LG WM3055CW Service Manual ▷ View online

36
LIQUID DETERGENT/SOFTENER/BLEACH DOES NOT FLOW IN
ABNORMAL SOUND
Refer to 
NO WATER SUPPLY
Check the wiring on the
dispenser.
Put it in the correct
compartment.
Clean the cap and
Container.
Secure the bolt.
Check hall sensor.
Replace If defective.
Then check stator.
Replace if necessary.
Check rotor for broken
magnets.
Replace rotor if necessary.
YES
NO
YES
YES
YES
YES
YES
NO
NO
NO
Is water supplied?
Are the plugs correctly connected to the terminals of
the INLET VALVE ASSEMBLY?
Is liquid detergent/softener/bleach put in the correct
compartment of the drawer?
Is the liquid detergent/softener/bleach cap clogged?
Is the motor bolt loosened?
Is there friction noise coming from the motor?
Z^
`U jvtwvulu{G{lz{punGpumvyth{pvu
`TXUGmps{lyGhzzltis€GOspulGmps{lyP
~Œ•GyŒšš›ˆ•ŠŒGOv”PGŠŒŠ’•ŽG›ŒGj–”—–•Œ•›SG‰ŒGšœ™ŒG›–G›œ™•G›ŒG—–žŒ™G–S
ˆ•‹G‹–G–“›ˆŽŒG‹šŠˆ™ŽŒGšœŠŒ•›“ U
~hyupun
j™Šœ›
‹ˆŽ™ˆ”
j™Šœ›G•G›ŒGthpuGw~iGVGj™Šœ›G‹ˆŽ™ˆ”
{Œš›
—–•›šG
ˆ•‹G
yŒšœ“›
{Œš›Gw–•›š
yŒšœ“›
~oGOXPG›–GykGOZP
~oGOZPG›–GykGOXP
WG˟
WG˟
OZP
OXP
~oX
OZP
OXP
ykX
38
9-2. DOOR LOCK SWITCH ASSEMBLY
Circuit
diagram
Circuit in the MAIN PWB / Circuit diagram
MAIN PWB
Vdc
Vac
MICOM
12V
12V
4
1
3
2
4
1
3
2
Relay
Relay
NA4
1
2
3
4
1
2
3
4
2
3
4
PTC
PTC
Door switch
SOLENOID
5
YL
BL
RD
BK
AC
Common
terminal
of Valve
Function
The Door Lock Switch Assembly consists of a Heating PTC, a Bimetal, a
Protection PTC, and a Solenoid. It locks the door during a wash cycle.
1. Operation for door closing
- After the system turns on, PTC heating starts up through terminal 2~4’s
authorizing the power on.
- After PTC heating starts up and before solenoid operation is driven,
force the system to the off position through CAM.
Door close
- Authorizing one impulse through terminal 3~4 (PTC & solenoid) will
make the door locked.
- Door lock is detected when switches in terminal 4~5 are set closed.
CAM rotation will forcibly clear off the connection. 
The maximum, allowable number of impulse authorizations is 2
Upon the third authorization of the impulse, 
the position of CAM goes back to the door-open position.
- Authorizing the impulse occurs in 4.5 seconds upon input for max
performance and two authorization processes are allowed at most.
Normal operation period of PTC heating: 1.5 - 5 seconds 
(Defects from the development process)
2. Operation for door opening
- With a temporary stop, door automatically opens by CAM rotations after
authorizing the impulse from the terminal 3 ~ 4 and the power turns off -
maximum of 3 times of the authorizing period 
- Upon the fourth authorization of the impulse, the position of CAM goes
back to the door-close position.
39
Test
points
Result
Test Points
(2) to (4)
(3) to (4)
(4) to (5)
(2) to (4)
Result
700-1500 1
60-90 1
Infinity
120 Vac
Remarks
At 77
°F 
(25
°C
)
At 77
°F 
(25
°C
)
Voltage Input
(2)
(3)
(4)
(5)
Page of 58