oxygen Enrich System
A. Oxygen enrich tube connection
B. Oxygen Enrich control overview
When oxygen button at remote control is On, LED at air conditioner unit lights on & vacuum pump & outdoor fan operates.
*Note: Outdoor fan must run when vacuum pump operates.
29
CS-XC9CKT CU-XC9CKT / CS-XC12CKT CU-XC12CKT
C. Oxygen operation time diagram
1. Oxygen + compressor running mode (Cool, Dry)
T1 = 30 min, T2 = 3 min, T3 = 7 min
2. Oxygen only or Oxygen + Compressor stop mode (Ion, Fan)
T1 = 60 min, T2 = 2 min, T3 = 8 min
3. Oxygen demonstration mode
* Pump & outdoor fan “ON” continuously.
* Fan speed & airflow direction control vane angle follow previous setting.
* Indoor fan speed can be set by pressing fan speed selection button on remote control.
D. Oxygen Enrich Protection Control
1. Vacuum pump restart protection control
Purpose: To prevent starting noise if vacuum pump is started too often within short period.