DOWNLOAD Panasonic CS-UE7RKD / CS-UE9RKD / CS-UE12RKD / CS-UE18RKD / CU-UE7RKD / CU-UE9RKD / CU-UE12RKD / CU-UE18RKD Service Manual ↓ Size: 12.57 MB | Pages: 127 in PDF or view online for FREE

Model
CS-UE7RKD CS-UE9RKD CS-UE12RKD CS-UE18RKD CU-UE7RKD CU-UE9RKD CU-UE12RKD CU-UE18RKD
Pages
127
Size
12.57 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-ue7rkd-cs-ue9rkd-cs-ue12rkd-cs-ue18rkd-cu-ue7rk.pdf
Date

Panasonic CS-UE7RKD / CS-UE9RKD / CS-UE12RKD / CS-UE18RKD / CU-UE7RKD / CU-UE9RKD / CU-UE12RKD / CU-UE18RKD Service Manual ▷ View online

13 
Model 
Indoor 
CS-UE12RKD 
Outdoor 
CU-UE12RKD 
Piping 
Pipe Diameter (Liquid / Gas) 
mm (inch) 
6.35 (1/4) / 9.52 (3/8) 
Standard length 
m (ft) 
5.0 (16.4) 
Length range (min – max) 
m (ft) 
3 (9.8) ~ 15 (49.2) 
I/D & O/D Height different 
m (ft) 
15.0 (49.2) 
Additional Gas Amount 
g/m (oz/ft) 
20 (0.2) 
Length for Additional Gas 
m (ft) 
7.5 (24.6) 
Drain Hose 
Inner Diameter 
mm  
16.7 
Length 
mm 
650 
Indoor Heat 
Exchanger 
Fin Material 
 
Aluminium (Pre Coat) 
Fin Type 
 
Slit Fin 
Row × Stage × FPI 
 
2 × 15 × 17 
Size (W × H × L) 
mm 
610 × 315 × 25.4 
Outdoor 
Heat 
Exchanger 
Fin Material 
 
Aluminium (Pre Coat) 
Fin Type 
 
Corrugated Fin 
Row × Stage × FPI 
 
2 × 24 × 17 
Size (W × H × L) 
mm 
36 × 504 × 713:684 
Air Filter 
Material 
 
Polypropelene 
Type 
 
One-touch 
Power Supply 
 
Outdoor 
Power Supply Cord 
Nil 
Thermostat 
 
Nil 
Protection Device 
 
Nil 
 
Dry Bulb 
Wet Bulb 
Indoor 
Operation 
Range 
Cooling 
Maximum °C 
32 
23 
Minimum °C 
16 
11 
Heating 
Maximum °C 
30 
– 
Minimum °C 
16 
– 
Outdoor 
Operation 
Range 
Cooling 
Maximum °C 
43 
26 
Minimum °C 
10 
– 
Heating 
Maximum °C 
24 
18 
Minimum °C 
-5 
-6 
 
1. 
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air 
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 
2. 
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb 
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb) 
3. 
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor 2/1°C. 
4. 
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor -7/-8°C. 
5. 
Standby power consumption ≤ 2.0W (when switched OFF by remote control, except under self-protection control). 
6. 
Specifications are subjected to change without prior notice for further improvement. 
7. 
Maximum heating capacity shown are the values based on powerful operation. 
8. 
If the EUROVENT Certified models can be operated under the “extra-low” temperature condition, -7°C DB and -8°C WB temperature with 
rated voltage 230V shall be used. 
9. 
The annual consumption is calculated by multiplying the input power by an average of 500 hours per year in cooling mode. 
10.  SEER and SCOP classification is at 230V only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating 
season. Other fiche data indicates in an attached sheet. 
 
 
 
 
 
 
 
 
 
14 
Model 
Indoor 
CS-UE18RKD 
Outdoor 
CU-UE18RKD 
Performance Test Condition 
JIS 
Power Supply 
Phase, Hz 
Single, 50 
220 
230 
 
Min. 
Mid. 
Max. 
Min. 
Mid. 
Max. 
Cooling 
Capacity 
kW 
0.98 
5.00 
5.60 
0.98 
5.00 
5.60 
BTU/h 
3340 
17100 
19100 
3340 
17100 
19100 
kcal/h 
840 
4300 
4820 
840 
4300 
4820 
Running Current 
– 
7.20 
– 
– 
6.90 
– 
Input Power 
285 
1.54k 
1.75k 
285 
1.54k 
1.75k 
Annual Consumption 
kWh 
– 
770 
– 
– 
770 
– 
EER 
W/W 
3.44 
3.25 
3.20 
3.44 
3.25 
3.20 
BTU/hW 
11.72 
11.10 
10.91 
11.72 
11.10 
10.91 
kcal/hW 
2.95 
2.79 
2.75 
2.95 
2.79 
2.75 
Power Factor 
– 
97 
– 
– 
97 
– 
Indoor Noise (H/L/QLo) 
dB-A 
44 / 37 / 34 
44 / 37 / 34 
Power Level dB 
60 / 53 / 50 
60 / 53 / 50 
Outdoor Noise 
dB-A 
48 
48 
Power Level dB 
63 
63 
Heating
 
Capacity 
kW 
0.98 
5.40 
7.70 
0.98 
5.40 
7.70 
BTU/h 
3340 
18400 
26300 
3340 
18400 
26300 
kcal/h 
840 
4640 
6620 
840 
4640 
6620 
Running Current 
– 
7.00 
– 
– 
6.70 
– 
Input Power 
350 
1.47k 
2.30k 
350 
1.47k 
2.30k 
COP 
W/W 
2.80 
3.67 
3.35 
2.80 
3.67 
3.35 
BTU/hW 
9.54 
12.52 
11.43 
9.54 
12.52 
11.43 
kcal/hW 
2.40 
3.16 
2.88 
2.40 
3.16 
2.88 
Power Factor 
– 
95 
– 
– 
95 
– 
Indoor Noise (H/L/QLo) 
dB-A 
44 / 37 / 34 
44 / 37 / 34 
Power Level dB 
60 / 53 / 50 
60 / 53 / 50 
Outdoor Noise 
dB-A 
49 
49 
Power Level dB 
64 
64 
Low Temp. : Capacity (kW) / I.Power (W) / COP 
5.58 / 2.04k / 2.74 
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 
4.79 / 2.09k / 2.29 
Max Current (A) / Max Input Power (W) 
10.1 / 2.30k 
Starting Current (A) 
7.20 
Compressor 
Type 
 
Hermetic Motor / Rotary 
Motor Type 
 
Brushless (4-poles) 
Output Power 
900 
 
 
 
 
 
 
 
 
 
 
 
15 
Model 
Indoor 
CS-UE18RKD 
Outdoor 
CU-UE18RKD 
Indoor 
F
an
 
Type 
 
Cross-Flow Fan 
Material 
 
ASG20K1 
Motor Type 
 
DC / Transistor (8 poles) 
Input Power 
94.8 
Output Power 
40 
Speed 
QLo 
Cool 
rpm 
880 
880 
Heat 
rpm 
990 
990 
Lo 
Cool 
rpm 
960 
960 
Heat 
rpm 
1070 
1070 
Me 
Cool 
rpm 
1080 
1080 
Heat 
rpm 
1190 
1190 
Hi 
Cool 
rpm 
1200 
1200 
Heat 
rpm 
1310 
1310 
SHi 
Cool 
rpm 
1390 
1390 
Heat 
rpm 
1430 
1430 
Outdoo
r Fa
n
 
Type 
 
Propeller Fan 
Material 
 
PP 
Motor Type 
 
DC (8 poles) 
Input Power 
– 
Output Power 
40 
Speed 
Hi 
Cool 
rpm 
860 
Heat 
rpm 
850 
Moisture Removal 
L/h (Pt/h) 
2.8 (5.9) 
Indoor 
Airflow 
QLo 
Cool 
m
3
/min (ft
3
/min) 
11.37 (402) 
11.37 (402) 
Heat 
m
3
/min (ft
3
/min) 
13.05 (461) 
13.05 (461) 
Lo 
Cool 
m
3
/min (ft
3
/min) 
12.59 (445) 
12.59 (445) 
Heat 
m
3
/min (ft
3
/min) 
14.28 (504) 
14.28 (504) 
Me 
Cool 
m
3
/min (ft
3
/min) 
14.43 (510) 
14.43 (510) 
Heat 
m
3
/min (ft
3
/min) 
16.11 (569) 
16.11 (569) 
Hi 
Cool 
m
3
/min (ft
3
/min) 
16.3 (575) 
Heat 
m
3
/min (ft
3
/min) 
17.9 (630) 
SHi 
Cool 
m
3
/min (ft
3
/min) 
19.17 (677) 
19.17 (677) 
Heat 
m
3
/min (ft
3
/min) 
19.78 (699) 
19.78 (699) 
Outdoor 
Airflow 
Hi 
Cool 
m
3
/min (ft
3
/min) 
34.4 (1215) 
34.4 (1215) 
Heat 
m
3
/min (ft
3
/min) 
34.0 (1200) 
34.0 (1200) 
Refrigeration 
Cycle 
Control Device 
 
Expansion Valve 
Refrigerant Oil 
cm
3
 
FV50S (450) 
Refrigerant Type 
g (oz) 
R410A, 1.43k (50.5) 
Dimension 
Height (I/D / O/D) 
mm (inch) 
290 (11-7/16) / 619 (24-3/8) 
Width (I/D / O/D) 
mm (inch) 
1070 (42-5/32) / 824 (32-15/32) 
Depth (I/D / O/D) 
mm (inch) 
240 (9-15/32) / 299 (11-25/32) 
Weight 
Net (I/D / O/D) 
kg (lb) 
11 (24) / 38 (84) 
 
 
 
 
 
 
16 
Model 
Indoor 
CS-UE18RKD 
Outdoor 
CU-UE18RKD 
Piping 
Pipe Diameter (Liquid / Gas) 
mm (inch) 
6.35 (1/4) / 12.70 (1/2) 
Standard length 
m (ft) 
5.0 (16.4) 
Length range (min – max) 
m (ft) 
3 (9.8) ~ 15 (49.2) 
I/D & O/D Height different 
m (ft) 
15.0 (49.2) 
Additional Gas Amount 
g/m (oz/ft) 
20 (0.2) 
Length for Additional Gas 
m (ft) 
7.5 (24.6) 
Drain Hose 
Inner Diameter 
mm  
16.7 
Length 
mm 
650 
Indoor Heat 
Exchanger 
Fin Material 
 
Aluminium (Pre Coat) 
Fin Type 
 
Slit Fin 
Row × Stage × FPI 
 
2 × 15 × 17 
Size (W × H × L) 
mm 
810 × 315 × 25.4 
Outdoor 
Heat 
Exchanger 
Fin Material 
 
Aluminium (Pre Coat) 
Fin Type 
 
Corrugated Fin 
Row × Stage × FPI 
 
2 × 28 × 17 
Size (W × H × L) 
mm 
36.4 × 588 × 856.3:827.7 
Air Filter 
Material 
 
Polypropelene 
Type 
 
One-touch 
Power Supply 
 
Indoor 
Power Supply Cord 
Nil 
Thermostat 
 
Nil 
Protection Device 
 
Nil 
 
Dry Bulb 
Wet Bulb 
Indoor 
Operation 
Range 
Cooling 
Maximum °C 
32 
23 
Minimum °C 
16 
11 
Heating 
Maximum °C 
30 
– 
Minimum °C 
16 
– 
Outdoor 
Operation 
Range 
Cooling 
Maximum °C 
43 
26 
Minimum °C 
10 
– 
Heating 
Maximum °C 
24 
18 
Minimum °C 
-5 
-6 
 
1. 
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air 
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 
2. 
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb 
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb) 
3. 
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor 2/1°C. 
4. 
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor -7/-8°C. 
5. 
Standby power consumption ≤ 2.0W (when switched OFF by remote control, except under self-protection control). 
6. 
Specifications are subjected to change without prior notice for further improvement. 
7. 
Maximum heating capacity shown are the values based on powerful operation. 
8. 
If the EUROVENT Certified models can be operated under the “extra-low” temperature condition, -7°C DB and -8°C WB temperature with 
rated voltage 230V shall be used. 
9. 
The annual consumption is calculated by multiplying the input power by an average of 500 hours per year in cooling mode. 
10.  SEER and SCOP classification is at 230V only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating 
season. Other fiche data indicates in an attached sheet. 
 
 
 
 
 
 
Page of 127
Display

Click on the first or last page to see other CS-UE7RKD / CS-UE9RKD / CS-UE12RKD / CS-UE18RKD / CU-UE7RKD / CU-UE9RKD / CU-UE12RKD / CU-UE18RKD service manuals if exist.