Panasonic CS-C18CKE / CU-C18CKE / CS-C24CKE / CU-C24CKE Service Manual ▷ View online
•
•
•
• Manual Fan Speed:-
−
−
−
− RPM control during Lo cool
−
−
−
− RPM control during Hi & Me cool
•
•
•
• Auto Fan Speed:-
•
•
•
• Quiet Mode Operation will stop if:-
−
−
−
− Quiet mode button is pressed again.
−
−
−
− Stopped by ON/OFF switch.
−
−
−
− Timer OFF activates.
−
−
−
− Powerful mode button is pressed.
−
−
−
− When change mode to Air Circulation mode.
21
CS-C18CKE CU-C18CKE / CS-C24CKE CU-C24CKE
Time Delay Safety Control
Anti-Freezing Control
Compressor Reverse Rotation Protection Control
Anti-Dew Formation Control
Automatic Fan Speed Mode
8.3. Soft Dry Mode Operation
•
•
•
• The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and
then Soft Dry operation will start.
•
•
•
• During Soft Dry operation, the Indoor Fan will operate at Lo- speed.
•
•
•
• Once room temperature reaches below Soft Dry OFF temperature. Indoor Fan, Compressor and Outdoor Fan stop for 6
minutes.
•
•
•
• Once the compressor stops, it will not start for 3 minutes during Cooling operation.
•
•
•
• Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor
stops.)
•
•
•
• Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting
is valid during compressor stops.)
•
•
•
• Same as Anti-Dew Formation Control for Cooling Mode operation.
When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.
•
•
•
• Fan speed off and on at Lo- speed.
•
•
•
• Deodorizing Control.
22
CS-C18CKE CU-C18CKE / CS-C24CKE CU-C24CKE
Soft Dry Operation Time Diagram
Quiet Operation Control
•
•
•
• Same as Quiet Operation Control for Cooling Mode operation.
23
CS-C18CKE CU-C18CKE / CS-C24CKE CU-C24CKE
Standard for Determining Operation Mode
8.4. Air Circulation Mode Operation
•
•
•
• Fan operation only. Indoor fan speed selection by remote control and setting refer to Indoor Fan Speed Control.
−
−
−
− Manual Fan Speed
Follow remote control setting
−
−
−
− Auto Fan Speed
8.5. Automatic Mode Operation
•
•
•
• Indoor fan operates at SLo fan speed for 20 seconds.
•
•
•
• After judging indoor air temperature, the operation mode is determined and operation continued at the mode determined.
•
•
•
• After the operation mode has been determined, the mode does not change. However, Soft Dry mode operation includes
Cooling mode operation.
•
•
•
• Room temperature adjustment.
The following are added to the setting temperature specified as above.
24
CS-C18CKE CU-C18CKE / CS-C24CKE CU-C24CKE
Click on the first or last page to see other CS-C18CKE / CU-C18CKE / CS-C24CKE / CU-C24CKE service manuals if exist.