Panasonic CS-F18DTE5 / CU-L34DBE5 Service Manual ▷ View online

13.7. Safety device
13.7.1. Indoor unit
Indoor unit
Heat pump model
CS-F18DTE5
Cooling only model
For fan motor protection
Internal
OFF
°C
135
protector
ON
°C
87
For condensation temperature
protection control
OFF
°C
58
Heat exchanger
RESET
°C
54
thermistor
For P.C.B current protection
Current fuse
CUT
A
3.15
Note : Protection controlled by P.C.B installed of FM inside.
13.7.2. Outdoor unit
Outdoor unit
Heat pump
model
50Hz
CU-L34DBE5
For refrigerant cycle
High pressure
OFF
MPa
4.2
switch
ON
MPa
3.3
For compressor over current
protection for cooling mode
CT1 frequency down
OFF
A
17
RESET
A
13
CT2 compressor stop
OFF
A
22
For compressor over current
protection for heating mode
CT1 frequency down
OFF
A
23
RESET
A
13
CT2 compressor stop
OFF
A
28
Discharge temp protection
Discharge temperature
Compressor
°C
Td
110°C
→ Comp OFF
thermistor (Td)
OFF
Td
110 °C x 3 times within 1 hour
→ display error cord
Liquid compress protection
Crankcase heater
-
W
33
For fan motor protection
Internal
OFF
°C
135
protector (49F)
ON
°C
87
For condensation temperature
protection control
OFF
°C
58
Heat exchanger
RESET
°C
54
thermistor (Th)
For control protection
Fuse
CUT
A
6.3
1MPa = 10.2kgf/cm
2
13.8. Operating characteristics
Main Power
Compressor Motor
Indoor Unit
Outdoor Unit
Model
Source
Fan Motor
Fan Motor
Voltage
Frequency
S.C.
R.C. (A)
IPT (kW)
R.C.
IPT
R.C.
IPT
(V)
(Hz)
(A)
COOL / HEAT
COOL / HEAT
(A)
(kW)
(A)
(kW)
HEAT
CS-F18DTE5 x2
220
50
9.9
12.75 / 14.15
2.74 / 3.02
0.35 x2
0.07 x2
0.55
0.12
PUMP
CU-L34DBE5
230
50
9.5
12.35 / 13.65
2.74 / 3.02
0.35 x2
0.07 x2
0.55
0.12
MODEL
240
50
9.2
11.85 / 13.15
2.74 / 3.02
0.35 x2
0.07 x2
0.55
0.12
Legend :
S.C. : Starting Current
R.C. : Running Current
IPT : Power Consumption
105
CS-F18DTE5 CU-L34DBE5 /
14 Replacement Parts
14.1. Indoor unit
106
CS-F18DTE5 CU-L34DBE5 /
107
CS-F18DTE5 CU-L34DBE5 /
108
CS-F18DTE5 CU-L34DBE5 /
Page of 127
Display