DOWNLOAD LG WD-80192N / WD-80192SV Service Manual ↓ Size: 2.4 MB | Pages: 34 in PDF or view online for FREE

Model
WD-80192N WD-80192SV
Pages
34
Size
2.4 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
wd-80192n-wd-80192sv.pdf
Date

LG WD-80192N / WD-80192SV Service Manual ▷ View online

Checking Point
None
All lamps turn on
1 time
Clockwise spin (right)
Motor rpm (About 45)
2 times
Low speed Spin
Motor rpm (About 63~67)
3 times
High speed Spin
Motor rpm (About 79~85) : WD-80192S(N)(T)
Motor rpm (About 95~106) : WD-10192S(N)(T)
4 times
Inlet valve for pre-wash operation
Water level frequency (25~65)
5 times
Inlet valve for main-wash operation
Water level frequency (25~65)
Hot inlet valve in case of hot water fill
6 times
Inlet valve for main-wash operation 
Water level frequency (25~65)
7 times
Counterclockwise spin (left)
Motor rpm (About 45)
8 times
A Heater is in operation for 3 sec.
Water Temperature
9 times
Draining pump operation
Water level frequency
10 times
Auto off operation
7-1. BEFORE PERFORMING SERVICE
¡Æ
Be careful of electric shock or disconnecting the parts while troubleshooting.
¡Æ
Voltage of each terminal in 220-240V~ and DC while applying an electric current.
7-2. QC TEST MODE.  
¤
Pressing  Temp, and  Option button simultaneously.
¤Ł
Power supply ON with pressing upper two button.
¤Ø
Press the START/PAUSE button as follows.
¡a
Press the START/PAUSE button more 4 times until stop spinning
¡b
13
7-3.HOW TO KNOW THE WATER LEVEL FREQUENCY
Press the Spin and Temp. button simultaneously.
ex) 241 : Water level frequency = 241
10-1kHz
=24.1kHz
7. TROUBLESHOOTING
The digits means water level frequency (10
-1 
kHz) 
Pressing number of
START/PAUSE button
14
7-4.ERROR DISPLAY.
ERROR SYMPTOM
CAUSE
1
WATER INLET
Water has not reached to the pre-set level within 4 min. since
ERROR
inlet valve operated, or water has not reached to the normal
level within 25 min.
2
IMBALANCE
The appliance is tilted. 
ERROR
Laundry is gathered to one side.
Non distributable things are put into the drum.
3
DRAIN ERROR
Water has not drained enough within 5 min.
4
OVERFLOW
Water is automatically being pumped out because too much
ERROR
water is in the tub.
5
SENSOR PRESSURE
The sensor pressure switch is out of order.
S/W ERROR
6
DOOR OPEN
The 
[Start/Pause]
button is pressed with the door open.
ERROR
The door switch is out of order.
7
HEATING
ERROR
The thermistor is out of order
.
If you press the 
[Start/Pause]
button when an error is displayed, any error except S/W ERROR will disappear
and the machine will change into pause status.
In case of  
if the error is not resolved within 20 sec. In the case of other
errors, if the error is not resolved within 4 min. power will be turned off automatically and the error code will be
blinked. But in case of 
, power will not be turned off. 
,
,
,
15
8-1.DIAGNOSIS AND ANSWER FOR ABNORMAL OPERATION
8. ERROR DIAGNOSIS AND CHECK LIST
SYMPTOM
GUIDE FOR SERVICE CALL
NO POWER 
Water inlet trouble
YES
YES
YES
NO
NO
YES
NO
NO
Is the power plug connected firmly to 
220-240V~ outlet?
Power failure? or Breaker opened?
Is the outlet controlled by a switch.
Visit to check 
Is 
displayed?
Is the tap opened?
Is the tap frozen?
Is the water supply shut-off?
Is filter in the inlet valve clogged with foreign
material?
Visit to check 
Clean the filter of
inlet valve
16
SYMPTOM
GUIDE FOR SERVICE CALL
DOOR OPEN ERROR
Refer to 
7-3 ERROR DISPLAY
Drain Trouble
NO
YES
YES
NO
NO
YES
Did you press the Start/Pause button when
the door is open?
Visit to check
Check if the door switch is O.K 
Is 
displayed?
Is the debris filter clogged with foreign
material such as pins, coins, etc.?
Is the drain hose frozen with water, kinked, or
crushed?
Visit to check 
Close the door 
Clean up 
the filter. 
Page of 34
Display

Click on the first or last page to see other WD-80192N / WD-80192SV service manuals if exist.