CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
10.4. Drain Pump Control
Basic operation
    
·
    
The drain pump starts 50 seconds after the indoor unit starts or the thermostat comes on (i.e., 10 seconds after the fan
motor starts).
The drain pump stops 30 seconds after the indoor unit stops or the thermostat turns off.
    
·
    
The drain pump repeats a cycle of on for 30 seconds then off for between 50 and 90 seconds as long as the unit is
operating. Operation while the unit is off is determined by the difference between the temperature setting and the room
temperature.
Float switch operation
    
·
    
When the float switch turns on for 10 seconds continuously, the thermostat of the indoor unit turns off and the drain pump
operates continuously.
    
·
    
When the float switch stays on for 150 seconds continuously, the drain pump and indoor unit stop and the timer lamp
flashes indicating an H21 error.
22
CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
10.5. Auto Restart Control
    
·
    
if there is a power failure, operation will automatically be restarted when the power is resumed. It will start with the previous
operation mode and airflow direction. (Time Delay Safety Control is valid)
 1. Control start conditions
<1> The 24-hour timer must not be set.
<2> The sleep timer must not be set.
Auto restart control is not available when timer or sleep mode is set.
 2. Description of control
<1> In the case of manual operation, the operation mode, temperature setting, fan speed and airflow direction before the power
is turned off are restored.
<2> In the case of automatic operation, after the power is restored operation starts with the determination of the mode.
<3> While the air conditioner odour clear timer has been set, the setting is cancelled, and operation is transferred to the mode
before the power is turned off.
<4> While the air conditioner odour clear operation (with timer / without timer setting) are being performed, both of these
operations are completed, and operation is transferred to the operation mode prior to these operations.
Example: When the power is turned off during an outdoor unit cooling operation
23
CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
10.6. Other Indoor Unit Operation Functions
10.6.1. Auto button
Proceed with operation when the air conditioner is stopped.
(When the auto button is pressed during operation, the air conditioner is stopped.)
 1. Emergency operation
Press the auto button and release it within 5 seconds to perform emergency operation.
Under normal condition (failure is not occurred) automatic operation is performed. In the event of a failure that still enables
operation to be performed, emergency operation is performed.
 2. Forced cooling operation
Keep pressing the auto button until one beep sounds to perform the automatic cooling operation.
The air conditioner does not operate for 2 minutes if the room temperature is low (intake temperature below 16 °C) so
just wait. The forced operation is performed after the 2 minutes have elapsed.
 3. Forced heating operation
First press the auto button until one beep sounds, and then set it to OFF.Now press the auto button until two beeps sound to
perform the automatic heating operation.
 4. Select Remote Control Transmission Code
    
·
    
There are 4 types of remote control transmission code could be selected and stored in EEPROM of indoor unit. The indoor
unit will only operate when received signal with same transmission code from remote control. This could prevent signal
interference when there are 2 more indoor unit installed nearby together.
    
·
    
To change remote control transmission code, short or open jumpers at the remote control printed circuit board.
24