LG WD-14350FD / WD-14351FD Service Manual ▷ View online
24
NO
YES
YES
YES
NO
NO
YES
NO
NO
YES
1
2
1
3 4
2
SPIN TROUBLE
Check the sensor
(Pressure) or hose
(Sensor). If the problem
is on the sensor or the
hose, replace the sensor
or the hose.
(Pressure) or hose
(Sensor). If the problem
is on the sensor or the
hose, replace the sensor
or the hose.
Normal
Correct the connector.
Correct the connector.
Replace the STATOR
ASSEMBLY
(4417EA1002D)
ASSEMBLY
(4417EA1002D)
Check on the spinning, is the frequency of the
water level 248 or more? The frequency can be
checked by pressing the Time Delay and Rinse+
buttons at the same time on the program.
water level 248 or more? The frequency can be
checked by pressing the Time Delay and Rinse+
buttons at the same time on the program.
When pressing Intensive, Rinse+ and POWER
buttons at the same time after power off, press the
Start/Pause button 2 times, is the drum low speed
spin?
buttons at the same time after power off, press the
Start/Pause button 2 times, is the drum low speed
spin?
Is it disconnected, or disassembled?
[White : 3pin( ), Red:3pin( ), Red:3pin( ),
Natural:4pin( )]
[White : 3pin( ), Red:3pin( ), Red:3pin( ),
Natural:4pin( )]
Is it disconnected, or disassembled?
[White:3pin ( ), White:5pin ( )]
[White:3pin ( ), White:5pin ( )]
Check the motor connector, Is the resistance of
the terminal same as the figure?
MOTOR TERMINAL (1)
Resistance of terminal:
About 5
10
Replace the MAIN PWB ASSEMBLY
25
Be sure to unplug the machine out of the outlet before disassembling and repairing the parts.
9. DISASSEMBLY INSTRUCTIONS
Unscrew 2 screws on the back of the top plate.
Pull the top plate backward and upward as shown.
Disconnect the ASSEMBLY connector.
Pull out the drawer and unscrew 2 screws.
Push 2 upper hooks down and pull the control panel.
Disconnect the PWB ASSEMBLY from the control
panel by unscrewing 7 screws.
Hook
Control Panel Assembly
Control Panel Assembly
CONTROL PANEL ASSEMBLY
Top Plate Assembly
26
Disassemble the TOP PLATE ASSEMBLY.
Pull out the drawer slightly upward.
Unscrew 2 screws.
Disassemble hose clamps and hoses.
Disassemble the ventilation bellows and the water inlet
bellows from the tub.
Option
PUSH
DISPENSER ASSEMBLY
DISPENSER ASSEMBLY
DRAWER
27
Disconnect the wiring connector.
Unscrew 2 screws from the back.
Unscrew 2 screws from the back.
When reconnecting the connector
Cold only model
Cold and Hot model
Open the lower cover CAP by using coin and pull out
the lower cover in the arrow direction after a screw is
unscrewed.
unscrewed.
1
2
3 Option
INLET VALVE ASSEMBLY
LOWER COVER
VALVE#1 (MAIN)
Whited/Black-Black
VALVE#2 (PRE)
Gray/ White - Black
VALVE #1 (MAIN)
Whited/Black-Black
VALVE #2 (PRE)
Gray/ White - Black
VALVE #3 (HOT)
Blue/Red - Black
Click on the first or last page to see other WD-14350FD / WD-14351FD service manuals if exist.