DOWNLOAD Panasonic CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E Service Manual ↓ Size: 9.44 MB | Pages: 46 in PDF or view online for FREE

Model
CS-ME7EB1E CS-ME10EB1E CS-ME12EB1E CS-ME14EB1E
Pages
46
Size
9.44 MB
Type
PDF
Document
Simplified Service Manual
Brand
Device
Air Conditioner / MULTI AIR CONDITIONER
File
cs-me7eb1e-cs-me10eb1e-cs-me12eb1e-cs-me14eb1e.pdf
Date

Panasonic CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E Simplified Service Manual ▷ View online

17
CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
10 Operation Details (Functions & Protection)
10.1. Simultaneous Operation Control
 1. 
Operation modes which can be selected using the remote
control unit: Automatic, Cooling, Soft Dry, Heating, Fan operation
 2. 
Types of operations modes which can be performed
simultaneously
·
Cooling operation and cooling, Dry or fan operation
·
Heating operation and heating operation
 3. 
Types of operation modes which cannot be performed
simultaneously
·
While a cooling operation is in progress, a heating operation
cannot be performed by an indoor unit in another room.
In the room where the operation button for cooling was pressed
first, the operation is continued. In the room where the operation
button for heating was pressed afterward, the operation lamp of
the indoor unit blinks, where the attempt is made to establish the
heating operation. Its fan is stopped, and the air does not
discharged.
·
While a heating operation is in progress, a cooling operation
cannot be performed by an indoor unit in another room.
In the room where the operation button for heating was pressed
first, operation is continued. In the room where the operation
button for cooling was pressed afterward, the operation lamp of
the indoor unit blinks, where the attempt is made to establish the
cooling operation. Its fan is stopped, and the air does not
discharged.
 4. 
Operation mode priority control
·
The operation mode designated first by the indoor unit has
priority.
·
If the priority indoor unit stops operation or initiates the fan
operation, the priority is transferred to other indoor units.
“Waiting” denotes the standby status in which the operation
lamp LED blinks (ON for 2.5 sec. and OFF for 0.5 sec.), and
the fan is stopped.
* In the fan mode, priority is transferred to a non-priority unit.
Note
C: Cooling operation mode
D: Soft Dry operation mode
H: Heating operation mode
F: Fan operation mode
18
CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
mode.
10.2. Airflow Direction Control
The following shows how louver operation changes depending on the direction set with the AIR SWING button and other operating
conditions.
Cooling and Dry
Heating
·
The louver stops at the CLOSE position when the power switch or breaker is ON.
·
The louver stops at their current position when the power switch or breaker is OFF.
·
Move the horizontal airflow direction control louver manually.
19
CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
10.3. Indoor Fan Control
·
The following shows how fan speed changes depending on the setting made with the FAN SPEED button and other operating
conditions.
·
Actual fan speed may differ from that you set with remote control.
20
CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
Page of 46
Display

Click on the first or last page to see other CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E service manuals if exist.