Panasonic CS-F18DTE5 / CU-L34DBE5 Service Manual ▷ View online
13.5.2. Heating performance
Model name
Max heating capacity
Max capacity (kw)
Max power consumption (kw)
CS-F18DTE5 / CU-L34DBE5
13.5
4.2
1. Heating capacity when the unit is frosted over or while being defrosted will vary depending on outdoor temperature and the
frosting.
2. Heating capacity must be compensated because it does not take into account the capacity drop incurred when the unit is
frosted over and while it is being defrosted.
3. Therefore, to obtain the integral heating capacity in consideration overfrosting and defrost operations.
4. Heating capacity must be multiplied by the compensation coefficient below.
101
CS-F18DTE5 CU-L34DBE5 /
13.5.2.1. CS-F18DTE5 x2, CU-L34DBE5
Heating capacity curve
Outdoor intake air ambient temperature (D.B./ °C)
-20°C -15°C -10°C
-5°C
0°C
2°C
5°C
7°C
10°C
15°C
>15°C
Heating
capacity
0.93
0.93
0.93
0.92
0.84
0.88
0.96
1
1
1
1
compensation
coefficient
102
CS-F18DTE5 CU-L34DBE5 /
Heating power consumption curve
Outdoor intake air ambient temperature (D.B./ °C)
-20°C -15°C -10°C
-5°C
0°C
5°C
7°C
10°C
15°C
>15°C
Heating
capacity
0.93
0.93
0.93
0.92
0.86
0.97
1
1
1
1
compensation
coefficient
103
CS-F18DTE5 CU-L34DBE5 /
13.6. Fan performance
13.6.1. CS-F18DTE5
104
CS-F18DTE5 CU-L34DBE5 /
Click on the first or last page to see other CS-F18DTE5 / CU-L34DBE5 service manuals if exist.