Panasonic CS-W7NKD / CS-W9NKD / CS-W12NKD / CS-W18NKD / CS-W24NKD / CU-W7NKD / CU-W9NKD / CU-W12NKD / CU-W18NKD / CU-W24NKD Service Manual ▷ View online
21
7.4 CS-W24NKD
CU-W24NKD
22
8. Wiring Connection Diagram
8.1 CS-W7NKD CU-W7NKD CS-W9NKD CU-W9NKD
Resistance of Indoor Fan Motor Windings
Resistance of Compressor Windings
MODEL CS-W7NKD
CS-W9NKD
MODEL
CU-W7NKD
CU-W9NKD
CONNECTION CWA921434
CWA921434
CONNECTION
5RS084DAB21
5PS102DAH21
BLUE-YELLOW 351.3Ω 351.3Ω
C-R
4.794Ω 3.863Ω
YELLOW-RED 343.9Ω 343.9Ω
C-S
5.217Ω 3.309Ω
Note: Resistance at 20°C of ambient temperature.
Note: Resistance at 20°C of ambient temperature.
Resistance of Outdoor Fan Motor Windings
MODEL CU-W7NKD
CU-W9NKD
CONNECTION CWA951674
CWA951674
BLUE-YELLOW 396Ω 396Ω
YELLOW-RED 295Ω 295Ω
Note: Resistance at 20°C of ambient temperature.
23
8.2 CS-W12NKD
CU-W12NKD
Resistance of Indoor Fan Motor Windings
Resistance of Compressor Windings
MODEL CS-W12NKD
MODEL CU-W12NKD
CONNECTION CWA921434
CONNECTION
5PS132DAG21
BLUE-YELLOW 351.3Ω
C-R
2.798Ω
YELLOW-RED 343.9Ω
C-S
5.432Ω
Note: Resistance at 25°C of ambient temperature.
Note: Resistance at 20°C of ambient temperature.
Resistance of Outdoor Fan Motor Windings
MODEL CU-W12NKD
CONNECTION CWA951117J
BLUE-YELLOW 276Ω
YELLOW-RED 291Ω
Note: Resistance at 20°C of ambient temperature.
24
8.3 CS-W18NKD
CU-W18NKD
Resistance of Outdoor Fan Motor Windings
Resistance of Compressor Windings
MODEL CU-W18NKD
MODEL CU-W18NKD
CONNECTION CWA951385J
CONNECTION 5KS205DBB21
BLUE-YELLOW 93Ω
C-R
1.869Ω
YELLOW-ORANGE 124Ω
C-S
2.188Ω
YELLOW-RED 98Ω
Note: Resistance at 20°C of ambient temperature.
Note: Resistance at 25°C of ambient temperature.
Click on the first or last page to see other CS-W7NKD / CS-W9NKD / CS-W12NKD / CS-W18NKD / CS-W24NKD / CU-W7NKD / CU-W9NKD / CU-W12NKD / CU-W18NKD / CU-W24NKD service manuals if exist.