LG WM3001HPA Service Manual ▷ View online
60
DOOR
Open the door.
Unscrew the 4 screws from the hinge.
(Use the 8mm tool.)
DOOR LOCK SWITCH ASSEMBLY
Open the door and disassemble the CLAMP
ASSEMBLY.
Unscrew the 2 screws.
Disassemble the door upward.
NOTE
• Reconnect the connector after replacing
the DOOR SWITCH ASSEMBLY.
1
3
1
2
2
61
PUMP
Disassemble the cabinet cover.
Separate the pump hose, the bellows and the
circulation hose assembly from the pump
assembly.
Disassemble the pump assembly in arrow
direction.
HEATER
Disassemble the cabinet cover.
Separate 2 connectors from the heater.
Loosen the nut and pull out the heater.
THERMISTOR
Disassemble the cabinet cover.
Unplug the white connector from the
thermistor.
Pull it out by holding the bracket of the
thermistor.
CAUTION
• When assembling the heater, insert the
heater into the heater clip on the bottom of
the tub.
• Tighten the fastening nut so the heater is
secure.
CIRCULATION
HOSE
PUMP HOSE
BELLOWS
1
2
3
1
2
3
1
2
3
62
WHEN FOREIGN OBJECT IS STUCK BETWEEN DRUM AND TUB
Disassemble the cabinet cover.
Separate the heater from the tub.
Remove any foreign objects (wire, coin, etc.)
by inserting a long bar in the opening.
LAMP ASSEMBLY
Unscrew 2 screws on the back of the top plate.
Pull the top plate backward and upward as
shown.
TOP PLATE ASSEMBLY
1
2
3
1
Disconnect the connector.
3
Disassemble the lamp assembly.
4
2
63
MOTOR/DAMPER
NOTE
• If you pull the dampers apart, the must be
replaced. If you do not separate them, they
can be re-used.
Bolt
Rotor
DAMPER
HINGE,
DAMPER
Disassemble the back cover.
Remove the bolt.
Pull out the Rotor.
1
2
3
Unscrew the 2 screws from the tub bracket.
Remove the 6 bolts on the stator.
Unplug the 2 connectors from the stator.
1
2
3
Disassemble the damper hinges from the tub
and base.
1