Resistance of Indoor Fan Motor Windings
MODEL
CS-VA75KE
CONNECTION
CWA921033
YELLOW-BLUE
707.1
YELLOW-BROWN
71.1
BROWN-ORANGE
64.7
ORANGE-WHITE
15.7
WHITE-RED
116.2
Resistance of Outdoor Fan Motor Windings
MODEL
CU-VA75KE
CONNECTION
CWA95245
BLUE-YELLOW
260.5
YELLOW-RED
446.0
Resistance of Compressor Windings
MODEL
CU-VA75KE
CONNECTION
5RS080DAA
C-R
5.807
C-S
9.304
7 Wiring Diagram
17
CS-VA75KE CU-VA75KE / CS-VA95KE CU-VA95KE / CS-VA125KE CU-VA125KE
REMARKS
B
: BLUE
BR
: BROWN
BL
: BLACK
W
: WHITE
R
: RED
O
: ORANGE
P
: PINK
Y/G
: YELLOW/GREEN
Resistance of Indoor Fan Motor Windings
MODEL
CS-VA95KE
CONNECTION
CWA921043
YELLOW-BLUE
451.2
YELLOW-BROWN
86.7
BROWN-ORANGE
98.4
ORANGE-WHITE
51.5
WHITE-RED
240.8
Resistance of Outdoor Fan Motor Windings
MODEL
CU-VA95KE
CONNECTION
CWA95245
BLUE-YELLOW
260.5
YELLOW-RED
446.0
Resistance of Compressor Windings
MODEL
CU-VA95KE
CONNECTION
5PS112DAA
C-R
3.166
C-S
4.573
18
CS-VA75KE CU-VA75KE / CS-VA95KE CU-VA95KE / CS-VA125KE CU-VA125KE
REMARKS
B
: BLUE
BR
: BROWN
BL
: BLACK
W
: WHITE
R
: RED
O
: ORANGE
P
: PINK
Y/G
: YELLOW/GREEN
Resistance of Indoor Fan Motor Windings
MODEL
CS-VA125KE
CONNECTION
CWA921031
YELLOW-BLUE
450.7
YELLOW-BROWN
68.2
BROWN-ORANGE
56.7
ORANGE-WHITE
56.9
WHITE-RED
102.0
Resistance of Outdoor Fan Motor Windings
MODEL
CU-VA125KE
CONNECTION
CWA95245
BLUE-YELLOW
260.5
YELLOW-RED
446.0
Resistance of Compressor Windings
MODEL
CU-VA125KE
CONNECTION
5KS150DAA
C-R
2.206
C-S
3.529
19
CS-VA75KE CU-VA75KE / CS-VA95KE CU-VA95KE / CS-VA125KE CU-VA125KE
Cooling in operation according to Remote Control setting.
Time Delay Safety Control (3 minutes)
7 minutes Time Save Control
Starting Current Control
Anti-Freezing Control
  • 
If the temperature of the indoor heat exchanger falls
continuously below 2°C for 4 minutes or more, the
compressor turns off to protect the indoor heat exchanger
from freezing. The fan speed setting remains the same.
  • 
Compressor will restart again when the indoor heat
exchanger temperature rises to 10°C (Recovery).
3 minutes waiting of Time Delay Safety Control is valid for
Cooling Operation.
Compressor Reverse Rotation Protection Control
8 Operation Details
8.1. Cooling Mode Operation
  • 
When the compressor is stopped by Remote Control, it restarts after 3 minutes when it is turned ON by Remote Control.
  • 
When the setting temperature is reached during cooling operation, the compressor stops and it will not start for 3 minutes.
  • 
The compressor will start automatically if it has stopped for 7 minutes even if the room temperature is between the compressor
ON temperature and OFF temperature.
  • 
When the compressor, outdoor fan motor & indoor fan motor are simultaneously started, the indoor fan motor will operate 1.6
second later.
  • 
If the compressor is operating continuously for 5 minutes or longer and the temperature difference between intake air and
indoor heat exchanger is 2.5°C or less for 2 minutes, compressor will stop and restart automatically.
(Time Delay Safety Control is valid)
s
T = Intake air temperature - Indoor heat exchanger temperature
This is to protect reverse rotation of the compressor when there is a instantaneous power failure.
20
CS-VA75KE CU-VA75KE / CS-VA95KE CU-VA95KE / CS-VA125KE CU-VA125KE
Page of 111
Display

Click on the first or last page to see other CS-VA75KE / CS-VA95KE / CS-VA125KE / CU-VA75KE / CU-VA95KE / CU-VA125KE service manuals if exist.