4-5. DISASSEMBLY INSTRUCTION
Be sure to unplug the power to repair and
replace electric parts.
Asegúrese de hacer conexión a tierra para los
diagnósticos de problemas y reemplazo de partes.
Si no es posible, toque un cable a tierra con su
cuerpo para remover la desviación eléctrica entre
el cuerpo y el producto antes de trabajar.
PRECAUCIÓN POR ELECTROSTÁTICA
1) Disassembly of Front Panel 
& PCB Assembly
Remove two screw caps using a sharp tool
and two front panel fixing screws.
Push the front panel to the left side then
pull it out.
Disconnect the leads from the controller.
Remove 4 screw from the front panel.
Remove the PCB Assembly.
Fuse is located in the PCB assembly For fuse
replacement use the following rated fuse
* Rating of fuse
- 250V 6A fusing type for 220-240V product
- 125V 12A fusing type for 100-127V product 
leads
PCB Assembly
Fuse
34
2) Disassembly of Back Panel, Power
Cord, Inlet Valve & BP Sensor
Remove two back panel fixing screws in the
back side.
Disassemble the back panel.
Disconnect two connectors and disassemble
the power cord.
Remove a valve fixing screw & disconnect the
leads form the inlet valve.
Remove the inlet valve.
Disconnect the leads & the pressure tube from
the BP sensor.
Remove the BP sensor.
3) Disassembly of Lid Assembly,
Top Cover, Tub Cover, Pulsator
& Inner Tub
Remove Q-spring & two hinge pins then
disassemble the lid assembly
Remove two top cover fixing screws in the
rear then disassemble the top cover.
Remove tub cover fixing screws then
disassemble the tub cover.
Remove the pulsator fixing screw then
disassemble the pulsator.
Remove the hub fixing nut by a special tool.
Disassemble the inner tub.
 
 
   
 
Inlet valve
Power cord
BP sensor
Q-spring
Hinge Pin
Hinge Pin
35
4) Disassembly of Back Cover, Drain Pump,
Clutch(Transmission) & Motor
Remove back cover fixing screws then disassemble
the back cover.
Disconnect the leads and the drain hose-p from the
drain pump.
Remove the pump fixing screws then
disassemble the drain pump.
Fall down the washer for clutch & motor removal.
Remove the belt.
Disassemble the clutch.
Remove two motor fixing screws then
disassemble the motor.
5) Replacement of Damper asm
Separate top cover from washing machine.
As in the fig, lift snubber bar and take it out of out
case with out tub.
Damper assembly shall not be disassembled.
Replace damper as assembly.
For assembly, keep the following.(Location & color)
          
Location             P/No.            PIVOT(Color)
A051                NATURAL
A052                     BLUE
Tub cover
Inner tub
Hub fixing nut
Leads
Drain hose-p
Pump fixing screw
36
4-6. TEST RUNNING WITHOUT WATER
A)  WFT60A30(1)A(B,C) / WFT65A30(1)D(E,F) / WFT70A30(1)D(E,F)
WFT75A30(1)A(B) / WFT85A30(1)D(E) / WF-T75A30(1)A(B) / 
 To use the CHECK PROGRAM (QC TEST MODE), press WATER LEVEL, PROCESS and POWER button ON
without depositing any laundry.
 In QC TEST MODE all LEDs are on and press START(PAUSE) button to check over the following items.
NO CHECK METHOD
DISPLAY
CHECK ITEM
1
2
3
4
5
6
7
Initial state
Press once
Press twice
Press 3 times
Press 4 times
Press 5 times
Press 6 times
WATER LEVEL frequency is
on DISPLAY in the condition of
no water in TUB.
 After detecting laundry amount
the number of pulse is on the
DISPLAY.
 AUTO OFF.
 All LEDS ON.
64~70 DISPLAY.
 Laundry amount test.
 COLD water.
 HOT water. (option)
 If the LID is opened,            is on the
DISPLAY. In that case, close the LID.
 DRAIN MOTOR is 1st start.
 DRAIN MOTOR is 2nd start and drain
pump is on.
 All LEDS OFF.
WFT85A30(1)D(E) / WF-T65A31ED/ WF-T75B30AD / WF-T85B30TD
              WF-T85B31ED
 
Page of 64