DOWNLOAD Panasonic CS-PA7CKE / CU-PA7CKE / CS-PC7CKE / CU-PC7CKE / CS-PA9CKE / CU-PA9CKE / CS-PC9CKE / CU-PC9CKE / CS-PA12CKE / CU-PA12CKE / CS-PC12CKE / CU-PC12CKE Service Manual ↓ Size: 2.4 MB | Pages: 85 in PDF or view online for FREE

Model
CS-PA7CKE CU-PA7CKE CS-PC7CKE CU-PC7CKE CS-PA9CKE CU-PA9CKE CS-PC9CKE CU-PC9CKE CS-PA12CKE CU-PA12CKE CS-PC12CKE CU-PC12CKE
Pages
85
Size
2.4 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / ROOM AIR CONDITIONER
File
cs-pa7cke-cu-pa7cke-cs-pc7cke-cu-pc7cke-cs-pa9cke-.pdf
Date

Panasonic CS-PA7CKE / CU-PA7CKE / CS-PC7CKE / CU-PC7CKE / CS-PA9CKE / CU-PA9CKE / CS-PC9CKE / CU-PC9CKE / CS-PA12CKE / CU-PA12CKE / CS-PC12CKE / CU-PC12CKE Service Manual ▷ View online

O(71 61>3= /321'= ,-)'1&'()% <)%'-)>
DL1->)3. ,-)'1&'()% <)%'-)>
<)70-1**)- ,-)'1&'()% <)%'-)>
P%'(H:1L1-*(%; ,-)'1&'()%
9HI3= K3>L1 <)%'-)>
C3-7 M))'(%; &)%'-)>
 • When turning on the unit by heating mode operation, indoor
fan will be activated when temperature of indoor heat
exchanger reaches 30°C.
 • Warm booting operation ends when temperature of indoor
heat exchanger reaches 34 °C.
 • During warm booting or within 3 minutes after the ending
the Ry-C will not turn off.
8Z5Z! \13'(%; X).1 D01-3'()% ]</H,P8<QR Y </H,PG<QR Y </H,P"+<QR^
When selecting heating mode operation, the unit will operate according to the setting by the remote control.
 • If the compressor stopped by switching off,turning off by remote control, or power off, it will not restart within 3 minutes.
 • When room temperature reaches the set temperature on the remote control, compressor stops and will not restart within 4
minutes.
 • 3 minutes after the compressor stopped, indoor fan will stop for 1 minute. Then indoor fan will resume operation with the speed
at "super low".
 • When temperature of indoor heat exchanger rises to 51°C, outdoor fan will stop when temperature of indoor heat exchanger
falls to 49°C, outdoor fan will restart.
 • When temperature of indoor heat exchanger rises to 65°C or above, compressor stops, and will restart 4 minutes later.
 • Same as the denotation in Cooling Operation.(P.25)
 • If the compressor has been running for 5 minutes, but the difference of temperature between intake air and indoor heat
exchanger is continuously lower than 5°C for 2 minutes, compressor will stop and resume operation in 4 minutes.
 • During heating mode operation, 4-way valve is at "open" mode.
 • During heating mode operation, if the unit turned off , the 4-way valve will remain at "open" mode for 5 minutes.
29
</H,P8<QR Y <SH,P8<QR Y </H,<8<QR Y <SH,<8<QR
P$')73'(& #3% 7).1 )01-3'()%
O(71 ;-30N 2)- N13'(%; 7).1 )01-3'()%
When selecting automatic fan mode by remote control during heating mode operation, the fan will operate at different speed
under different conditions according to the temperature of indoor heat exchanger.
30
</H,P8<QR Y <SH,P8<QR Y </H,<8<QR Y <SH,<8<QR
61(&1 <)%'-)>
Deice operation is to protect the outdoor unit from freezing.
 • Normal Deice Operation
Deicing starts 30 minutes after heating mode operation or 60 minutes after the latest deicing operation.If temperature of
outdoor piping,tested by TRS,falls to -3°C (TRS OFF) or below for continuously 50 seconds,deicing operation starts.
 • Overload Deicing Operation
During heating operation, if the accumulative stopping time of outdoor fan reaches 60 minutes, deicing operation will start
1 minute after compressor starts.
 • Deicing operation ends under conditions below
 1. After 12 minutes.
 2. Temperature of outdoor unit rises to 4°C.
 3. Because of time delay (Td),deicing operation will not end immediately.
 • Once deicing starts, it will not end within 60 seconds.
 • When deicing operation ends, compressor will stop for 30 seconds,and 4-way valve remains at cooling mode operation for
10 seconds.
31
</H,P8<QR Y <SH,P8<QR Y </H,<8<QR Y <SH,<8<QR
O(71 W-30N 2)- V)-73> 61(&(%; D01-3'()%
O(71 W-30N 2)- DL1->)3. 61(&(%;
32
</H,P8<QR Y <SH,P8<QR Y </H,<8<QR Y <SH,<8<QR
Page of 85
Display

Click on the first or last page to see other CS-PA7CKE / CU-PA7CKE / CS-PC7CKE / CU-PC7CKE / CS-PA9CKE / CU-PA9CKE / CS-PC9CKE / CU-PC9CKE / CS-PA12CKE / CU-PA12CKE / CS-PC12CKE / CU-PC12CKE service manuals if exist.