DOWNLOAD LG WD14060D6 Service Manual ↓ Size: 17.55 MB | Pages: 67 in PDF or view online for FREE

Model
WD14060D6
Pages
67
Size
17.55 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
wd14060d6.pdf
Date

LG WD14060D6 Service Manual ▷ View online

49
9-5. INLET VALVE ASSEMBLY
      
   
 
Depending on the cycle and water temperature, the controller will energize the hot or cold
water valve solenoids to meet the selected water temperature.
After pull out the connector of defective valve, check the resistance.
Test points
(1)-(2)
Result
0.8-1.2 kΩ
 !
"#
"#
#
#
$ %
$ %
$ %
$ % !
#
&
'( 
%
)
&
)
%
$
$
%
)
$
%
)
&
)
%
$
&
)
%
$
&
)
%
$
*+,
  
 
* All load circuits in wiring diagramare all the same.
*$, *%,
*$, *%,
*$, *%,
*$, *%,
50
10. DISASSEMBLY INSTRUCTIONS
Remove the power cord from the outlet before disassembling or repairing the unit.
1 Unscrew the screws on the top plate.
3 The cover(Inner) is disassembled.
2 The plate assembly(Top) is pulled back and
then upward in direction of arrow. 
1 Pull out the drawer and unscrew 2 screws.
2 Lift the side of the Control Panel Assembly and
pull it out 
1 Unscrew two screws.
2 Push out PANEL ASSEMBLY, CONTROL after
Push the hook below.
1 The PWB assembly(Display) is disconnected.
2 When 7 screws are unscrewed on the PWB
insulator and the PWB assembly(Display) is
disassembled from the PWB insulator.
CONTROL PANEL
Screws
Screws
Screws
Disassembly 3 connectors.
51
1 Disassembly lower cover assembly.
2 Two screws are unscrewed.
3 Pull the PWB assembly in direstion of red
arrow.
4 Disassembly PWB like the picture.
PWB ASSEMBLY(MAIN)
1 The plate assembly(Top) is disassembled.
3 Unscrew two screws.
3 Two screws are unscrewed.
2 Pull the drawer  in direction of arrow.
4 Clamp
4 Clamp
5 Cutting cable ties and the ventillation hose
are disassembly on the dispenser
5 Cutting cable ties and the ventillation hose
are disassembly on the dispenser
DISPENSER ASSEMBLY
2 Pull the drawer to arrow direction.
2
1
52
VALVE     (STEAM) 
VALVE     (PRE-WASH)
VALVE     (NORMAL-WASH)
1 Disconnect the wiring connector.
1
1
2
3
2 Remove the valve by two screws of the valve
holder.
• Rating : 220/240V 50/60Hz
• Resistant : 3.5~4.5kΩ
2
When reconnecting the connector
1 Open the door completely.
2 Remove the two screws from the hinge.
When removing the Door Assembly, it is
necessary to hold the Bracket that is inner of
the Cabinet Cover.
First, prepare a bucket to put in the remained
water.
Drain from hose.
VIOLET/BLACK-BLACK
WHITE/BLACK-BLACK
GRAY/BLACK
INLET VALVE
3
DOOR
Removing method of remaining water
CAP(REMAING HOSE)
Page of 67
Display