DOWNLOAD Panasonic CS-E10JD3EA / U-E10HBEA / CS-E15JD3EA / CU-E15HBEA / CS-E18JD3EA / CU-E18HBEA Service Manual ↓ Size: 4.37 MB | Pages: 105 in PDF or view online for FREE

Model
CS-E10JD3EA U-E10HBEA CS-E15JD3EA CU-E15HBEA CS-E18JD3EA CU-E18HBEA
Pages
105
Size
4.37 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-e10jd3ea-u-e10hbea-cs-e15jd3ea-cu-e15hbea-cs-e1.pdf
Date

Panasonic CS-E10JD3EA / U-E10HBEA / CS-E15JD3EA / CU-E15HBEA / CS-E18JD3EA / CU-E18HBEA Service Manual ▷ View online

13
1. Cooling capacities are based on indoor temperature of 27
°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35
°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20
°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry
Bulb (44.6
°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Specifications are subjected to change without prior notice for further improvement.
 MODEL
INDOOR
CS-E18JD3EA
OUTDOOR
CU-E18HBEA
Indoor Heat
Exchanger
Fin Material
Aluminium (Pre Coat)
Fin Type
Split Fin
Row 
× Stage × FPI
× 12 × 18
Size (W 
× H × L)
mm
620 
× 252 × 38.1
Outdoor Heat
Exchanger
Fin Material
Aluminium
Fin Type
Corrugated Fin
Row 
× Stage × FPI
× 34 × 17
Size (W 
× H × L)
mm
36.4
× 714 × 823.2
                     851.9
Power Supply
Outdoor Power Supply
Power Supply Cord
A
Nil
Thermostat
Electronic Control
Protection Device
Electronic Control
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum
32
23
Minimum
16
11
Heating
Maximum
30
Minimum
16
Outdoor Operation Range
Cooling
Maximum
43
26
Minimum
-10
Heating
Maximum
24
18
Minimum
-10
14
3 Features
• Inverter Technology
- Wider output power range
- Energy saving
- Quick Cooling
- Quick  Heating
- More precise temperature control
• Environment Protection
- Non-ozone depletion substances refrigerant (R410A)
• Long Installation Piping
Long piping up to 20 meter (E10/15HBEA), 30 meter (E18HBEA)
• Easy to use remote control
• Quality Improvement
Random auto restart after power failure for safety restart operation
- Gas leakage protection
- Prevent compressor reverse cycle
- Inner protector to protect compressor
- Noise prevention during soft dry operation
• Operation Improvement
Quiet mode to reduce the indoor unit operating sound
- Powerful mode to reach the desired room temperature quickly
- 24-hour timer setting
• Serviceability Improvement
Breakdown Self Diagnosis function
15
4 Location of Controls and Components
4.1.
Indoor Unit
4.2.
Outdoor Unit
4.3.
Remote Control
16
5 Dimensions
5.1.
Indoor Unit & Remote Control
5.1.1.
CS-E10JD3EA  CS-E15JD3EA
Page of 105
Display

Click on the first or last page to see other CS-E10JD3EA / U-E10HBEA / CS-E15JD3EA / CU-E15HBEA / CS-E18JD3EA / CU-E18HBEA service manuals if exist.