DOWNLOAD Panasonic CS-A28JKD / CU-A28JKD Service Manual ↓ Size: 5.64 MB | Pages: 64 in PDF or view online for FREE

Model
CS-A28JKD CU-A28JKD
Pages
64
Size
5.64 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-a28jkd-cu-a28jkd.pdf
Date

Panasonic CS-A28JKD / CU-A28JKD Service Manual ▷ View online

5
2 Specifications
Model
Indoor
CS-A28JKD
Outdoor
CU-A28JKD
Performance Test Condition
NEW JIS
Power Supply
Phase, Hz
Single, 50
V
220
230
Cooling
Capacity
kW
8.00
8.00
BTU/h
27300
27300
kJ/h
28800
28800
Running Current
A
13.2
12.7
Input Power
W
2.86k
2.88k
EER
W/W
2.80
2.78
BTU/hW
9.55
9.48
Power Factor
%
98
99
Indoor Noise
dB-A (H/L)
49-49 / 44-44
Power Level dB
65 / 65
Outdoor Noise
dB-A (H/L)
55 / 55
Power Level dB
70 / 70
Heating
Capacity
kW
8.80
8.80
BTU/h
30000
30000
kJ/h
31680
31680
Running Current
A
13.1
12.6
Input Power
W
2.84k
2.86k
COP
W/W
3.10
3.08
BTU/hW
10.56
10.49
Power Factor
%
99
99
Indoor Noise
dB-A (H/L)
48-48 / 44-44
Power Level dB
64 / 64
Outdoor Noise
dB-A (H/L)
55 / 55
Power Level dB
71 / 71
Max Current (A) / Max Input Power (W)
16.4 / 3.45k
Starting Current (A)
40
Compressor
Type
Hermetic motor
Motor Type
Induction (2-poles)
Output Power
W
2.4k
Indoor
 Fan
Type
Cross-flow Fan
Material
ASG30K1
Motor Type
DC Motor
Input Power
W
94.8 - 94.8
Output Power
W
40
Speed
Lo
rpm
Cooling: 1250 - 1250
Heating: 1330 - 1330
Me
rpm
Cooling: 1380 - 1380
Heating: 1380 - 1380
Hi
rpm
Cooling: 1500 - 1500
Heating: 1540 - 1540
SHi
rpm
Cooling: 1540 - 540
Out
d
oor F
a
n
Type
Propeller Fan
Material
PP
Motor Type
Induction (6-poles)
Input Power
W
163.1
Output Power
W
80
Speed
Lo
rpm
490 - 520
Hi
rpm
855 - 870
Moisture Removal
L/h (Pt/h)
4.7 (9.9)
6
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) 
and outdoor air temperature of 35
qC Dry Bulb (95qF Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry 
Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Specifications are subjected to change without prior notice for further improvement.
Indoor Airflow
Lo
m
3
/min (ft
3
/m)
Cooling: 16.5 (583) - 16.5 (583)
Heating: 17.6 (622) - 17.6 (622)
Me
m
3
/min (ft
3
/m)
Cooling: 18.2 (643) - 18.2 (643)
Heating: 18.3 (646) - 18.3 (646)
Hi
m
3
/min (ft
3
/m)
Cooling: 19.8 (699) - 19.8 (699)
Heating: 20.4 (720) - 20.4 (720)
SHi
m
3
/min (ft
3
/m)
20.3 (718) - 20.3 (718)
Outdoor Airflow
Lo
m
3
/min (ft
3
/m)
30.1 (1060) - 32.0 (1130)
Hi
m
3
/min (ft
3
/m)
52.5 (1850) - 53.5 (1890)
Refrigeration Cycle
Control Device
Capillary Tube
Refrigerant Oil
cm
3
SUNISO 4GDID or ATMOS M60 or ATMOS  56M  (900)
Refrigerant Type
g (oz)
R22, 2130 (75.2)
Dimension
Height (I/D / O/D)
mm (inch)
290 (11-7/16) / 750 (29-17/32)
Width (I/D / O/D)
mm (inch)
1070 (42-5/32) / 875 (34-15/32)
Depth (I/D / O/D)
mm (inch)
235 (9-9/32) / 345 (13-19/32)
Weight
Net (I/D / O/D)
kg (lb)
12 (27) / 66 (146)
P
iping
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4”) / 15.88 (5/8”)
Standard length
m (ft)
5 (16.4)
Length range (min~max)
m (ft)
3~30 (9.8~98.4)
I/D & O/D Height different
m (ft)
20.0 (65.6)
Additional Gas Amount
g/m (oz/ft)
30 (0.3)
Length for Additional Gas
m (ft)
7.5 (24.6)
Drain Hose
Inner Diameter
mm
12
Length
mm
560
Indoor Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row 
u Stage u FPI
u 15 u 21
Size (W 
u H u L)
mm
810 
u 315 u 25.4
Outdoor Heat Exchanger
Fin Material
Aluminium (Blue Coat)
Fin Type
Corrugated Fin
Row 
u Stage u FPI
u 28 u 17
Size (W 
u H u L)
mm
810 
u 315 u 25.4
44 
u 711.2 u 802.4
836.4
Air Filter
Material
Polypropelene
Type
One-touch
Power Supply
Indoor Power Supply
Power Supply Cord
A
20
Thermostat
Protection Device
Inner Protector
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum
32
23
Minimum
16
11
Heating
Maximum
30
Minimum
16
Outdoor Operation Range
Cooling
Maximum
43
26
Minimum
16
11
Heating
Maximum
24
18
Minimum
-5
-6
7
3 Features
• E-ion Air Purifying System with Patrol Sensor
- Active e-ions are released to catch dust particles and bring them back the large positively charged filter.
- Patrol Sensor color changes to indicate the dirt level in the air.
• Long Installation Piping
- Long piping up to 30 meters.
• Easy to use remote control
• Quality Improvement
- Random auto restart after power failure for safety restart operation.
- Gas leakage protection.
- Prevent compressor reverse cycle.
- Inner protector to protect compressor.
- Noise prevention during soft dry operation.
- Blue coated condenser for high resistance to corrosion.
• Operation Improvement
- Quiet mode to reduce the indoor unit operating sound.
- Powerful mode to reach the desired room temperature quickly.
- 24-hour timer setting.
8
4 Location of Controls and Components
4.1.
Indoor Unit
4.2.
Outdoor Unit
4.3.
Remote Control
Page of 64
Display

Click on the first or last page to see other CS-A28JKD / CU-A28JKD service manuals if exist.