Panasonic CS-W18MKD / CS-W24MKD / CU-W18MKD / CU-W24MKD Service Manual ▷ View online
49
Error Detection Control
When e-ion indicator blink, it indicates error listed below:
o
o
Active e-ion Air Purifying system PCB main connector open:
Judgment
Method
During e-ion operation (include during Patrol operation), Active e-ion Air Purifying system main
connector to PCB is opened.
Troubleshooting
Methods
Connect the connector or stop operation (include during Patrol operation) to cancel the blinking.
o
Abnormal Discharge error:
Judgment
Method
During e-ion operation, feedback voltage is-Lo (at microcontroller) is detected, it is judged abnormal
discharge and stops power supplies to the Active e-ion Air Purifying system.
Abnormal discharge is caused by ionizer or filter’s high voltage power supply short-circuits due to
water or dust adhesion, and so forth.
When abnormal discharge occurred, every 30 minutes the unit supplies power to the Active e-ion Air
Purifying system.
When abnormal discharge occurs for 24 times continuously, e-ion indicator blinks (not applicable for
e-ion Check Mode, where the error will shows immediately despite the 24 times counter)
Troubleshooting
Method
Press “PATROL/e-ion” button or “OFF/ON” button to stop the operation and check the Active e-ion
Air Purifying system main connector to PCB.
After that, press “e-ion” button again to confirm the e-ion indicator not blinking.
The 24 times counter will be clear after 10 minutes of normal operation or when operation stops.
Error
Reset
Method
Press “OFF/ON” button to OFF the operation.
Press AUTO OFF/ON button at indoor unit to OFF the operation.
OFF Timer activates
Power supply reset
o
Active e-ion Air Purifying system breakdown error:
Judgment
Method
When hi-feedback voltage (at microcontroller) supplied to filter during e-ion stop, Active e-ion Air
Purifying system breakdown error shows immediately.
It is due to indoor PCB or filter’s high voltage power supply damage.
Operations except e-ion continue. Both Timer indicator and e-ion indicator blink.
Troubleshooting
Method
Press “PATROL/e-ion” button or “OFF/ON” button to stop the operation.
Change main circuit board or filter’s high voltage power supply.
When lo-feedback voltage supplied to Active e-ion Air Purifying system during e-ion operation, e-ion
indicator and Timer indicator stop blinking.
50
12.16 ECONAVI and AUTO COMFORT Operation
A Pyoelectric infrared sensor is used to detect injection strength variation of infrared at setting area to determine
the presence or absence of human and its activity level. Human detection area is shown in figure below:
ECONAVI & AUTO COMFORT operation – Human presence/absence detection outlined
flow
Process infrared sensor output signal
Human detection (movement) every 3 seconds.
▼
Human detection records
Records human detection (movement) result for 30 seconds and determine its activity level i.e. Hi/Lo.
▼
Presence / absence detection
Compares current and previous human detection result every 30 seconds to determine the presence
or absence of human.
or absence of human.
▼
Presence / absence determination
Based on human presence / absence detection, if human presence detection showed within 30
minutes, it is recognised that human is present. If human absence detection showed continuously for
more than 30 minutes, it is recognised that no human is present.
minutes, it is recognised that human is present. If human absence detection showed continuously for
more than 30 minutes, it is recognised that no human is present.
ECONAVI & AUTO COMFORT Sensor abnormality detection
(1) Connector pulled out (disconnected), Wire cut Abnormality (Fix Output at Hi)
c
Abnormal judgment start condition.
Start from ECONAVI & AUTO COMFORT Sensor power ON, and end after 30 seconds.
d
d
Control content.
Judge ECONAVI & AUTO COMFORT Sensor power level every 100ms.
e
e
Abnormal Judgment condition.
When ECONAVI & AUTO COMFORT Sensor has continues for 25 seconds Hi level.
(2) Circuit Abnormal (Fix Output Lo)
c
Abnormal judgment start condition.
After ECONAVI & AUTO COMFORT Sensor unit power ON, and after pressed 70 seconds.
d
d
Control content.
Judge ECONAVI & AUTO COMFORT Sensor power level every 100ms.
e
e
Abnormal Judgment condition.
When ECONAVI & AUTO COMFORT Sensor has continues at Lo level for 25 seconds.
(3) Abnormal treatment
Any one of the above self-diagnosis result is abnormal
Abnormal counter +1 and ECONAVI & AUTO COMFORT Sensor power supply OFF.
After ECONAVI & AUTO COMFORT Sensor unit power is OFF for 5 seconds, Retry the ECONAVI &
AUTO COMFORT operation.
When Abnormal counter reach 4 counts, ECONAVI & AUTO COMFORT sensor abnormality is confirmed.
(Abnormal counter is cleared when sensor power ON and maintain normal for 120 seconds and above or
Clear Abnormal counter by power reset)
Clear Abnormal counter by power reset)
Save ECONAVI & AUTO COMFORT Sensor Abnormality H59 (no Timer LED blinking).
ECONAVI & AUTO COMFORT Sensor operation OFF, but ECONAVI & AUTO COMFORT LED maintain
ON.
The unit still operate as normal.
Sensor error counter can be cleared only after power supply reset or AC Reset button on the remote
control is pressed.
51
ECONAVI & AUTO COMFORT Demo Mode
Press “Set” button continuously for 15 seconds by using pointer during Air Conditioner is OFF condition
to enter internal setting mode.
Press “Timer Decrement" button to select “EC demo”.
Press “Timer Set” button to toggle ECONAVI & AUTO COMFORT Demo mode.
Short "beep": Turn ON ECONAVI & AUTO COMFORT Demo mode.
Long "beep": Turn OFF ECONAVI & AUTO COMFORT Demo mode.
SET
SET
Transmit Patrol default OFF/ON code
(Buzzer: OFF:Long Beep, ON:Short Beep)
(Buzzer: OFF:Long Beep, ON:Short Beep)
Press continously for 15s
SET
Transmit Patrol demo code
(Buzzer: OFF:Long Beep, ON:Short Beep)
(Buzzer: OFF:Long Beep, ON:Short Beep)
SET
Transmit ECO demo code
(Buzzer: OFF:Long Beep, ON:Short Beep)
(Buzzer: OFF:Long Beep, ON:Short Beep)
SET
Transmit check code
(Buzzer:Short Beep)
(Buzzer:Short Beep)
Control details:
During ECONAVI & AUTO COMFORT Demo mode, operation LED ON and horizontal vane will set to Auto
Swing.
When Hi activity judge, Fan speed change to Hi Fan and ECONAVI & AUTO COMFORT LED ON.
When Lo activity judge, Fan speed change to Lo Fan and ECONAVI & AUTO COMFORT LED OFF.
No setting temperature adjustment.
52
During ECONAVI & AUTO COMFORT operation, the internal setting temperature and fan speed are adjusted in
order to provide comfort and energy saving.
ECONAVI Start condition.
Press ECONAVI button.
ECONAVI Stop condition.
Press ECONAVI button again.
OFF Timer activates.
Press OFF/ON button to turn off the air conditioner.
Press AUTO OFF/ON button to turn off the air conditioner.
Press POWERFUL/QUIET button.
AUTO COMFORT Start condition.
Press AUTO COMFORT button.
AUTO COMFORT Stop condition.
Press AUTO COMFORT button again.
OFF Timer activates.
Press OFF/ON button to turn off the air conditioner.
Press AUTO OFF/ON button to turn off the air conditioner.
Press POWERFUL/QUIET button.
ECONAVI & AUTO COMFORT operation could ON when any of the following conditions is fulfilled:
During forced cooling or forced heating operation.
During e-ion or individual patrol operation.
Power Failure
ECONAVI & AUTO COMFORT operation will be resuming after recovered from power failure.
Timer Operation
When unit is turn on by ON Timer and ECONAVI & AUTO COMFORT operation is ON during previous
operation before OFF, ECONAVI & AUTO COMFORT operation will not be ON automatically.
When unit is turn on by ON Timer and ECONAVI & AUTO COMFORT operation is OFF during previous
operation before OFF, ECONAVI & AUTO COMFORT operation will not be ON automatically.
Other Information
ECONAVI & AUTO COMFORT, Powerful, Quiet and Mild Dry Cooling cannot be operated at the same
time.
ECONAVI & AUTO COMFORT sensor initialized time is 70 seconds from power supplied to ECONAVI &
AUTO COMFORT sensor, or 70 seconds from the operation start.
Heating Mono Sensor