DOWNLOAD Panasonic CS-E10JD3EA / U-E10HBEA / CS-E15JD3EA / CU-E15HBEA / CS-E18JD3EA / CU-E18HBEA Service Manual ↓ Size: 4.37 MB | Pages: 105 in PDF or view online for FREE

Model
CS-E10JD3EA U-E10HBEA CS-E15JD3EA CU-E15HBEA CS-E18JD3EA CU-E18HBEA
Pages
105
Size
4.37 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-e10jd3ea-u-e10hbea-cs-e15jd3ea-cu-e15hbea-cs-e1.pdf
Date

Panasonic CS-E10JD3EA / U-E10HBEA / CS-E15JD3EA / CU-E15HBEA / CS-E18JD3EA / CU-E18HBEA Service Manual ▷ View online

77
15.5.18. F93 (Compressor Rotation Failure)
Malfunction Decision Conditions
A compressor rotation failure is detected by checking the compressor running condition through the position detection circuit.
Malfunction Caused
• Compressor terminal disconnect.
• Outdoor PCB malfunction.
• Compressor malfunction.
Troubleshooting
78
15.5.19. F95 (Cooling High Pressure Abnormality)
Malfunction Decision Conditions
During operation of cooling, when outdoor unit heat exchanger high temperature data (61
°C) is detected by the outdoor pipe
temperature sensor.
Malfunction Caused
• Air short circuit at outdoor unit.
• Dust accumulation on the outdoor unit heat exchanger.
• 2/3 way valve closed.
• Faulty outdoor unit fan motor.
• Excessive refrigerant.
• Clogged expansion valve or strainer.
• Faulty outdoor pipe temperature sensor.
• Faulty outdoor unit PCB.
Troubleshooting
79
15.5.20. F96 (IPM Overheating)
Malfunction Decision Conditions
During operating of cooling and heating, when IPM temperature data (100
°C) is detected by the IPM temperature sensor.
Multi Models Only
• Compressor Overheating: During operation of cooling and heating, when the compressor OL is activated.
• Heat Sink Overheating: During operation of cooling and heating, when heat sink temperature data (90°C) is detected by the heat
sink temperature sensor.
Malfunction Caused
• IPM overheats due to short circuit of hot discharge air flow.
• IPM overheats due to defective of outdoor fan motor.
• IPM overheats due to defective of internal circuitry of IPM.
• IPM overheats due to defective IPM temperature sensor.
Multi Models Only
• Compressor OL connector poor contact.
• Compressor OL faulty.
Troubleshooting
80
15.5.21. F97 (Compressor Overheating)
Malfunction Decision Conditions
During operation of cooling and heating, when compressor tank temperature data (112°C) is detected by the compressor
tank temperature sensor.
Malfunction Caused
• Refrigerant shortage (refrigerant leakage).
• 2/3 way valve closed.
• Detection error due to faulty compressor tank temperature sensor.
Troubleshooting
Page of 105
Display

Click on the first or last page to see other CS-E10JD3EA / U-E10HBEA / CS-E15JD3EA / CU-E15HBEA / CS-E18JD3EA / CU-E18HBEA service manuals if exist.