Panasonic CS-A28JKD / CU-A28JKD Service Manual ▷ View online
5
2 Specifications
Model
Indoor
CS-A28JKD
Outdoor
CU-A28JKD
Performance Test Condition
NEW JIS
Power Supply
Phase, Hz
Single, 50
V
220
230
Cooling
Capacity
kW
8.00
8.00
BTU/h
27300
27300
kJ/h
28800
28800
Running Current
A
13.2
12.7
Input Power
W
2.86k
2.88k
EER
W/W
2.80
2.78
BTU/hW
9.55
9.48
Power Factor
%
98
99
Indoor Noise
dB-A (H/L)
49-49 / 44-44
Power Level dB
65 / 65
Outdoor Noise
dB-A (H/L)
55 / 55
Power Level dB
70 / 70
Heating
Capacity
kW
8.80
8.80
BTU/h
30000
30000
kJ/h
31680
31680
Running Current
A
13.1
12.6
Input Power
W
2.84k
2.86k
COP
W/W
3.10
3.08
BTU/hW
10.56
10.49
Power Factor
%
99
99
Indoor Noise
dB-A (H/L)
48-48 / 44-44
Power Level dB
64 / 64
Outdoor Noise
dB-A (H/L)
55 / 55
Power Level dB
71 / 71
Max Current (A) / Max Input Power (W)
16.4 / 3.45k
Starting Current (A)
40
Compressor
Type
Hermetic motor
Motor Type
Induction (2-poles)
Output Power
W
2.4k
Indoor
Fan
Type
Cross-flow Fan
Material
ASG30K1
Motor Type
DC Motor
Input Power
W
94.8 - 94.8
Output Power
W
40
Speed
Lo
rpm
Cooling: 1250 - 1250
Heating: 1330 - 1330
Heating: 1330 - 1330
Me
rpm
Cooling: 1380 - 1380
Heating: 1380 - 1380
Heating: 1380 - 1380
Hi
rpm
Cooling: 1500 - 1500
Heating: 1540 - 1540
Heating: 1540 - 1540
SHi
rpm
Cooling: 1540 - 540
Out
d
oor F
a
n
Type
Propeller Fan
Material
PP
Motor Type
Induction (6-poles)
Input Power
W
163.1
Output Power
W
80
Speed
Lo
rpm
490 - 520
Hi
rpm
855 - 870
Moisture Removal
L/h (Pt/h)
4.7 (9.9)
6
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35
qC Dry Bulb (95qF Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry
Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Specifications are subjected to change without prior notice for further improvement.
Indoor Airflow
Lo
m
3
/min (ft
3
/m)
Cooling: 16.5 (583) - 16.5 (583)
Heating: 17.6 (622) - 17.6 (622)
Heating: 17.6 (622) - 17.6 (622)
Me
m
3
/min (ft
3
/m)
Cooling: 18.2 (643) - 18.2 (643)
Heating: 18.3 (646) - 18.3 (646)
Heating: 18.3 (646) - 18.3 (646)
Hi
m
3
/min (ft
3
/m)
Cooling: 19.8 (699) - 19.8 (699)
Heating: 20.4 (720) - 20.4 (720)
Heating: 20.4 (720) - 20.4 (720)
SHi
m
3
/min (ft
3
/m)
20.3 (718) - 20.3 (718)
Outdoor Airflow
Lo
m
3
/min (ft
3
/m)
30.1 (1060) - 32.0 (1130)
Hi
m
3
/min (ft
3
/m)
52.5 (1850) - 53.5 (1890)
Refrigeration Cycle
Control Device
Capillary Tube
Refrigerant Oil
cm
3
SUNISO 4GDID or ATMOS M60 or ATMOS 56M (900)
Refrigerant Type
g (oz)
R22, 2130 (75.2)
Dimension
Height (I/D / O/D)
mm (inch)
290 (11-7/16) / 750 (29-17/32)
Width (I/D / O/D)
mm (inch)
1070 (42-5/32) / 875 (34-15/32)
Depth (I/D / O/D)
mm (inch)
235 (9-9/32) / 345 (13-19/32)
Weight
Net (I/D / O/D)
kg (lb)
12 (27) / 66 (146)
P
iping
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4”) / 15.88 (5/8”)
Standard length
m (ft)
5 (16.4)
Length range (min~max)
m (ft)
3~30 (9.8~98.4)
I/D & O/D Height different
m (ft)
20.0 (65.6)
Additional Gas Amount
g/m (oz/ft)
30 (0.3)
Length for Additional Gas
m (ft)
7.5 (24.6)
Drain Hose
Inner Diameter
mm
12
Length
mm
560
Indoor Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row
u Stage u FPI
2
u 15 u 21
Size (W
u H u L)
mm
810
u 315 u 25.4
Outdoor Heat Exchanger
Fin Material
Aluminium (Blue Coat)
Fin Type
Corrugated Fin
Row
u Stage u FPI
2
u 28 u 17
Size (W
u H u L)
mm
810
u 315 u 25.4
44
u 711.2 u 802.4
836.4
Air Filter
Material
Polypropelene
Type
One-touch
Power Supply
Indoor Power Supply
Power Supply Cord
A
20
Thermostat
—
Protection Device
Inner Protector
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum
32
23
Minimum
16
11
Heating
Maximum
30
—
Minimum
16
—
Outdoor Operation Range
Cooling
Maximum
43
26
Minimum
16
11
Heating
Maximum
24
18
Minimum
-5
-6
7
3 Features
• E-ion Air Purifying System with Patrol Sensor
- Active e-ions are released to catch dust particles and bring them back the large positively charged filter.
- Patrol Sensor color changes to indicate the dirt level in the air.
- Patrol Sensor color changes to indicate the dirt level in the air.
• Long Installation Piping
- Long piping up to 30 meters.
• Easy to use remote control
• Quality Improvement
- Random auto restart after power failure for safety restart operation.
- Gas leakage protection.
- Prevent compressor reverse cycle.
- Inner protector to protect compressor.
- Noise prevention during soft dry operation.
- Blue coated condenser for high resistance to corrosion.
- Gas leakage protection.
- Prevent compressor reverse cycle.
- Inner protector to protect compressor.
- Noise prevention during soft dry operation.
- Blue coated condenser for high resistance to corrosion.
• Operation Improvement
- Quiet mode to reduce the indoor unit operating sound.
- Powerful mode to reach the desired room temperature quickly.
- 24-hour timer setting.
- Powerful mode to reach the desired room temperature quickly.
- 24-hour timer setting.
8
4 Location of Controls and Components
4.1.
Indoor Unit
4.2.
Outdoor Unit
4.3.
Remote Control
Click on the first or last page to see other CS-A28JKD / CU-A28JKD service manuals if exist.