DOWNLOAD LG WT1101CW Service Manual ↓ Size: 20.41 MB | Pages: 55 in PDF or view online for FREE

Model
WT1101CW
Pages
55
Size
20.41 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
wt1101cw.pdf
Date

LG WT1101CW Service Manual ▷ View online

33
ERROR
ERROR DECISION
BASIS
CAUSE FOR ERROR
OCCURRENCE
REMEDY
THERMISTOR
AC, MOTOR 
(CLUTCH 
MOTOR)
·
 Thermistor has a bad 
connection or failed
·
 AC motor has a bad 
connection or failed
· 
Clutching is failed 
-. Coupling get out of 
gear.
    -.Coupling is broken. 
·
 Check the connections at the 
Thermistor and at the WHITE 
3-pin connector at the main 
board
·
 Test thermistor to determine it is 
not detective 
· 
Check the connections at the 
AC motor and at the WHITE 
6-pin connector at the main 
board
· 
Test AC motor or coupling to 
determine it is not detective 
· 
Reseat the connector.
· Replace the thermistor if 
necessary.
·Reseat the connector.
· Replace the AC motor if 
necessary.
· Replace the coupling or Clutch 
housing if necessary.
34
DRAIN ERROR
Yes
Is OE displayed?
Reconnect or 
repair the 
connector
No
Is the connector connected to 
pump motor  assembly 
disconnected or 
disassembled? 
When you enter the SVC 
Mode, is the water level 
frequency below 26.0 kHz?
Drain pump
Connection connector
Yes
No
Is the coil of the drain pump 
too high or low? (resistance of 
the coil is 10-20 Ω)
Yes
Check the AIR 
CHAMBER, the 
tube (clogged), 
and press 
switch
Yes
Is the voltage between 
connectors out of range? 
(BL3 pin3)
- After remove Terminal  
Position Assurance
of connector, check as follows. 
 Pump running : 120V±5%
 Stopped Motor/Pump : 0~1V
 Method
1. Enter the SERVICE Mode.
2. Press START/PAUSE button.
  : 1 time  Main version   
  : 2 times Display version
  : 3 times  Inlet valve check mode
  : 4 times  Cold valve, bleach valve
  : 5 times  Rinse valve, hot valve
  : 6 times  Jet spray valve
  : 7 times  Heater check
  : 8 times  Alph check
  : 9 times  Pump check 
[Note] Environmental check list  
1) The drainage hose must not stay in a lower position
2)  The drainage hose must not be bent or clogged in any 
way due to the surrounding physical configuration
3) The drainage hose must not get frozen at all times.
4)  The drainage pump must not have any improper  
substance or material inside that may cause a 
machine breakdown.
Yes
No
Replace the 
DRAIN PUMP 
ASSEMBLY.
Replace the 
MAIN PCB
ASSEMBLY.
35
LOCKED MOTOR ERROR
Yes
Is LE displayed?
Reconnect
the connector
(connector /
wire / motor )
Check the connectors below. 
Is the connector  disconnected 
or disassembled? 
 (motor hall sensor connector, 
  motor drive connector)
  - Part of main PCB
    assembly (YL3, BL4)
Motor Drive
Hall Sensor
- Part of wire
Yes
No
No
Is rotor magnet cracked?
Is hall sensor out of order ? 
Yes
Yes
Check the IPM in the 
controller. Is IPM short?
Yes
No
Yes
Is the resistance values
in the range of 5 to15  Ω?
(U-V, V-W, W-V
:U=1, V=2, W=3)
-  After pull out the YL3 
connector, check the terminal 
of the connector in wire.
No
Replace the 
ROTOR
Replace the 
STATOR
Replace the Hall 
sensor
Replace the 
MAIN PCB 
ASSEMBLY
- Part of motor
Motor
Hall Sensor
Hall Sensor
Hall Sensor
Hall Sensor
Hall Sensor
Hall Sensor
Hall Sensor
Hall Sensor
Hall Sensor
Hall Sensor
Hall Sensor
Hall Sensor
Hall Sensor
Hall Sensor
Motor Drive
Motor Drive
Motor Drive
Motor Drive
Motor Drive
Motor Drive
Motor Drive
Motor Drive
Motor Drive
Motor Drive
Motor Drive
Motor Drive
Motor Drive
Motor Drive
Magnet
36
UNBALANCE ERROR
Yes
Is UE displayed?
Put laundry evenly 
In the DRUM 
assembly
No
Does the laundry lean toward 
one side, not evenly put in the 
DRUM assembly?
Is the washing machine 
installed at an angle?
Yes
Yes
Does the inlet valve work 
when the power is not 
applied?
Replace the INLET VALVE 
ASSEMBLY
No
Adjust the height of 
washing machine 
to be kept 
horizontally
Yes
If the inlet valve 
works 
continuously when 
the power is 
applied, replace 
the MAIN PCB 
ASSEMBLY
OVER FLOW ERROR
Yes
Is FE displayed?
Check the AIR 
CHAMBER and the 
tube (clogged).
Yes
When you enter the service 
mode, is the water level 
frequency over 21.0 kHz?
No
Page of 55
Display