DOWNLOAD Panasonic CS-C7HKD / CS-C9HKD / CS-C12HKD / CU-C7HKD / CU-C9HKD / CU-C12HKD Service Manual ↓ Size: 5.24 MB | Pages: 64 in PDF or view online for FREE

Model
CS-C7HKD CS-C9HKD CS-C12HKD CU-C7HKD CU-C9HKD CU-C12HKD
Pages
64
Size
5.24 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-c7hkd-cs-c9hkd-cs-c12hkd-cu-c7hkd-cu-c9hkd-cu-c.pdf
Date

Panasonic CS-C7HKD / CS-C9HKD / CS-C12HKD / CU-C7HKD / CU-C9HKD / CU-C12HKD Service Manual ▷ View online

9
2.3.
CS-C12HKD CU-C12HKD
1. Cooling capacities are based on indoor temperature of 27
°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35
°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20
°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6
°C W.B. (42.8°F W.B.)
Item
Unit
Indoor unit
Outdoor unit
Performance Test Condition 
JIS
Capacity
kW
3.52 - 3.54
BTU/h
12000 - 12100
kcal/h
3030 - 3050
EER
W/W
3.17 - 3.08
BTU/hW
10.8 - 10.5
Noise Level
dB (A)
High: 39 Low: 29
High: 48 - 49
Power level dB
High: 52
High: 63 - 64
Moisture Removal
l/h
2.1
(pt/h)
4.4
Air Volume
Lo
m
3
/m (ft
3
/m)
6.9 (243) - 6.9 (243)
Me
m
3
/m (ft
3
/m)
8.1 (286) - 8.1 (286)
Hi
m
3
/m (ft
3
/m)
9.7 (343) - 9.7 (343)
30.9 (1090) - 32.3 (1140)
SHi
m
3
/m (ft
3
/m)
10.1 (356) - 10.1 (356)
Refrigerant Control Device
Capillary Tube
Refrigerant Oil (Charged)
cm
3
ATMOS M60 or
SUNISO 4GDID (410cm
3
)
Refrigerant (Charged) R22
kg (oz)
0.49 (17.3)
Dimension
Height
mm (inch)
280 (11 - 1/32)
510 (20 - 3/32)
Width
mm (inch)
799 (31 - 15/32)
650 (25 - 19/32)
Depth
mm (inch)
183 (7 - 7/32)
230 (9 - 1/16)
Net Weight
kg (lbs)
9 (20)
27 (60)
Pipe Diameter
Gas
mm (inch)
12.70 (1/2”)
Liquid
mm (inch)
6.35 (1/4”)
Height Difference
m (ft)
5 (16.4)
Pipe Length Range
m (ft)
3 (9.8) ~ 15 (49.2)
Additional Gas Amount
g/m (oz/ft)
10 (0.1)
Refrigeration Charge Less
m (ft)
7.5 (24.6)
Drain Hose
Inner diameter
mm
16
Length
mm
650
Compressor
Type
Rotary (1 cylinder)
rolling piston type
Motor Type
Induction (2-poles)
Rated Output
W
950
Fan
Type
Cross-flow Fan
Propeller Fan
Material
ASG20K1
PP Resin
Motor Type
Induction (4-poles)
Induction (6-poles)
Input power
W
55.0 - 66.0
59.4 - 67.3
Output power
W
15
31
Fan Speed
Lo (Cool)
rpm
900 - 900
Me (Cool)
rpm
1060 - 1060
Hi (Cool)
rpm
1270 - 1270
815 - 850
SHi (Cool)
rpm
1320 - 1320
Heat Exchanger
Fin material
Aluminium (Pre Coat)
Aluminium (Blue Coat)
Fin Type
Slit Fin
Slit Fin
Row 
× Stage × FPI
× 15 × 19
× 22 × 17
Size (W 
× H × L)
mm (inch)
610 
× 315 × 25.4
25.4 
× 483 × 582
                      562
Air Filter Type
Material
Polypropelene
Style
One-touch
10
Note:
• Specification are subjected to change without prior notice for further improvement.
 Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
Single
V 220
240
Hz
50
50
Input power
kW
1.11
1.15
Starting Current
A
26
26
Running Current
Cooling
A
5.3
5.2
Maximum Current
A
7.0
7.0
Power Factor
Cooling
%
95
92
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core
3 (1.5mm)
Length
m (ft)
2 (6)
Thermostat
Protection Device
Inner Protector
11
3 Features
• E-ion Air Purifying System with Patrol Sensor
- Active e-ions are released to catch dust particles and bring them back the large positively charged filter
- Patrol Sensor color changes to indicate the dirt level in the air
• Long Installation Piping
CS/CU-C7HK, CS/CU-C9HK, long piping up to 10 meters
CS/CU-C12HK, long piping up to 15 meters
• Easy to use remote control
• Quality Improvement
Random auto restart after power failure for safety restart operation
- Gas leakage protection
- Prevent compressor reverse cycle
- Inner protector to protect compressor
- Noise prevention during soft dry operation
Blue Coated Condenser for high resistance to corrosion
• Operation Improvement
Quiet mode to provide quiet operation
- Powerful mode to reach the desired room temperature quickly
- 24-hour timer setting
12
4 Location of Controls and Components
4.1.
Product Overview
4.1.1.
Indoor Unit
4.1.2.
Outdoor Unit
4.1.3.
Remote Control
Page of 64
Display

Click on the first or last page to see other CS-C7HKD / CS-C9HKD / CS-C12HKD / CU-C7HKD / CU-C9HKD / CU-C12HKD service manuals if exist.