DOWNLOAD Panasonic CS-A75KE / CS-A95KE / CS-A125KE / CU-A75KE / CU-A95KE / CU-A125KE Service Manual ↓ Size: 8.35 MB | Pages: 97 in PDF or view online for FREE

Model
CS-A75KE CS-A95KE CS-A125KE CU-A75KE CU-A95KE CU-A125KE
Pages
97
Size
8.35 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / SPLIT TYPE
File
cs-a75ke-cs-a95ke-cs-a125ke-cu-a75ke-cu-a95ke-cu-a.pdf
Date

Panasonic CS-A75KE / CS-A95KE / CS-A125KE / CU-A75KE / CU-A95KE / CU-A125KE Service Manual ▷ View online

  • 
Inspection points for the Indoor Electronic Controller
 1. The Electronic Controller, a signal Receiver and an
Indicator (Fig. 2) can be seen by the below steps:
  − 
Remove the 2 caps and 2 screws at the bottom of
the front grille. (Fig. 1)
  − 
Remove the front grille by releasing the 2 hooks at
the top of the front grille. (Fig. 1)
  − 
Remove the control board cover by releasing the 2
tabs at left, 1 tab on top and 2 more tabs at right side
of the control board cover. (Fig. 1)
 2. To remove the Electronic Controller, release the hook
that holding the electronic controller. (Fig. 2)
  • 
Indoor Fan Motor removal procedure:-
 1. Remove the control board by:-
  − 
Releasing CN-C (GRN) connector. (Fig. 2)
  − 
Releasing CN-FM (GRN) connector. (Fig. 2)
  − 
Releasing CN-STM connector. (Fig. 2)
  − 
Remove the earth wire screw. (Fig. 2)
  − 
Release the intake air sensor. (Fig. 2)
  − 
Release the piping sensor. (Fig. 2)
  − 
Unhook and release the terminal board. (Fig. 3)
  − 
Remove the right and left screws. (Fig. 3)
  − 
Then remove the control board by pressing down the
hook at the left and press up the right hook. (Fig. 3)
 2. Remove the Fan Motor by:-
  − 
Release the Fan motor leadwire by pressing the
hook at the center of the connector. (Fig. 4)
  − 
Then remove the particular piece that holding the
fan motor by pressing the tab. (Fig. 4)
  − 
Remove the discharge grille and then the drain
hose. (Fig. 4)
Fig. 1
Fig. 2
Fig. 3
Fig. 4
12 Servicing Information
73
CS-A75KE CU-A75KE / CS-A95KE CU-A95KE / CS-A125KE CU-A125KE
  − 
Finally remove the fan motor by removing the screw.
(Fig. 5)
  − 
REMINDER - To reinstall the fan motor, adjust the
connector of the fan motor as Fig. 5.
  • 
Cross Flow Fan Removal Procedure.
 1. Remove the control board and the fan motor by referring
to the “Indoor Fan Motor Removal Procedure”.
 2. Remove the evaporator screw. (Fig. 6)
 3. Press the particular piece to loosen the evaporator. (Fig.
7)
 4. Remove the bearing. (Fig. 7)
 5. Push up the evaporator and take out the cross-flow Fan.
(Fig. 7)
Fig. 5
Fig. 6
Fig. 7
74
S-A75KE CU-A75KE / CS-A95KE CU-A95KE / CS-A125KE CU-A125KE
  • 
Remote Control Reset
When the batteries are inserted for the first time, or the
batteries are replaced, all the indications will blink and the
remote control might not work.
If this happen, remove the back cover of the remote control
and you will find a resetting terminal, and by shorting it with
a minus screwdriver, it will return to normal.
  • 
Changing the wireless remote control transmission
code
When two indoor units are installed in the same room, in
order to prevent operating errors caused by using two
remote controls, add a jumper wire to the remote control
side (J-B) and a carbon resistor (1/4 W, 10 kW) to the
indoor printed circuit (RX-1) board, it is possible to select
from 2 types of transmission codes including one at time of
delivery condition (1).
75
CS-A75KE CU-A75KE / CS-A95KE CU-A95KE / CS-A125KE CU-A125KE
In order to diagnose malfunctions, make sure that there are no
electrical problems before inspecting the refrigeration cycle.
Such problems include insufficient insulation, problem with the
power source, malfunction of a compressor and a fan.
The normal outlet air temperature and pressure of the
refrigeration cycle depends on various conditions, the standard
values for them are shown in the table to the right.
13 Troubleshooting Guide
13.1. Refrigeration cycle system
76
S-A75KE CU-A75KE / CS-A95KE CU-A95KE / CS-A125KE CU-A125KE
Page of 97
Display

Click on the first or last page to see other CS-A75KE / CS-A95KE / CS-A125KE / CU-A75KE / CU-A95KE / CU-A125KE service manuals if exist.