DOWNLOAD Panasonic CS-MP9DD4H5 / CS-MP14DD4H5 / CS-MP18DD4H5 / CS-MP18DD3H5 / CS-MP24DD3H5 / CS-MP24DD2H5 / CS-MP18DB4H5 / CS-MP24DB4H5 Service Manual ↓ Size: 4.45 MB | Pages: 127 in PDF or view online for FREE

Model
CS-MP9DD4H5 CS-MP14DD4H5 CS-MP18DD4H5 CS-MP18DD3H5 CS-MP24DD3H5 CS-MP24DD2H5 CS-MP18DB4H5 CS-MP24DB4H5
Pages
127
Size
4.45 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-mp9dd4h5-cs-mp14dd4h5-cs-mp18dd4h5-cs-mp18dd3h5.pdf
Date

Panasonic CS-MP9DD4H5 / CS-MP14DD4H5 / CS-MP18DD4H5 / CS-MP18DD3H5 / CS-MP24DD3H5 / CS-MP24DD2H5 / CS-MP18DB4H5 / CS-MP24DB4H5 Service Manual ▷ View online

2) Combination Number Reference For Indoor Unit 6HP
6HP Combination Number Reference (heating)
N0.
Units can be
connected
Quantity of indoor unit
Total rated
heating capacity of
indoor unit (KW)
Heating capacity
(KW)
Consumed power
(KW)
53
CU-MP28DBH5/CU-MP50DBH5
N0.
Units can be
connected
Quantity of indoor unit
Total rated
cooling capacity of
indoor unit (KW)
Cooling capacity
(KW)
Consumed power
(KW)
54
CU-MP28DBH5/CU-MP50DBH5
N0.
Units can be
connected
Quantity of indoor unit (B)
Total rated
cooling capacity of
indoor unit (KW)
Cooling capacity
(KW)
Consumed power
(KW)
55
CU-MP28DBH5/CU-MP50DBH5
Refrigerant
Distributor
Height
dif
ference
Pipe
length
Between
indoor
and
outdoor
units
Between
indoor
unites
T
o
tal
length
T
otal
length
of
main
pipe
T
otal
length
of
branch
pipes
Length
of
each
branch
pipe
Distance
between
the
outdoor
unit
and
the
furthermost
indoor
unit
Distance
between
the
first
branch
and
the
furthermost
indoor
unit
Longest
distance
Longest
distance
T
otal
length=T
otal
length
of
main
pipes
+
T
otal
length
of
branch
pipes
T
otal
length
of
main
pipes
=
M
ain
pip
e1+M
a
in
pipe
2
+
M
ain
pipe
3
+
M
ain
pipe
4
T
otal
length
of
branch
pipes
=
B
ranch
pipe1
+
B
ranch
pipe2
+
Branch
pipe3
+
B
ranch
pipe4
+
B
ranch
pipe5
Main
pipe
1
Main
pipe
2
Main
pipe
3
Main
pipe
4
First
branch
Second
branch
Third
branch
Branch
pipe1
Branch
pipe2
Branch
pipe3
Branch
pipe4
Branch
pipe5
Outdoor
unit
Indoor
unit
Indoor
unit
Indoor
unit
Indoor
unit
Indoor
unit
T
otal
length
of
branch
pipes
=
T
otal
length
of
main
pipes
+
T
otal
length
of
branch
pipes
The
furthermost
indoor
unit
56
8.4. Pipe Length Calculation and Rate of Change In Capacity
1) Pipe Length Calculation
CU-MP28DBH5/CU-MP50DBH5
Page of 127
Display