DOWNLOAD Panasonic CS-MC90KA / CU-MC180KA / CS-MC90KA / CU-3MC200KA / CS-MC120KA / CU-MC240KA Service Manual ↓ Size: 3.39 MB | Pages: 94 in PDF or view online for FREE

Model
CS-MC90KA CU-MC180KA CS-MC90KA CU-3MC200KA CS-MC120KA CU-MC240KA
Pages
94
Size
3.39 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / SPLIT TYPE
File
cs-mc90ka-cu-mc180ka-cs-mc90ka-cu-3mc200ka-cs-mc12.pdf
Date

Panasonic CS-MC90KA / CU-MC180KA / CS-MC90KA / CU-3MC200KA / CS-MC120KA / CU-MC240KA Service Manual ▷ View online

MAC9902014C3
CS-MC90KA
– 72 –
Operating Instruction
1
2
3
4
5
m n
n o
2°C lower than
standard
standard
2°C higher than
standard
n
Press to select operation mode.
The display changes in the order
                                                
AUTO  COOL  DRY  FAN
each time the button is pressed.
Press to start the operation.
Operation indication lamp (RED) will light up.
Press once more, to stop the operation.
Press to select airflow volume.
The display changes in the order.
                        
AUTO FAN
Automatic
Low
Medium
High
Press to select room temperature.
Cooling, Soft Dry, Air Circulation – Select temperature as desired.
(16°C ~ 30°C)
Automatic.
Press           continuously.
The vertical airflow direction louver will move up and down. Release the button
when the louver is at the desired position.
Press          .
The vertical airflow direction louver will swing up and down automatically. To
stop the automatic airflow direction operation, press          button.
h j k
h j k
h j k
l
lll
lllll
34°
58°
Cooling
Soft Dry
FAN SPEED
MODE
MANUAL
OFF/ON 
I
i
TEMP.
MANUAL
SWING
FAN – Air Circulation Operation.
When the room temperature reaches the setting
temperature, operation commences at Low air-
flow volume. It stops when the room temperature
drops to 2°C below the setting temperature (It is
useful when using a heater).
Automatic Airflow Volume.
The speed of the indoor fan is adjusted automati-
cally to “High” if the compressor is in operation,
and to “Medium” speed if the compressor is
stopped.
Range of louver adjustment.
MANUAL
SWING
Air
Circulation
Untitled-5
6/19/00, 10:42 AM
72
– 73 –
MAC9902014C3
CS-MC90KA
Operating Instruction
<Note>
Regarding remote control.
If the current time is not set correctly, correct
Timer setting will not be possible.
When the Timer is set, the current time display
will vanish.
[RESET] points will clear the memory once they
are shorted.
[B 
 A] switch is used when 2 air
conditioners units have been installed in one
room. Please consult your dealer.
OPEN
If there is a power failure.
OFF-TIMER
SET
To reset the Timer.
(Example) If the OFF Timer has been set.
Even if there is a power failure, the setting
time is stored in memory because the remote
control is a battery type.
q
OFF/ON
SLEEP
PM
OFF-TIMER
TIME
ON-TIMER
SET
CANCEL
11
:
30
[B 
 A] switch
[RESET] points
Setting the Timer
Untitled-5
6/19/00, 10:42 AM
73
MAC9902014C3
CS-MC90KA
– 74 –
Operating Instruction
Set hours and minutes
To set the Timer.
OFF Timer
Set hours and minutes
The “OFF-TIMER” will blink.
ON Timer
Set hours and minutes
The “ON-TIMER” will blink.
To cancel the Timer.
OFF Timer
To change the Timer setting time.
(Example) To change the ON Timer.
Setting from 7:20AM to 6:20AM
Set hours and minutes
The Timer indication lamp at main unit
will light up. LED colour: Orange.
.... to increase 10 min-
utes each step.
.... to decrease 10 min-
utes each step.
.... to decrease 10 min-
utes each step.
OFF-TIMER
CANCEL
The Timer indication lamp at main unit
will light up. LED colour: Orange.
The Timer indication lamp at
main unit will go off.
To cancel the ON Timer, follow
the same procedure.
Setting the OFF Timer.
Setting the ON Timer.
   q
   q
OFF-TIMER
0N-TIMER
0N-TIMER
SET
SET
SET
TIME
TIME
TIME
TIME
If the air conditioner is set before you go out,
the room temperature will be close to your
desired temperature when you return.
This is useful for saving electricity costs in-
curred by forgetting to turn off the air condi-
tioner.
.... to advance the time.
.... to reverse the time.
.... to  increase 10 min-
utes each step.
.... to decrease 10 min-
utes each step.
Timer
The ON Timer and OFF Timer can only be set
once during a day.
The operation will start before the actual setting
time with ON Timer setting.
This is to allow time to attain your desired set
temperature.
Automatic, Cooling and Soft Dry :
15 minutes before.
To set the current time.
Untitled-5
6/19/00, 10:42 AM
74
– 75 –
MAC9902014C3
CS-MC90KA
Operating Instruction
This is to gain a comfortable room temperature while sleeping.
Sleep Mode Operation.
When the room temperature reaches
the setting temperature, the airflow
volume will automatically change to
low.
Sleep Mode Operation time is 8
hours.
When using together with the Timer,
the Timer has priority.
<Information>
Cooling or Soft Dry Operation for Sleep Mode movement will start to avoid overcooling.
To set Sleep Mode.
Press
(The sleep indication lamp on the
main unit will light up.)
To cancel Sleep Mode.
Press once more
(The sleep indication lamp on the
main unit will switch off.)
Approx. 0.5°C increase
Approx. 0.5°C increase
1 hour
Sleep Operation starts.
0 – 1 hour
After approx. 8
hours stops
automatically.
TEMP.
TIME
SLEEP
SLEEP
Sleep mode
SETTING
TEMPERATURE
OFF/ON
SLEEP
PM
MODE
TEMP.
FAN SPEED
MANUAL
SWING
AIR SWING
AUTO
°C
11
:
30
c
27
h j k
Convenient Operation
Untitled-5
6/19/00, 10:42 AM
75
Page of 94
Display

Click on the first or last page to see other CS-MC90KA / CU-MC180KA / CS-MC90KA / CU-3MC200KA / CS-MC120KA / CU-MC240KA service manuals if exist.